These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

319 related articles for article (PubMed ID: 7513406)

  • 1. Effect of biphasic waveform pulse on endocardial defibrillation efficacy in humans.
    Neuzner J; Pitschner HF; Huth C; Schlepper M
    Pacing Clin Electrophysiol; 1994 Feb; 17(2):207-12. PubMed ID: 7513406
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Combination biphasic waveform plus sequential pulse defibrillation improves defibrillation efficacy of a nonthoracotomy lead system.
    Exner D; Yee R; Jones DL; Klein GJ; Mehra R
    J Am Coll Cardiol; 1994 Feb; 23(2):317-22. PubMed ID: 8294680
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of biphasic and monophasic pulses: does the advantage of biphasic shocks depend on the waveshape?
    Natale A; Sra J; Krum D; Dhala A; Deshpande S; Jazayeri M; Axtell K; Degroot P; VanHout WL; Akhtar M
    Pacing Clin Electrophysiol; 1995 Jul; 18(7):1354-61. PubMed ID: 7567587
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical efficacy of shock waveforms and lead configurations for defibrillation.
    Jung W; Manz M; Moosdorf R; Spehl S; Wolpert C; Korte T; Lüderitz B
    Am Heart J; 1994 Apr; 127(4 Pt 2):985-93. PubMed ID: 8160603
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of monophasic and biphasic defibrillating pulse waveforms for transthoracic cardioversion. Biphasic Waveform Defibrillation Investigators.
    Greene HL; DiMarco JP; Kudenchuk PJ; Scheinman MM; Tang AS; Reiter MJ; Echt DS; Chapman PD; Jazayeri MR; Chapman FW
    Am J Cardiol; 1995 Jun; 75(16):1135-9. PubMed ID: 7762500
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biphasic waveforms for ventricular defibrillation: optimization of total pulse and second phase durations.
    Matula MH; Brooks MJ; Pan Q; Pless BD; Province RA; Echt DS
    Pacing Clin Electrophysiol; 1997 Sep; 20(9 Pt 1):2154-62. PubMed ID: 9309738
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Cardioverter-defibrillator implantations without thoracotomy: clinical experience with various electrode configurations and defibrillation wave forms of an endocardial/subcutaneous defibrillator system].
    Neuzner J; Huth C; Friedl A; Reinisch P; Pitschner HF; Schlepper M
    Z Kardiol; 1993 Feb; 82(2):99-107. PubMed ID: 8465572
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans.
    Bardy GH; Ivey TD; Allen MD; Johnson G; Mehra R; Greene HL
    J Am Coll Cardiol; 1989 Sep; 14(3):728-33. PubMed ID: 2768721
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Defibrillation efficacy of commercially available biphasic impulses in humans. Importance of negative-phase peak voltage.
    Tomassoni G; Newby K; Deshpande S; Axtell K; Sra J; Akhtar M; Natale A
    Circulation; 1997 Apr; 95(7):1822-6. PubMed ID: 9107169
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of defibrillation efficacy using biphasic waveforms delivered from various capacitances/pulse widths.
    Lin JH; Stotts LJ; Rosborough JP; Frederick H
    Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 2):158-62. PubMed ID: 9121981
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A prospective randomized comparison of defibrillation efficacy of truncated pulses and damped sine wave pulses in humans.
    Bardy GH; Zaghi H; Gartman D; Poole JE; Kudenchuk PK; Dolack GL; Johnson G; Troutman C
    J Cardiovasc Electrophysiol; 1994 Sep; 5(9):725-30. PubMed ID: 7827711
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Truncated biphasic pulses for transthoracic defibrillation.
    Bardy GH; Gliner BE; Kudenchuk PJ; Poole JE; Dolack GL; Jones GK; Anderson J; Troutman C; Johnson G
    Circulation; 1995 Mar; 91(6):1768-74. PubMed ID: 7882486
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization of biphasic waveforms for human nonthoracotomy defibrillation.
    Swartz JF; Fletcher RD; Karasik PE
    Circulation; 1993 Dec; 88(6):2646-54. PubMed ID: 8252675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prospective evaluation of the effect of biphasic waveform defibrillation on ventricular pacing thresholds.
    Kudenchuk PJ; Poole JE; Dolack GL; Gleva MJ; Anderson J; Troutman C; Bardy GH
    J Cardiovasc Electrophysiol; 1997 May; 8(5):485-95. PubMed ID: 9160224
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prospective comparison of biphasic and monophasic shocks for implantable cardioverter-defibrillators using endocardial leads.
    Saksena S; An H; Mehra R; DeGroot P; Krol RB; Burkhardt E; Mehta D; John T
    Am J Cardiol; 1992 Aug; 70(3):304-10. PubMed ID: 1632393
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biphasic waveform defibrillation using a three-electrode transvenous lead system in humans.
    Marks ML; Johnson G; Hofer BO; Bardy GH
    J Cardiovasc Electrophysiol; 1994 Feb; 5(2):103-8. PubMed ID: 8186880
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prospective randomized comparison in humans of biphasic waveform 60-microF and 120-microF capacitance pulses using a unipolar defibrillation system.
    Bardy GH; Poole JE; Kudenchuk PJ; Dolack GL; Mehra R; DeGroot P; Raitt MH; Jones GK; Johnson G
    Circulation; 1995 Jan; 91(1):91-5. PubMed ID: 7805224
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical experience with a new cardioverter defibrillator capable of biphasic waveform pulse and enhanced data storage: results of a prospective multicenter study. European Ventak P2 Investigator Group.
    Neuzner J
    Pacing Clin Electrophysiol; 1994 Jul; 17(7):1243-55. PubMed ID: 7937230
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Direct comparison of monophasic, biphasic and sequential pulse defibrillation over a single current pathway.
    Thakur R; Souza JJ; Chapman PD; Troup PJ; Wetherbee JN
    Can J Cardiol; 1996 Apr; 12(4):407-11. PubMed ID: 8608460
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveform.
    Winkle RA; Mead RH; Ruder MA; Gaudiani V; Buch WS; Pless B; Sweeney M; Schmidt P
    Am Heart J; 1989 Jan; 117(1):122-7. PubMed ID: 2911965
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.