These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

301 related articles for article (PubMed ID: 7493837)

  • 1. Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer.
    Lebesque JV; Bruce AM; Kroes AP; Touw A; Shouman RT; van Herk M
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1109-19. PubMed ID: 7493837
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Emptying the rectum before treatment delivery limits the variations of rectal dose - volume parameters during 3DCRT of prostate cancer.
    Stasi M; Munoz F; Fiorino C; Pasquino M; Baiotto B; Marini P; Malinverni G; Valdagni R; Gabriele P
    Radiother Oncol; 2006 Sep; 80(3):363-70. PubMed ID: 16959344
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anatomic variations due to radical prostatectomy. Impact on target volume definition and dose-volume parameters of rectum and bladder.
    Sanguineti G; Castellone P; Foppiano F; Franzone P; Marcenaro M; Tognoni P; Bolognesi A; Ceresoli GL; Fiorino C
    Strahlenther Onkol; 2004 Sep; 180(9):563-72. PubMed ID: 15378187
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Do differences in target volume definition in prostate cancer lead to clinically relevant differences in normal tissue toxicity?
    Livsey JE; Wylie JP; Swindell R; Khoo VS; Cowan RA; Logue JP
    Int J Radiat Oncol Biol Phys; 2004 Nov; 60(4):1076-81. PubMed ID: 15519777
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dose-wall histograms and normalized dose-surface histograms for the rectum: a new method to analyze the dose distribution over the rectum in conformal radiotherapy.
    Meijer GJ; van den Brink M; Hoogeman MS; Meinders J; Lebesque JV
    Int J Radiat Oncol Biol Phys; 1999 Nov; 45(4):1073-80. PubMed ID: 10571217
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of changes in bladder and rectal filling volume on organ motion and dose distribution of the bladder in radiotherapy for urinary bladder cancer.
    Fokdal L; Honoré H; Høyer M; Meldgaard P; Fode K; von der Maase H
    Int J Radiat Oncol Biol Phys; 2004 Jun; 59(2):436-44. PubMed ID: 15145160
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer.
    Wachter S; Gerstner N; Dorner D; Goldner G; Colotto A; Wambersie A; Pötter R
    Int J Radiat Oncol Biol Phys; 2002 Jan; 52(1):91-100. PubMed ID: 11777626
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Definition of prostatic contours using tomodensitometric slices: study of differences among radiotherapists and between examinations].
    Oozeer R; Chauvet B; Toy BJ; Berger C; Garcia R; Felix-Faure C; Le Thanh H; Reboul F
    Cancer Radiother; 1999; 3(4):333-40. PubMed ID: 10486545
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rectum contouring variability in patients treated for prostate cancer: impact on rectum dose-volume histograms and normal tissue complication probability.
    Fiorino C; Vavassori V; Sanguineti G; Bianchi C; Cattaneo GM; Piazzolla A; Cozzarini C
    Radiother Oncol; 2002 Jun; 63(3):249-55. PubMed ID: 12142088
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Associations between volume changes and spatial dose metrics for the urinary bladder during local versus pelvic irradiation for prostate cancer.
    Casares-Magaz O; Moiseenko V; Hopper A; Pettersson NJ; Thor M; Knopp R; Deasy JO; Muren LP; Einck J
    Acta Oncol; 2017 Jun; 56(6):884-890. PubMed ID: 28401808
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Patient positioning in prostate radiotherapy: is prone better than supine?
    Weber DC; Nouet P; Rouzaud M; Miralbell R
    Int J Radiat Oncol Biol Phys; 2000 May; 47(2):365-71. PubMed ID: 10802361
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of organ at risk definition on rectal dose-volume histograms in patients with prostate cancer undergoing external-beam radiotherapy.
    Boehmer D; Kuczer D; Badakhshi H; Stiefel S; Kuschke W; Wernecke KD; Budach V
    Strahlenther Onkol; 2006 May; 182(5):277-82. PubMed ID: 16673061
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy.
    Roeske JC; Forman JD; Mesina CF; He T; Pelizzari CA; Fontenla E; Vijayakumar S; Chen GT
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1321-9. PubMed ID: 7493857
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The potential for normal tissue dose reduction with neoadjuvant hormonal therapy in conformal treatment planning for stage C prostate cancer.
    Yang FE; Chen GT; Ray P; Vaida F; Chiru P; Hamilton RJ; Spelbring D; Abellera M; Vijayakumar S
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1009-17. PubMed ID: 7493827
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of treatment techniques for conformal radiotherapy of the prostate using dose-volume histograms and normal tissue complication probabilities.
    Neal AJ; Oldham M; Dearnaley DP
    Radiother Oncol; 1995 Oct; 37(1):29-34. PubMed ID: 8539454
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dose distribution in bladder and surrounding normal tissues in relation to bladder volume in conformal radiotherapy for bladder cancer.
    Majewski W; Wesolowska I; Urbanczyk H; Hawrylewicz L; Schwierczok B; Miszczyk L
    Int J Radiat Oncol Biol Phys; 2009 Dec; 75(5):1371-8. PubMed ID: 19467794
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modeling normal tissue complication probability from repetitive computed tomography scans during fractionated high-dose-rate brachytherapy and external beam radiotherapy of the uterine cervix.
    Dale E; Hellebust TP; Skjønsberg A; Høgberg T; Olsen DR
    Int J Radiat Oncol Biol Phys; 2000 Jul; 47(4):963-71. PubMed ID: 10863066
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery.
    Ghilezan M; Yan D; Liang J; Jaffray D; Wong J; Martinez A
    Int J Radiat Oncol Biol Phys; 2004 Dec; 60(5):1602-10. PubMed ID: 15590192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration.
    van Herk M; Bruce A; Kroes AP; Shouman T; Touw A; Lebesque JV
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1311-20. PubMed ID: 7493856
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of volume and location of irradiated rectum wall on rectal blood loss after radiotherapy of prostate cancer.
    Koper PC; Heemsbergen WD; Hoogeman MS; Jansen PP; Hart GA; Wijnmaalen AJ; van Os M; Boersma LJ; Lebesque JV; Levendag P
    Int J Radiat Oncol Biol Phys; 2004 Mar; 58(4):1072-82. PubMed ID: 15001247
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.