BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

311 related articles for article (PubMed ID: 7493847)

  • 1. Dosimetric evaluation of the conformation of the multileaf collimator to irregularly shaped fields.
    Frazier A; Du M; Wong J; Vicini F; Taylor R; Yu C; Matter R; Martinez A; Yan D
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1229-38. PubMed ID: 7493847
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of treatment setup variation on beam's eye view dosimetry for radiation therapy using the multileaf collimator vs. the cerrobend block.
    Frazier A; Yan D; Du M; Wong J; Vicini F; Matter R; Joyce M; Martinez A
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1247-56. PubMed ID: 7493849
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Dosimetric characterization of a multileaf collimator].
    Stasi M; Baiotto B; Palamara F; Gabriele P; Scielzo G
    Radiol Med; 1999 May; 97(5):382-8. PubMed ID: 10432971
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric evaluation and clinical application of virtual mini-multileaf collimator.
    Cheng CW; Wong JR; Ndlovu AM; Das IJ; Schiff P; Uematsu M
    Am J Clin Oncol; 2003 Jun; 26(3):e37-44. PubMed ID: 12796614
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The application of the multileaf collimator in radiotherapy: the dosimetric problems and the technical implications for its clinical use].
    Corvò R; Foppiano F; Orsatti M; Bisi F; Ghiso G; Martinelli R; Valanzola L; Vitale V
    Radiol Med; 1997 Nov; 94(5):512-9. PubMed ID: 9465218
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Physical-dosimetric characterization of a multi-leaf collimator system for clinical implementation in conformational radiotherapy].
    Pasquino M; Casanova Borca V; Tofani S
    Radiol Med; 2001 Mar; 101(3):187-92. PubMed ID: 11402959
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric assessment of the field abutment region in head and neck treatments using a multileaf collimator.
    Abdel-Hakim K; Nishimura T; Takaih M; Suzuki S; Sakahara H
    Strahlenther Onkol; 2003 May; 179(5):312-9. PubMed ID: 12740658
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intensity modulated radiation therapy with irregular multileaf collimated field: a dosimetric study on the penumbra region with different leaf stepping patterns.
    Chow JC; Grigorov GN; Jiang R
    Med Phys; 2006 Dec; 33(12):4606-13. PubMed ID: 17278813
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical implementation of a commercial multileaf collimator: dosimetry, networking, simulation, and quality assurance.
    Klein EE; Harms WB; Low DA; Willcut V; Purdy JA
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1195-208. PubMed ID: 7493844
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.
    Mavroidis P; Ferreira BC; Shi C; Lind BK; Papanikolaou N
    Phys Med Biol; 2007 Jul; 52(13):3817-36. PubMed ID: 17664579
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of multileaf-collimator and alloy-block field shaping.
    Galvin JM; Han K; Cohen R
    Int J Radiat Oncol Biol Phys; 1998 Feb; 40(3):721-31. PubMed ID: 9486625
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer.
    Steel J; Stewart A; Satory P
    Med Phys; 2009 Sep; 36(9):4244-9. PubMed ID: 19810498
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Study of dosimetric penumbra due to multileaf collimation on a medical linear accelerator.
    Sun J; Zhu Y
    Int J Radiat Oncol Biol Phys; 1995 Jul; 32(5):1409-17. PubMed ID: 7635781
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dosimetric effects on the penumbra region of irregular multi-leaf collimated fields.
    Chow JC; Wettlaufer B; Jiang R
    Phys Med Biol; 2006 Feb; 51(3):N31-8. PubMed ID: 16424573
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimizing leaf widths for a multileaf collimator.
    Cui W; Dai J
    Phys Med Biol; 2009 May; 54(10):3051-62. PubMed ID: 19398815
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.
    Kehwar TS; Bhardwaj AK; Chakarvarti SK
    J Appl Clin Med Phys; 2006 Aug; 7(3):43-54. PubMed ID: 17533348
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An experimental investigation into the radiation field offset of a dynamic multileaf collimator.
    Vial P; Oliver L; Greer PB; Baldock C
    Phys Med Biol; 2006 Nov; 51(21):5517-38. PubMed ID: 17047267
    [TBL] [Abstract][Full Text] [Related]  

  • 18. MLC leaf width impact on the clinical dose distribution: a Monte Carlo approach.
    Leal A; Sánchez-Doblado F; Arráns R; Capote R; Lagares JI; Pavón EC; Roselló J
    Int J Radiat Oncol Biol Phys; 2004 Aug; 59(5):1548-59. PubMed ID: 15275743
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID.
    Mohammadi M; Bezak E
    Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical dosimetry for implementation of a multileaf collimator.
    Boyer AL; Ochran TG; Nyerick CE; Waldron TJ; Huntzinger CJ
    Med Phys; 1992; 19(5):1255-61. PubMed ID: 1435606
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]