175 related articles for article (PubMed ID: 7480829)
1. A comparison of conventional 'forward planning' with inverse planning for 3D conformal radiotherapy of the prostate.
Oldham M; Neal A; Webb S
Radiother Oncol; 1995 Jun; 35(3):248-62. PubMed ID: 7480829
[TBL] [Abstract][Full Text] [Related]
2. The optimisation of wedge filters in radiotherapy of the prostate.
Oldham M; Neal AJ; Webb S
Radiother Oncol; 1995 Dec; 37(3):209-20. PubMed ID: 8746589
[TBL] [Abstract][Full Text] [Related]
3. Radiotherapy of prostate cancer with or without intensity modulated beams: a planning comparison.
De Meerleer GO; Vakaet LA; De Gersem WR; De Wagter C; De Naeyer B; De Neve W
Int J Radiat Oncol Biol Phys; 2000 Jun; 47(3):639-48. PubMed ID: 10837946
[TBL] [Abstract][Full Text] [Related]
4. The optimization and inherent limitations of 3D conformal radiotherapy treatment plans of the prostate.
Oldham M; Webb S
Br J Radiol; 1995 Aug; 68(812):882-93. PubMed ID: 7551787
[TBL] [Abstract][Full Text] [Related]
5. Improvements in prostate radiotherapy from the customization of beam directions.
Rowbottom CG; Webb S; Oldham M
Med Phys; 1998 Jul; 25(7 Pt 1):1171-9. PubMed ID: 9682202
[TBL] [Abstract][Full Text] [Related]
6. Algorithm and performance of a clinical IMRT beam-angle optimization system.
Djajaputra D; Wu Q; Wu Y; Mohan R
Phys Med Biol; 2003 Oct; 48(19):3191-212. PubMed ID: 14579860
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy.
Lee EK; Fox T; Crocker I
Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):301-20. PubMed ID: 16289912
[TBL] [Abstract][Full Text] [Related]
8. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans.
Bazalova-Carter M; Qu B; Palma B; HÃ¥rdemark B; Hynning E; Jensen C; Maxim PG; Loo BW
Med Phys; 2015 May; 42(5):2615-25. PubMed ID: 25979053
[TBL] [Abstract][Full Text] [Related]
9. Comparison of treatment techniques for conformal radiotherapy of the prostate using dose-volume histograms and normal tissue complication probabilities.
Neal AJ; Oldham M; Dearnaley DP
Radiother Oncol; 1995 Oct; 37(1):29-34. PubMed ID: 8539454
[TBL] [Abstract][Full Text] [Related]
10. Comparison of simulated annealing algorithms for conformal therapy treatment planning.
Rosen II; Lam KS; Lane RG; Langer M; Morrill SM
Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1091-9. PubMed ID: 7493835
[TBL] [Abstract][Full Text] [Related]
11. The comparison of radiotherapy techniques for treatment of the prostate cancer: the three-field vs. the four-field.
Milecki P; Piotrowski T; Dymnicka M
Neoplasma; 2004; 51(1):64-9. PubMed ID: 15004663
[TBL] [Abstract][Full Text] [Related]
12. A case study comparing the relative benefit of optimizing beam weights, wedge angles, beam orientations and tomotherapy in stereotactic radiotherapy of the brain.
Oldham M; Khoo VS; Rowbottom CG; Bedford JL; Webb S
Phys Med Biol; 1998 Aug; 43(8):2123-46. PubMed ID: 9725594
[TBL] [Abstract][Full Text] [Related]
13. Benefit of using biologic parameters (EUD and NTCP) in IMRT optimization for treatment of intrahepatic tumors.
Thomas E; Chapet O; Kessler ML; Lawrence TS; Ten Haken RK
Int J Radiat Oncol Biol Phys; 2005 Jun; 62(2):571-8. PubMed ID: 15890602
[TBL] [Abstract][Full Text] [Related]
14. A framework for inverse planning of beam-on times for 3D small animal radiotherapy using interactive multi-objective optimisation.
Balvert M; van Hoof SJ; Granton PV; Trani D; den Hertog D; Hoffmann AL; Verhaegen F
Phys Med Biol; 2015 Jul; 60(14):5681-98. PubMed ID: 26147184
[TBL] [Abstract][Full Text] [Related]
15. Dosimetry and radiobiologic model comparison of IMRT and 3D conformal radiotherapy in treatment of carcinoma of the prostate.
Luxton G; Hancock SL; Boyer AL
Int J Radiat Oncol Biol Phys; 2004 May; 59(1):267-84. PubMed ID: 15093924
[TBL] [Abstract][Full Text] [Related]
16. Interactively exploring optimized treatment plans.
Rosen I; Liu HH; Childress N; Liao Z
Int J Radiat Oncol Biol Phys; 2005 Feb; 61(2):570-82. PubMed ID: 15667980
[TBL] [Abstract][Full Text] [Related]
17. Particle swarm optimizer for weighting factor selection in intensity-modulated radiation therapy optimization algorithms.
Yang J; Zhang P; Zhang L; Shu H; Li B; Gui Z
Phys Med; 2017 Jan; 33():136-145. PubMed ID: 28089602
[TBL] [Abstract][Full Text] [Related]
18. Computerized design of target margins for treatment uncertainties in conformal radiotherapy.
Mageras GS; Fuks Z; Leibel SA; Ling CC; Zelefsky MJ; Kooy HM; van Herk M; Kutcher GJ
Int J Radiat Oncol Biol Phys; 1999 Jan; 43(2):437-45. PubMed ID: 10030273
[TBL] [Abstract][Full Text] [Related]
19. Clinical implementation of intensity-modulated arc therapy.
Yu CX; Li XA; Ma L; Chen D; Naqvi S; Shepard D; Sarfaraz M; Holmes TW; Suntharalingam M; Mansfield CM
Int J Radiat Oncol Biol Phys; 2002 Jun; 53(2):453-63. PubMed ID: 12023150
[TBL] [Abstract][Full Text] [Related]
20. The implementation of an advanced treatment planning algorithm in the treatment of lung cancer with conventional radiotherapy.
Pearson M; Atherton P; McMenemin R; McDonald F; Mazdai G; Mulvenna P; Lambert G
Clin Oncol (R Coll Radiol); 2009 Apr; 21(3):168-74. PubMed ID: 19162457
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]