127 related articles for article (PubMed ID: 7551301)
1. Internal defibrillation with smaller capacitors: a prospective randomized cross-over comparison of defibrillation efficacy obtained with 90-microF and 125-microF capacitors in humans.
Block M; Hammel D; Böcker D; Borggrefe M; Seifert T; Fastenrath C; Scheld HH; Breithardt G
J Cardiovasc Electrophysiol; 1995 May; 6(5):333-42. PubMed ID: 7551301
[TBL] [Abstract][Full Text] [Related]
2. Biphasic defibrillation using a single capacitor with large capacitance: reduction of peak voltages and ICD device size.
Block M; Hammel D; Böcker D; Borggrefe M; Budde T; Isbruch F; Scheld HH; Breithardt G
Pacing Clin Electrophysiol; 1996 Feb; 19(2):207-14. PubMed ID: 8834690
[TBL] [Abstract][Full Text] [Related]
3. A prospective randomized comparison in humans of biphasic waveform 60-microF and 120-microF capacitance pulses using a unipolar defibrillation system.
Bardy GH; Poole JE; Kudenchuk PJ; Dolack GL; Mehra R; DeGroot P; Raitt MH; Jones GK; Johnson G
Circulation; 1995 Jan; 91(1):91-5. PubMed ID: 7805224
[TBL] [Abstract][Full Text] [Related]
4. Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators.
Swerdlow CD; Kass RM; Chen PS; Hwang C; Raissi S
Circulation; 1994 Oct; 90(4):1840-6. PubMed ID: 7923670
[TBL] [Abstract][Full Text] [Related]
5. Short biphasic pulses from 90 microfarad capacitors lower defibrillation threshold.
Swerdlow CD; Kass RM; Davie S; Chen PS; Hwang C
Pacing Clin Electrophysiol; 1996 Jul; 19(7):1053-60. PubMed ID: 8823832
[TBL] [Abstract][Full Text] [Related]
6. Smaller capacitors improve the biphasic waveform.
Rist K; Tchou PJ; Mowrey K; Kroll MW; Brewer JE
J Cardiovasc Electrophysiol; 1994 Sep; 5(9):771-6. PubMed ID: 7827716
[TBL] [Abstract][Full Text] [Related]
7. New approach to biphasic waveforms for internal defibrillation: fully discharging capacitors.
Yamanouchi Y; Fishler MG; Mowrey KA; Wilkoff BL; Mazgalev TN; Tchou PJ
J Cardiovasc Electrophysiol; 2000 Aug; 11(8):907-12. PubMed ID: 10969754
[TBL] [Abstract][Full Text] [Related]
8. Clinical evaluation of defibrillation efficacy with a new single-capacitor biphasic waveform in patients undergoing implantation of an implantable cardioverter defibrillator.
Brugada J; Herse B; Sandsted B; Michel U; Schubert BD; Hahn SJ
Europace; 2001 Oct; 3(4):278-84. PubMed ID: 11678385
[TBL] [Abstract][Full Text] [Related]
9. Effect of shock waveform on relationship between upper limit of vulnerability and defibrillation threshold.
Swerdlow CD; Kass RM; O'Connor ME; Chen PS
J Cardiovasc Electrophysiol; 1998 Apr; 9(4):339-49. PubMed ID: 9581950
[TBL] [Abstract][Full Text] [Related]
10. Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system.
Poole JE; Bardy GH; Kudenchuk PJ; Dolack GL; Raitt MH; Mehra R; Johnson G
Pacing Clin Electrophysiol; 1995 Jul; 18(7):1369-73. PubMed ID: 7567589
[TBL] [Abstract][Full Text] [Related]
11. Optimizing defibrillation through improved waveforms.
Block M; Breithardt G
Pacing Clin Electrophysiol; 1995 Mar; 18(3 Pt 2):526-38. PubMed ID: 7777417
[TBL] [Abstract][Full Text] [Related]
12. Truncated biphasic pulses for transthoracic defibrillation.
Bardy GH; Gliner BE; Kudenchuk PJ; Poole JE; Dolack GL; Jones GK; Anderson J; Troutman C; Johnson G
Circulation; 1995 Mar; 91(6):1768-74. PubMed ID: 7882486
[TBL] [Abstract][Full Text] [Related]
13. Biphasic waveform defibrillation using a three-electrode transvenous lead system in humans.
Marks ML; Johnson G; Hofer BO; Bardy GH
J Cardiovasc Electrophysiol; 1994 Feb; 5(2):103-8. PubMed ID: 8186880
[TBL] [Abstract][Full Text] [Related]
14. Fully discharging phases. A new approach to biphasic waveforms for external defibrillation.
Yamanouchi Y; Brewer JE; Olson KF; Mowrey KA; Mazgalev TN; Wilkoff BL; Tchou PJ
Circulation; 1999 Aug; 100(8):826-31. PubMed ID: 10458718
[TBL] [Abstract][Full Text] [Related]
15. Defibrillation efficacy comparing a subcutaneous array electrode versus an "active can" implantable cardioverter defibrillator and a subcutaneous array electrode in addition to an "active can" implantable cardioverter defibrillator: results from active can versus array trials I and II.
Gradaus R; Block M; Seidl K; Brunn J; Isgro F; Hammel D; Hauer B; Breithardt G; Bocker D
J Cardiovasc Electrophysiol; 2001 Aug; 12(8):921-7. PubMed ID: 11513444
[TBL] [Abstract][Full Text] [Related]
16. A prospective randomized evaluation of implantable cardioverter-defibrillator size on unipolar defibrillation system efficacy.
Jones GK; Poole JE; Kudenchuk PJ; Dolack GL; Johnson G; DeGroot P; Gleva MJ; Raitt M; Bardy GH
Circulation; 1995 Nov; 92(10):2940-3. PubMed ID: 7586263
[TBL] [Abstract][Full Text] [Related]
17. Prospective randomized comparison of 50%/50% versus 65%/65% tilt biphasic waveform on defibrillation in humans.
Sweeney MO; Natale A; Volosin KJ; Swerdlow CD; Baker JH; Degroot P
Pacing Clin Electrophysiol; 2001 Jan; 24(1):60-5. PubMed ID: 11227971
[TBL] [Abstract][Full Text] [Related]
18. Effect of electrode configuration and capacitor size on internal atrial defibrillation threshold using leads currently used for ventricular defibrillation.
Neri R; Palermo P; Cesario AS; Baragli D; Amici E; Laudadio MT; De Rosa A; DeSeta F; Mongeon L; Gambelli G
J Interv Card Electrophysiol; 1999 Jul; 3(2):149-53. PubMed ID: 10387142
[TBL] [Abstract][Full Text] [Related]
19. Testing different biphasic waveforms and capacitances: effect on atrial defibrillation threshold and pain perception.
Tomassoni G; Newby KH; Kearney MM; Brandon MJ; Barold H; Natale A
J Am Coll Cardiol; 1996 Sep; 28(3):695-9. PubMed ID: 8772758
[TBL] [Abstract][Full Text] [Related]
20. Effect of changing capacitors between phases of a biphasic defibrillation shock.
Walcott GP; Rollins DL; Smith WM; Ideker RE
Pacing Clin Electrophysiol; 1996 Jun; 19(6):945-54. PubMed ID: 8774825
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]