These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 7502285)

  • 1. Aortic bioprosthesis without early anticoagulation--risk of thromboembolism.
    Babin-Ebell J; Schmidt W; Eigel P; Elert O
    Thorac Cardiovasc Surg; 1995 Aug; 43(4):212-4. PubMed ID: 7502285
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is early anticoagulation with warfarin necessary after bioprosthetic aortic valve replacement?
    Sundt TM; Zehr KJ; Dearani JA; Daly RC; Mullany CJ; McGregor CG; Puga FJ; Orszulak TA; Schaff HV
    J Thorac Cardiovasc Surg; 2005 May; 129(5):1024-31. PubMed ID: 15867776
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experience with low-dose aspirin as thromboprophylaxis for the Tissuemed porcine aortic bioprosthesis: a survey of five years' experience.
    Goldsmith I; Lip GY; Mukundan S; Rosin MD
    J Heart Valve Dis; 1998 Sep; 7(5):574-9. PubMed ID: 9793859
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Early anticoagulation of bioprosthetic aortic valves in older patients: results from the Society of Thoracic Surgeons Adult Cardiac Surgery National Database.
    Brennan JM; Edwards FH; Zhao Y; O'Brien S; Booth ME; Dokholyan RS; Douglas PS; Peterson ED;
    J Am Coll Cardiol; 2012 Sep; 60(11):971-7. PubMed ID: 22921973
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Valvular bioprostheses and anticoagulation].
    Chambaz IC; Nendaz M
    Rev Med Suisse; 2008 Oct; 4(175):2198-202. PubMed ID: 19024573
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Thromboembolism with the Ionescu-Shiley bovine pericardial bioprosthesis. Long-term results (11 years)].
    González-Juanatey JR; Rubio Alvarez J; Sierra Quiroga J; Durán Muñoz D; Gil de la Peña M; García-Bengoechea JB
    Rev Esp Cardiol; 1990 Jan; 43(1):6-12. PubMed ID: 2315544
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low-dose oral anticoagulation in patients with mechanical heart valve prostheses: final report from the early self-management anticoagulation trial II.
    Koertke H; Zittermann A; Tenderich G; Wagner O; El-Arousy M; Krian A; Ennker J; Taborski U; Klövekorn WP; Moosdorf R; Saggau W; Koerfer R
    Eur Heart J; 2007 Oct; 28(20):2479-84. PubMed ID: 17890730
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Early anticoagulation after mechanical valve implantation, and related complications.
    Puri D; Kumar A; Basu R; Chaudhary A; Sarwal V; Sahoo M; Mahant TS
    J Heart Valve Dis; 2008 Jul; 17(4):418-24; discussion 425. PubMed ID: 18751472
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thrombotic and hemorrhagic complications in patients with mechanical heart valve prosthesis attending an anticoagulation clinic.
    Cortelazzo S; Finazzi G; Viero P; Galli M; Remuzzi A; Parenzan L; Barbui T
    Thromb Haemost; 1993 Apr; 69(4):316-20. PubMed ID: 8497842
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of anticoagulation regimens after Carpentier-Edwards aortic or mitral valve replacement.
    Blair KL; Hatton AC; White WD; Smith LR; Lowe JE; Wolfe WG; Young WG; Oldham HN; Douglas JM; Glower DD
    Circulation; 1994 Nov; 90(5 Pt 2):II214-9. PubMed ID: 7955256
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An eight-year experience with porcine bioprosthetic cardiac valves.
    Hartz RS; Fisher EB; Finkelmeier B; DeBoer A; Sanders JH; Moran JM; Michaelis LL
    J Thorac Cardiovasc Surg; 1986 Jun; 91(6):910-7. PubMed ID: 3713240
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Complications and risks associated with an anticoagulation therapy combining low molecular weight heparin and Warfarin after total replacement of large joints--our experience].
    Míka P; Behounek J; Skoták M; Nevsímal L
    Acta Chir Orthop Traumatol Cech; 2004; 71(4):237-44. PubMed ID: 15456102
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Antiplatelet therapy early after bioprosthetic aortic valve replacement is unnecessary in patients without thromboembolic risk factors.
    Brueck M; Kramer W; Vogt P; Steinert N; Roth P; Görlach G; Schönburg M; Heidt MC
    Eur J Cardiothorac Surg; 2007 Jul; 32(1):108-12. PubMed ID: 17449264
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A practical approach for bridging anticoagulation after mechanical heart valve replacement.
    Steger V; Bail DH; Graf D; Walker T; Rittig K; Ziemer G
    J Heart Valve Dis; 2008 May; 17(3):335-42. PubMed ID: 18592932
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Triflusal versus oral anticoagulation for primary prevention of thromboembolism after bioprosthetic valve replacement (trac): prospective, randomized, co-operative trial.
    Aramendi JI; Mestres CA; Martinez-León J; Campos V; Muñoz G; Navas C
    Eur J Cardiothorac Surg; 2005 May; 27(5):854-60. PubMed ID: 15848326
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Anticoagulation is unnecessary after biological aortic valve replacement.
    Moinuddeen K; Quin J; Shaw R; Dewar M; Tellides G; Kopf G; Elefteriades J
    Circulation; 1998 Nov; 98(19 Suppl):II95-8; discussion II98-9. PubMed ID: 9852888
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduction of mechanical heart valve thrombosis through a clinical audit.
    Bharat V; Das NK; Mohanty B; Jha AC; Chawla SC; Dash B; Mohanty R
    J Heart Valve Dis; 2003 May; 12(3):362-9. PubMed ID: 12803337
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Thrombotic risk in patients with aortic bioprostheses.
    Edmond JJ; Greaves SC; French JK; Graham KJ; Raudkivi PJ; Blake JW; Gerber IL; Smith WM
    J Heart Valve Dis; 2004 May; 13(3):525-8. PubMed ID: 15222303
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bioprosthetic versus mechanical prostheses for aortic valve replacement in the elderly.
    Davis EA; Greene PS; Cameron DE; Gott VI; Laschinger JC; Stuart RS; Sussman MS; Watkins L; Baumgartner WA
    Circulation; 1996 Nov; 94(9 Suppl):II121-5. PubMed ID: 8901731
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Unexpected findings concerning thromboembolic complications and anticoagulation after complete 10 year follow up of patients with St. Jude Medical prostheses.
    Horstkotte D; Schulte H; Bircks W; Strauer B
    J Heart Valve Dis; 1993 May; 2(3):291-301. PubMed ID: 8269122
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.