  • 1. Digital sensory loss without pulse oximeter malfunction.
    Donahue PJ; Emery S
    Anesth Analg; 1995 Dec; 81(6):1312. PubMed ID: 7486129
    [No Abstract]   [Full Text] [Related]  

  • 2. Sensory loss of the distal phalanx caused by pulse oximeter probe.
    Clark M; Lavies NG
    Anaesthesia; 1997 May; 52(5):508-9. PubMed ID: 9165987
    [No Abstract]   [Full Text] [Related]  

  • 3. Ischemic digital skin necrosis: a complication of the reusable Nelcor pulse oximeter probe.
    Berge KH; Lanier WL; Scanlon PD
    Anesth Analg; 1988 Jul; 67(7):712-3. PubMed ID: 3382049
    [No Abstract]   [Full Text] [Related]  

  • 4. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sensory loss of the distal phalanx and pulse oximeter probe.
    Gates RE; Kinsella SB; Moorthy SS
    Anesth Analg; 1995 Apr; 80(4):855. PubMed ID: 7893061
    [No Abstract]   [Full Text] [Related]  

  • 6. Digital injury from a pulse oximeter probe.
    Rubin MM; Ford HC; Sadoff RS
    J Oral Maxillofac Surg; 1991 Mar; 49(3):301-2. PubMed ID: 1995821
    [No Abstract]   [Full Text] [Related]  

  • 7. Design and evaluation of a new reflectance pulse oximeter sensor.
    Mendelson Y; Kent JC; Yocum BL; Birle MJ
    Med Instrum; 1988 Aug; 22(4):167-73. PubMed ID: 3173170
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Nellcor N-101 pulse oximeter. A clinical evaluation in anaesthesia and intensive care.
    Tytler JA; Seeley HF
    Anaesthesia; 1986 Mar; 41(3):302-5. PubMed ID: 3963334
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Management of pulse oximeter probe-induced finger injuries in children: report of two consecutive cases and review of the literature.
    Ceran C; Taner OF; Tekin F; Tezcan S; Tekin O; Civelek B
    J Pediatr Surg; 2012 Nov; 47(11):e27-9. PubMed ID: 23164026
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Digital nerve blocks can restore pulse oximeter signal detection.
    Bourke DL; Grayson RF
    Anesth Analg; 1991 Dec; 73(6):815-7. PubMed ID: 1952184
    [No Abstract]   [Full Text] [Related]  

  • 11. Misalignment of disposable pulse oximeter probes results in false saturation readings that influence anesthetic management.
    Guan Z; Baker K; Sandberg WS
    Anesth Analg; 2009 Nov; 109(5):1530-3. PubMed ID: 19843792
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Thermal injury with pulse oximeter probe in hypothermic patient. Pulse oximeter probe burn in hypothermia.
    Pandey CK; Rani A; Srivastava K; Baronia A; Agarwal A
    Can J Anaesth; 1999 Sep; 46(9):908-9. PubMed ID: 10490168
    [No Abstract]   [Full Text] [Related]  

  • 13. Burning of a neonate due to a pulse oximeter: arterial saturation monitoring.
    Sobel DB
    Pediatrics; 1992 Jan; 89(1):154-5. PubMed ID: 1345801
    [No Abstract]   [Full Text] [Related]  

  • 14. Exposed connections in pulse oximeter sensors can cause electrochemical burns.
    Health Devices; 2001 Dec; 30(12):456-7. PubMed ID: 11806182
    [No Abstract]   [Full Text] [Related]  

  • 15. [Use of pulse-type finger oximeter in anesthesia (author's transl)].
    Suzukawa M; Fujisawa M; Matsushita F; Suwa K; Yamamura H
    Masui; 1978 Jun; 27(6):600-5. PubMed ID: 660916
    [No Abstract]   [Full Text] [Related]  

  • 16. The OxiMax System. Nellcor's new platform for pulse oximetry.
    Mannheimer PD; Bebout DE
    Minerva Anestesiol; 2002 Apr; 68(4):236-9. PubMed ID: 12024089
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of a new reflectance oximeter with the Hewlett-Packard ear oximeter.
    Decker MJ; Dickensheets D; Arnold JL; Cheung PW; Strohl KP
    Biomed Instrum Technol; 1990; 24(2):122-6. PubMed ID: 2322755
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters.
    Choi SJ; Ahn HJ; Yang MK; Kim CS; Sim WS; Kim JA; Kang JG; Kim JK; Kang JY
    Acta Anaesthesiol Scand; 2010 Feb; 54(2):212-7. PubMed ID: 19719816
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A potential hazard with nondisposable pulse oximeter probes.
    Goodman E; Johnson PA
    Anesth Analg; 1999 Jul; 89(1):261. PubMed ID: 10389826
    [No Abstract]   [Full Text] [Related]  

  • 20. Modified Allen's test performed with a pulse oximeter--back to the future?
    Eipe N
    Acta Anaesthesiol Scand; 2007 May; 51(5):648-9. PubMed ID: 17430335