These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
101 related articles for article (PubMed ID: 7497029)
1. Evaluation of a portable clinical blood analyzer in the emergency department. Sands VM; Auerbach PS; Birnbaum J; Green M Acad Emerg Med; 1995 Mar; 2(3):172-8. PubMed ID: 7497029 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of a portable clinical analyzer in the pediatric emergency department: analysis of cost and turnaround time. Mainor BH; Hardwick WE; King WD South Med J; 2002 Jun; 95(6):634-8. PubMed ID: 12081219 [TBL] [Abstract][Full Text] [Related]
3. Point-of-care versus central laboratory testing: an economic analysis in an academic medical center. Tsai WW; Nash DB; Seamonds B; Weir GJ Clin Ther; 1994; 16(5):898-910; discussion 854. PubMed ID: 7859247 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a portable clinical analyzer in a veterinary hospital setting. Grosenbaugh DA; Gadawski JE; Muir WW J Am Vet Med Assoc; 1998 Sep; 213(5):691-4. PubMed ID: 9731265 [TBL] [Abstract][Full Text] [Related]
5. Precision, accuracy, and managed care implications of a hand-held whole blood analyzer in the prehospital setting. Tortella BJ; Lavery RF; Doran JV; Siegel JH Am J Clin Pathol; 1996 Jul; 106(1):124-7. PubMed ID: 8701922 [TBL] [Abstract][Full Text] [Related]
6. Impact of point-of-care testing on patients' length of stay in a large emergency department. Parvin CA; Lo SF; Deuser SM; Weaver LG; Lewis LM; Scott MG Clin Chem; 1996 May; 42(5):711-7. PubMed ID: 8653896 [TBL] [Abstract][Full Text] [Related]
7. Minimizing admission laboratory testing in trauma patients: use of a microanalyzer. Frankel HL; Rozycki GS; Ochsner MG; McCabe JE; Harviel JD; Jeng JC; Champion HR J Trauma; 1994 Nov; 37(5):728-36. PubMed ID: 7966469 [TBL] [Abstract][Full Text] [Related]
8. The evaluation of a portable clinical analyzer in the emergency department. Woo J; McCabe JB; Chauncey D; Schug T; Henry JB Am J Clin Pathol; 1993 Dec; 100(6):599-605. PubMed ID: 8249905 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer. Erickson KA; Wilding P Clin Chem; 1993 Feb; 39(2):283-7. PubMed ID: 8432019 [TBL] [Abstract][Full Text] [Related]
10. Impact from point-of-care devices on emergency department patient processing times compared with central laboratory testing of blood samples: a randomised controlled trial and cost-effectiveness analysis. Asha SE; Chan AC; Walter E; Kelly PJ; Morton RL; Ajami A; Wilson RD; Honneyman D Emerg Med J; 2014 Sep; 31(9):714-9. PubMed ID: 23748157 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of QBC Autoread performance in an emergency department setting. Paul RI; Badgett JT; Buchino JJ Pediatr Emerg Care; 1994 Dec; 10(6):359-63. PubMed ID: 7899125 [TBL] [Abstract][Full Text] [Related]
12. Point of care testing: randomised controlled trial of clinical outcome. Kendall J; Reeves B; Clancy M BMJ; 1998 Apr; 316(7137):1052-7. PubMed ID: 9552905 [TBL] [Abstract][Full Text] [Related]
13. [The i-STAT analyzer. A new, hand-held device for the bedside determination of hematocrit, blood gases, and electrolytes]. Schneider J; Dudziak R; Westphal K; Vettermann J Anaesthesist; 1997 Aug; 46(8):704-14. PubMed ID: 9382209 [TBL] [Abstract][Full Text] [Related]
14. A randomized trial to assess the efficacy of point-of-care testing in decreasing length of stay in a pediatric emergency department. Hsiao AL; Santucci KA; Dziura J; Baker MD Pediatr Emerg Care; 2007 Jul; 23(7):457-62. PubMed ID: 17666926 [TBL] [Abstract][Full Text] [Related]
15. Improving access to diagnostics: an evaluation of a satellite laboratory service in the emergency department. Leman P; Guthrie D; Simpson R; Little F Emerg Med J; 2004 Jul; 21(4):452-6. PubMed ID: 15208229 [TBL] [Abstract][Full Text] [Related]
16. Accuracy of bedside point of care testing in critical emergency department patients. McIntosh BW; Vasek J; Taylor M; Le Blanc D; Thode HC; Singer AJ Am J Emerg Med; 2018 Apr; 36(4):567-570. PubMed ID: 28918967 [TBL] [Abstract][Full Text] [Related]
17. Use of point-of-care testing and early assessment model reduces length of stay for ambulatory patients in an emergency department. Kankaanpää M; Raitakari M; Muukkonen L; Gustafsson S; Heitto M; Palomäki A; Suojanen K; Harjola VP Scand J Trauma Resusc Emerg Med; 2016 Oct; 24(1):125. PubMed ID: 27756354 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of a portable clinical analyzer for the determination of blood gas partial pressures, electrolyte concentrations, and hematocrit in venous blood samples collected from cattle, horses, and sheep. Peiró JR; Borges AS; Gonçalves RC; Mendes LC Am J Vet Res; 2010 May; 71(5):515-21. PubMed ID: 20433376 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital. Papadea C; Foster J; Grant S; Ballard SA; Cate JC; Southgate WM; Purohit DM Ann Clin Lab Sci; 2002; 32(3):231-43. PubMed ID: 12175085 [TBL] [Abstract][Full Text] [Related]
20. Implementation of an evidence based guideline reduces blood tests and length of stay for the limping child in a paediatric emergency department. McCanny PJ; McCoy S; Grant T; Walsh S; O'Sullivan R Emerg Med J; 2013 Jan; 30(1):19-23. PubMed ID: 22389351 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]