These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 7489795)
41. Impairment of ventilatory function and pulmonary gas exchange in non-smoking coalminers. Nemery B; Veriter C; Brasseur L; Frans A Lancet; 1987 Dec; 2(8573):1427-30. PubMed ID: 2891994 [TBL] [Abstract][Full Text] [Related]
43. [Spirometry in workers in a wheat-processing industry]. Corzo G; Naveda R Invest Clin; 1998 Sep; 39(3):175-87. PubMed ID: 9780552 [TBL] [Abstract][Full Text] [Related]
44. Can the evolution to pneumoconiosis be suspected in coal miners? A longitudinal study. Bourgkard E; Bernadac P; Chau N; Bertrand JP; Teculescu D; Pham QT Am J Respir Crit Care Med; 1998 Aug; 158(2):504-9. PubMed ID: 9700128 [TBL] [Abstract][Full Text] [Related]
45. Bronchodilator response of advanced lung function parameters depending on COPD severity. Jarenbäck L; Eriksson G; Peterson S; Ankerst J; Bjermer L; Tufvesson E Int J Chron Obstruct Pulmon Dis; 2016; 11():2939-2950. PubMed ID: 27932874 [TBL] [Abstract][Full Text] [Related]
46. Association of the forced oscillation technique with negative expiratory pressure in COPD. Akita T; Shirai T; Mori K; Shimoda Y; Suzuki T; Hayashi I; Noguchi R; Mochizuki E; Sakurai S; Saigusa M; Akamatsu T; Yamamoto A; Shishido Y; Morita S; Asada K; Suda T Respir Physiol Neurobiol; 2016 Jan; 220():62-8. PubMed ID: 26369446 [TBL] [Abstract][Full Text] [Related]
47. Dust exposure, respiratory symptoms, and longitudinal decline of lung function in young coal miners. Carta P; Aru G; Barbieri MT; Avataneo G; Casula D Occup Environ Med; 1996 May; 53(5):312-9. PubMed ID: 8673178 [TBL] [Abstract][Full Text] [Related]
48. High prevalence of reversible airway obstruction in asbestos-exposed workers. Delpierre S; Delvolgo-Gori MJ; Faucher M; Jammes Y Arch Environ Health; 2002; 57(5):441-5. PubMed ID: 12641187 [TBL] [Abstract][Full Text] [Related]
49. Transfer factor, lung volumes, resistance and ventilation distribution in healthy adults. Verbanck S; Van Muylem A; Schuermans D; Bautmans I; Thompson B; Vincken W Eur Respir J; 2016 Jan; 47(1):166-76. PubMed ID: 26585426 [TBL] [Abstract][Full Text] [Related]
50. Respiratory health effects of opencast coalmining: a cross sectional study of current workers. Love RG; Miller BG; Groat SK; Hagen S; Cowie HA; Johnston PP; Hutchison PA; Soutar CA Occup Environ Med; 1997 Jun; 54(6):416-23. PubMed ID: 9245948 [TBL] [Abstract][Full Text] [Related]
51. What does airway resistance tell us about lung function? Kaminsky DA Respir Care; 2012 Jan; 57(1):85-96; discussion 96-9. PubMed ID: 22222128 [TBL] [Abstract][Full Text] [Related]
52. Obstructive and restrictive spirometric patterns: fixed cut-offs for FEV1/FEV6 and FEV6. Vandevoorde J; Verbanck S; Schuermans D; Kartounian J; Vincken W Eur Respir J; 2006 Feb; 27(2):378-83. PubMed ID: 16452596 [TBL] [Abstract][Full Text] [Related]
53. A computational comparison of the multiple-breath washout and forced oscillation technique as markers of bronchoconstriction. Foy BH; Kay D Respir Physiol Neurobiol; 2017 Jun; 240():61-69. PubMed ID: 28300726 [TBL] [Abstract][Full Text] [Related]
54. Occupational dust exposure and smoking. Different effects on forced expiration and slope of the alveolar plateau. Rasmussen FV Eur J Respir Dis; 1985 Feb; 66(2):119-27. PubMed ID: 3972021 [TBL] [Abstract][Full Text] [Related]
55. Fixed ratio or lower limit of normal for the FEV Wollmer P; Frantz S; Engström G; Dencker M; Löfdahl CG; Nihlén U Clin Physiol Funct Imaging; 2017 May; 37(3):263-269. PubMed ID: 26443700 [TBL] [Abstract][Full Text] [Related]
56. Bronchodilator Responses in Respiratory Impedance, Hyperinflation and Gas Trapping in COPD. Milne S; Hammans C; Watson S; Farah CS; Thamrin C; King GG COPD; 2018; 15(4):341-349. PubMed ID: 29799289 [TBL] [Abstract][Full Text] [Related]
57. [Sensitivity and specificity of multi-frequency oscillation methods, body plethysmography and spirometry in 5-8-year-old asthmatic patients]. Buhr W; Reimnitz P; Jörres R; Berdel D Pneumologie; 1990 Oct; 44(10):1196-8. PubMed ID: 2281067 [TBL] [Abstract][Full Text] [Related]
58. Decline in annual lung function in workers exposed to asbestos with and without pre-existing fibrotic changes on chest radiography. Nakadate T Occup Environ Med; 1995 Jun; 52(6):368-73. PubMed ID: 7627312 [TBL] [Abstract][Full Text] [Related]
59. Respiratory system reactance as an indicator of the intrathoracic airway response to methacholine in children. Bouaziz N; Beyaert C; Gauthier R; Monin P; Peslin R; Marchal F Pediatr Pulmonol; 1996 Jul; 22(1):7-13. PubMed ID: 8856798 [TBL] [Abstract][Full Text] [Related]
60. Diagostic value of respiratory impedance measurements in elderly subjects. Janssens JP; Nguyen MC; Herrmann FR; Michel JP Respir Med; 2001 May; 95(5):415-22. PubMed ID: 11392585 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]