27. Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms. Swerdlow CD; Fan W; Brewer JE Circulation; 1996 Nov; 94(9):2278-84. PubMed ID: 8901683 [TBL] [Abstract][Full Text] [Related]
28. Sawtooth first phase biphasic defibrillation waveform: a comparison with standard waveform in clinical devices. Yamanouchi Y; Brewer JE; Mowrey KA; Kroll MW; Donohoo AM; Wilkoff BL; Tchou PJ J Cardiovasc Electrophysiol; 1997 May; 8(5):517-28. PubMed ID: 9160228 [TBL] [Abstract][Full Text] [Related]
29. Prospective randomized comparison of 65%/65% versus 42%/42% tilt biphasic waveform on defibrillation thresholds in humans. Shepard RK; DeGroot PJ; Pacifico A; Wood MA; Ellenbogen KA J Interv Card Electrophysiol; 2003 Jun; 8(3):221-5. PubMed ID: 12815309 [TBL] [Abstract][Full Text] [Related]
30. Defibrillation thresholds are lower with smaller storage capacitors. Leonelli FM; Kroll MW; Brewer JE Pacing Clin Electrophysiol; 1995 Sep; 18(9 Pt 1):1661-5. PubMed ID: 7491309 [TBL] [Abstract][Full Text] [Related]
31. Ventricular defibrillation with triphasic waveforms. Huang J; KenKnight BH; Rollins DL; Smith WM; Ideker RE Circulation; 2000 Mar; 101(11):1324-8. PubMed ID: 10725294 [TBL] [Abstract][Full Text] [Related]
32. Large capacitor defibrillation waveform reduces peak voltages without increasing energies. Hahn SJ; Heil JE; Lang DJ Pacing Clin Electrophysiol; 1995 Jan; 18(1 Pt 2):203-7. PubMed ID: 7724400 [TBL] [Abstract][Full Text] [Related]
33. Defibrillation efficacy of commercially available biphasic impulses in humans. Importance of negative-phase peak voltage. Tomassoni G; Newby K; Deshpande S; Axtell K; Sra J; Akhtar M; Natale A Circulation; 1997 Apr; 95(7):1822-6. PubMed ID: 9107169 [TBL] [Abstract][Full Text] [Related]
34. [Influence of waveform and configuration of electrodes on the defibrillation threshold of implantable cardioverter-defibrillators]. Block M; Hammel D; Breithardt G Herzschrittmacherther Elektrophysiol; 1997 Mar; 8(1):15-31. PubMed ID: 19495674 [TBL] [Abstract][Full Text] [Related]
35. Does reducing capacitance have potential for further miniaturisation of implantable defibrillators? Alt E; Evans F; Wolf PD; Pasquantonio J; Stotts L; Heinz S; Schömig A Heart; 1997 Mar; 77(3):234-7. PubMed ID: 9093040 [TBL] [Abstract][Full Text] [Related]
36. Application of models of defibrillation to human defibrillation data: implications for optimizing implantable defibrillator capacitance. Swerdlow CD; Brewer JE; Kass RM; Kroll MW Circulation; 1997 Nov; 96(9):2813-22. PubMed ID: 9386143 [TBL] [Abstract][Full Text] [Related]
37. Optimization of biphasic waveforms for human nonthoracotomy defibrillation. Swartz JF; Fletcher RD; Karasik PE Circulation; 1993 Dec; 88(6):2646-54. PubMed ID: 8252675 [TBL] [Abstract][Full Text] [Related]