These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 7484121)

  • 1. Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients.
    Malchau H; Kärrholm J; Wang YX; Herberts P
    Acta Orthop Scand; 1995 Oct; 66(5):418-24. PubMed ID: 7484121
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Accuracy of hip stem migration measurement on plain radiographs: reliability of bony and prosthetic landmarks].
    Bieger R; Cakir B; Reichel H; Kappe T
    Orthopade; 2014 Oct; 43(10):934-9. PubMed ID: 25223758
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Model-based roentgen stereophotogrammetric analysis using elementary geometrical shape models: 10 years results of an uncemented acetabular cup component.
    Jacobsen A; Seehaus F; Hong Y; Cao H; Schuh A; Forst R; Sesselmann S
    BMC Musculoskelet Disord; 2018 Sep; 19(1):335. PubMed ID: 30223820
    [TBL] [Abstract][Full Text] [Related]  

  • 4. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.
    Digas G
    Acta Orthop Suppl; 2005 Feb; 76(315):3-82. PubMed ID: 15790289
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Inter- and intraobserver study of radiographic assessment of cemented total hip arthroplasties.
    Kramhøft M; Gehrchen PM; Bødtker S; Wagner A; Jensen F
    J Arthroplasty; 1996 Apr; 11(3):272-6. PubMed ID: 8713905
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cemented versus uncemented socket in hip arthroplasty. A radiostereometric study of 60 randomized hips followed for 2 years.
    Onsten I; Carlsson AS
    Acta Orthop Scand; 1994 Oct; 65(5):517-21. PubMed ID: 7801753
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Movement patterns of the C-stem femoral component: an RSA study of 33 primary total hip arthroplasties followed for two years.
    Sundberg M; Besjakov J; von Schewelow T; Carlsson A
    J Bone Joint Surg Br; 2005 Oct; 87(10):1352-6. PubMed ID: 16189306
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Good diagnostic performance of early migration as a predictor of late aseptic loosening of acetabular cups: results from ten years of follow-up with Roentgen stereophotogrammetric analysis (RSA).
    Nieuwenhuijse MJ; Valstar ER; Kaptein BL; Nelissen RG
    J Bone Joint Surg Am; 2012 May; 94(10):874-80. PubMed ID: 22617914
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prediction of clinical outcome of THR from migration measurements on standard radiographs. A study of cemented Charnley and Stanmore femoral stems.
    Walker PS; Mai SF; Cobb AG; Bentley G; Hua J
    J Bone Joint Surg Br; 1995 Sep; 77(5):705-14. PubMed ID: 7559694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radiostereometry of hip prostheses. Review of methodology and clinical results.
    Kärrholm J; Herberts P; Hultmark P; Malchau H; Nivbrant B; Thanner J
    Clin Orthop Relat Res; 1997 Nov; (344):94-110. PubMed ID: 9372762
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interest of short implants in hip arthroplasty for osteonecrosis of the femoral head: comparative study "uncemented short" vs "cemented conventional" femoral stems.
    Miladi M; Villain B; Mebtouche N; Bégué T; Aurégan JC
    Int Orthop; 2018 Jul; 42(7):1669-1674. PubMed ID: 29761221
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of two digital radiostereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom.
    Bragdon CR; Estok DM; Malchau H; Kärrholm J; Yuan X; Bourne R; Veldhoven J; Harris WH
    J Orthop Res; 2004 May; 22(3):659-64. PubMed ID: 15099649
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Loosening of the cemented hip prosthesis. The importance of heat injury.
    Mjöberg B
    Acta Orthop Scand Suppl; 1986; 221():1-40. PubMed ID: 3468743
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Wristing -- a new opportunity in digital migration analysis of uncemented total hip arthroplasty].
    Schönrath F; Hein W; Klima S; Bach A
    Z Orthop Ihre Grenzgeb; 2005; 143(4):431-7. PubMed ID: 16118759
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early Subsidence Predicts Failure of a Cemented Femoral Stem With Minor Design Changes.
    Johanson PE; Antonsson M; Shareghi B; Kärrholm J
    Clin Orthop Relat Res; 2016 Oct; 474(10):2221-9. PubMed ID: 27188836
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Radiological study of the migration of prosthetic implants following hip arthroplasty].
    Lemaire R; Rodriguez A
    Acta Orthop Belg; 1996; 62 Suppl 1():124-31. PubMed ID: 9148637
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The accuracy of measurements of femoral neck fractures. Conventional radiography versus roentgen stereophotogrammetric analysis.
    Ragnarsson JI; Eliasson P; Kärrholm J; Lundström B
    Acta Orthop Scand; 1992 Apr; 63(2):152-6. PubMed ID: 1590049
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mid-term migration of a cemented total hip replacement assessed by radiostereometric analysis.
    Alfaro-Adrian J; Gill HS; Marks BE; Murray DW
    Int Orthop; 1999; 23(3):140-4. PubMed ID: 10486023
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical evaluation of model-based radiostereometric analysis to measure femoral head penetration and cup migration in four different cup designs.
    Shareghi B; Johanson PE; Kärrholm J
    J Orthop Res; 2017 Apr; 35(4):760-767. PubMed ID: 26825861
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiographic assessment of cup migration in bipolar hip arthroplasty: intra-observer and interobserver errors and tolerance limits.
    Middha VP; Singhal K
    Arch Orthop Trauma Surg; 1992; 111(4):230-1. PubMed ID: 1622715
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.