These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 7495666)

  • 1. Illi intracranial pressure monitoring and fixation device. A new fixation system for intracranial pressure monitoring in children and adolescents in paediatric neurotraumatology, hydrocephalus and craniofacial surgery.
    Renzulli P; Illi OE; Yonekawa Y; Grätz KW; Hönger M
    Pediatr Neurosurg; 1995; 23(1):54-6. PubMed ID: 7495666
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Usefulness of intracranial pressure measurement by Camino V420 system: preliminary report].
    Kotwica Z; Paciorek G
    Neurol Neurochir Pol; 1992; 26(5):671-6. PubMed ID: 1291905
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monitoring of brain tissue pressure with a fiberoptic device.
    Gambardella G; d'Avella D; Tomasello F
    Neurosurgery; 1992 Nov; 31(5):918-21; discussion 921-2. PubMed ID: 1436417
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical evaluation of the Codman microsensor intracranial pressure monitoring system.
    Fernandes HM; Bingham K; Chambers IR; Mendelow AD
    Acta Neurochir Suppl; 1998; 71():44-6. PubMed ID: 9779140
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases.
    Gelabert-González M; Ginesta-Galan V; Sernamito-García R; Allut AG; Bandin-Diéguez J; Rumbo RM
    Acta Neurochir (Wien); 2006 Apr; 148(4):435-41. PubMed ID: 16374566
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Telemetric Intracranial Pressure Monitoring with the Raumedic Neurovent P-tel.
    Antes S; Tschan CA; Heckelmann M; Breuskin D; Oertel J
    World Neurosurg; 2016 Jul; 91():133-48. PubMed ID: 27060515
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prolonged intracranial pressure (ICP) monitoring in non-traumatic pediatric neurosurgical diseases.
    Tamburrini G; Di Rocco C; Velardi F; Santini P
    Med Sci Monit; 2004 Apr; 10(4):MT53-63. PubMed ID: 15039654
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intracranial pressure monitoring in children: comparison of external ventricular device with the fiberoptic system.
    Gambardella G; Zaccone C; Cardia E; Tomasello F
    Childs Nerv Syst; 1993 Dec; 9(8):470-3. PubMed ID: 8124675
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of intracranial pressure monitoring in the management of childhood hydrocephalus and shunt-related problems.
    Fouyas IP; Casey AT; Thompson D; Harkness WF; Hayward RD
    Neurosurgery; 1996 Apr; 38(4):726-31; discussion 731-2. PubMed ID: 8692391
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Measuring intracranial pressure after trepanation in traumatized patients].
    Lopatecki M; Loritz T; Rudigier J
    Aktuelle Traumatol; 1993 Aug; 23(5):217-22. PubMed ID: 7901974
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Risk factors and complications of intracranial pressure monitoring with a fiberoptic device.
    Bekar A; Doğan S; Abaş F; Caner B; Korfali G; Kocaeli H; Yilmazlar S; Korfali E
    J Clin Neurosci; 2009 Feb; 16(2):236-40. PubMed ID: 19071023
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term testing of an intracranial pressure monitoring device.
    Kroin JS; McCarthy RJ; Stylos L; Miesel K; Ivankovich AD; Penn RD
    J Neurosurg; 2000 Nov; 93(5):852-8. PubMed ID: 11059668
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Non-invasive pressure monitoring in infants.
    Overweg-Plandsoen WC; de Jong DA; Avezaat CJ
    Eur J Pediatr Surg; 1992 Dec; 2 Suppl 1():38. PubMed ID: 1489748
    [No Abstract]   [Full Text] [Related]  

  • 14. Non-invasive ICP monitoring in infants: the Rotterdam Teletransducer revisited.
    Peters RJ; Hanlo PW; Gooskens RH; Braun KP; Tulleken CA; Willemse J
    Childs Nerv Syst; 1995 Apr; 11(4):207-13. PubMed ID: 7621481
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Measuring intracranial pressure].
    Pfenninger E
    Klin Anasthesiol Intensivther; 1994; 46():85-103. PubMed ID: 8065113
    [No Abstract]   [Full Text] [Related]  

  • 16. External Ventricular Drains versus Intraparenchymal Intracranial Pressure Monitors in Traumatic Brain Injury: A Prospective Observational Study.
    Liu H; Wang W; Cheng F; Yuan Q; Yang J; Hu J; Ren G
    World Neurosurg; 2015 May; 83(5):794-800. PubMed ID: 25541084
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new device for non-invasive measurements of intracranial pressure (ICP) in newborns.
    Peabody JL; Schneider H; Huch R; Huch A
    J Perinat Med; 1981; 9 Suppl 1():125-8. PubMed ID: 7229862
    [No Abstract]   [Full Text] [Related]  

  • 18. Clinical experience with a fiberoptic intracranial pressure monitor.
    Yablon JS; Lantner HJ; McCormack TM; Nair S; Barker E; Black P
    J Clin Monit; 1993 Jul; 9(3):171-5. PubMed ID: 8345369
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intracranial pressure monitoring techniques.
    Ghajar J
    New Horiz; 1995 Aug; 3(3):395-9. PubMed ID: 7496747
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Active singling out of shunt independence.
    Longatti PL; Carteri A
    Childs Nerv Syst; 1994 Jul; 10(5):334-6. PubMed ID: 7954503
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.