These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
190 related articles for article (PubMed ID: 7490164)
21. A maximum a posteriori probability expectation maximization algorithm for image reconstruction in emission tomography. Levitan E; Herman GT IEEE Trans Med Imaging; 1987; 6(3):185-92. PubMed ID: 18244020 [TBL] [Abstract][Full Text] [Related]
22. Acceleration of image-based resolution modelling reconstruction using an expectation maximization nested algorithm. Angelis GI; Reader AJ; Markiewicz PJ; Kotasidis FA; Lionheart WR; Matthews JC Phys Med Biol; 2013 Aug; 58(15):5061-83. PubMed ID: 23831633 [TBL] [Abstract][Full Text] [Related]
23. Fast maximum entropy approximation in SPECT using the RBI-MAP algorithm. Lalush DS; Frey EC; Tsui BM IEEE Trans Med Imaging; 2000 Apr; 19(4):286-94. PubMed ID: 10909924 [TBL] [Abstract][Full Text] [Related]
24. Conditional entropy maximization for PET image reconstruction using adaptive mesh model. Zhu H; Shu H; Zhou J; Dai X; Luo L Comput Med Imaging Graph; 2007 Apr; 31(3):166-77. PubMed ID: 17368841 [TBL] [Abstract][Full Text] [Related]
25. Ordered subsets Bayesian tomographic reconstruction using 2-D smoothing splines as priors. Lee SJ Comput Methods Programs Biomed; 2003 Sep; 72(1):27-42. PubMed ID: 12850295 [TBL] [Abstract][Full Text] [Related]
26. Maximum-entropy expectation-maximization algorithm for image reconstruction and sensor field estimation. Hong H; Schonfeld D IEEE Trans Image Process; 2008 Jun; 17(6):897-907. PubMed ID: 18482885 [TBL] [Abstract][Full Text] [Related]
27. Time of flight PET reconstruction using nonuniform update for regional recovery uniformity. Kim K; Kim D; Yang J; El Fakhri G; Seo Y; Fessler JA; Li Q Med Phys; 2019 Feb; 46(2):649-664. PubMed ID: 30508255 [TBL] [Abstract][Full Text] [Related]
28. A Novel Iterative MLEM Image Reconstruction Algorithm Based on Beltrami Filter: Application to ECT Images. Boudjelal A; Elmoataz A; Attallah B; Messali Z Tomography; 2021 Jul; 7(3):286-300. PubMed ID: 34449726 [TBL] [Abstract][Full Text] [Related]
29. [Tsallis entropy-based prior for PET reconstruction]. Gao Y; Lu L; Ma J; Bian Z; Lu Q; Cao L; Gao S Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2013 Jun; 30(3):455-9. PubMed ID: 23865299 [TBL] [Abstract][Full Text] [Related]
30. Noise properties of the EM algorithm: I. Theory. Barrett HH; Wilson DW; Tsui BM Phys Med Biol; 1994 May; 39(5):833-46. PubMed ID: 15552088 [TBL] [Abstract][Full Text] [Related]
31. Study and performance evaluation of statistical methods in image processing. Liang Z; Jaszczak R; Hart H Comput Biol Med; 1988; 18(6):395-408. PubMed ID: 3203501 [TBL] [Abstract][Full Text] [Related]
32. Acceleration of Expectation-Maximization algorithm for length-biased right-censored data. Chan KC Lifetime Data Anal; 2017 Jan; 23(1):102-112. PubMed ID: 27388910 [TBL] [Abstract][Full Text] [Related]
33. A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolution. Nuyts J; Fessler JA IEEE Trans Med Imaging; 2003 Sep; 22(9):1042-52. PubMed ID: 12956260 [TBL] [Abstract][Full Text] [Related]
34. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm. Li S; Zhang J; Krol A; Schmidtlein CR; Vogelsang L; Shen L; Lipson E; Feiglin D; Xu Y Med Phys; 2015 Aug; 42(8):4872-87. PubMed ID: 26233214 [TBL] [Abstract][Full Text] [Related]
35. A Bayesian approach for suppression of limited angular sampling artifacts in single particle 3D reconstruction. Moriya T; Acar E; Cheng RH; Ruotsalainen U J Struct Biol; 2015 Sep; 191(3):318-31. PubMed ID: 26193484 [TBL] [Abstract][Full Text] [Related]
36. Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography. Tanaka E; Kudo H Phys Med Biol; 2003 May; 48(10):1405-22. PubMed ID: 12812455 [TBL] [Abstract][Full Text] [Related]
37. Bayesian penalized-likelihood reconstruction algorithm suppresses edge artifacts in PET reconstruction based on point-spread-function. Yamaguchi S; Wagatsuma K; Miwa K; Ishii K; Inoue K; Fukushi M Phys Med; 2018 Mar; 47():73-79. PubMed ID: 29609821 [TBL] [Abstract][Full Text] [Related]
38. Investigation of maximum a posteriori probability expectation-maximization for image-based weighting spectral X-ray CT image reconstruction. Zhou Z; Xin R; Guan S; Li J; Tu J J Xray Sci Technol; 2018; 26(5):853-864. PubMed ID: 30124464 [TBL] [Abstract][Full Text] [Related]
39. Noise propagation for iterative penalized-likelihood image reconstruction based on Fisher information. Li Y Phys Med Biol; 2011 Feb; 56(4):1083-103. PubMed ID: 21263172 [TBL] [Abstract][Full Text] [Related]
40. Image reconstruction for positron emission tomography using fuzzy nonlinear anisotropic diffusion penalty. Zhu H; Shu H; Zhou J; Toumoulin C; Luo L Med Biol Eng Comput; 2006 Nov; 44(11):983-97. PubMed ID: 17061117 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]