These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
102 related articles for article (PubMed ID: 7559715)
1. Changing crystallinity of polyethylene in the acetabular cups of Weller hip prostheses. Otfinowski J; Pawelec A J Bone Joint Surg Br; 1995 Sep; 77(5):802-5. PubMed ID: 7559715 [TBL] [Abstract][Full Text] [Related]
2. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions. Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821 [TBL] [Abstract][Full Text] [Related]
3. Impingement of acetabular cups in a hip simulator: comparison of highly cross-linked and conventional polyethylene. Holley KG; Furman BD; Babalola OM; Lipman JD; Padgett DE; Wright TM J Arthroplasty; 2005 Oct; 20(7 Suppl 3):77-86. PubMed ID: 16214007 [TBL] [Abstract][Full Text] [Related]
4. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator. McKellop HA; Shen FW; Campbell P; Ota T J Orthop Res; 1999 May; 17(3):329-39. PubMed ID: 10376720 [TBL] [Abstract][Full Text] [Related]
5. Structural profile of ultra-high molecular weight polyethylene in acetabular cups worn on hip simulators characterized by confocal Raman spectroscopy. Puppulin L; Kumakura T; Yamamoto K; Pezzotti G J Orthop Res; 2011 Jun; 29(6):893-9. PubMed ID: 21246621 [TBL] [Abstract][Full Text] [Related]
6. Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator. Taddei P; Affatato S; Fagnano C; Toni A Biomacromolecules; 2006 Jun; 7(6):1912-20. PubMed ID: 16768414 [TBL] [Abstract][Full Text] [Related]
7. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. McKellop H; Shen FW; Lu B; Campbell P; Salovey R J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831 [TBL] [Abstract][Full Text] [Related]
8. Surface-gradient cross-linked polyethylene acetabular cups: oxidation resistance and wear against smooth and rough femoral balls. Shen FW; McKellop H Clin Orthop Relat Res; 2005 Jan; (430):80-8. PubMed ID: 15662307 [TBL] [Abstract][Full Text] [Related]
9. Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant. Wang A Proc Inst Mech Eng H; 1998; 212(1):71-2; author reply 72-3. PubMed ID: 9529939 [No Abstract] [Full Text] [Related]
10. Comparison of polyethylene wear in machined versus molded polyethylene. Bankston AB; Keating EM; Ranawat C; Faris PM; Ritter MA Clin Orthop Relat Res; 1995 Aug; (317):37-43. PubMed ID: 7671494 [TBL] [Abstract][Full Text] [Related]
11. Impingement contributes to backside wear and screw-metallic shell fretting in modular acetabular cups. Kligman M; Furman BD; Padgett DE; Wright TM J Arthroplasty; 2007 Feb; 22(2):258-64. PubMed ID: 17275644 [TBL] [Abstract][Full Text] [Related]
12. A new approach for assessment of wear in metal-backed acetabular cups using computed tomography: a phantom study with retrievals. Jedenmalm A; Noz ME; Olivecrona H; Olivecrona L; Stark A Acta Orthop; 2008 Apr; 79(2):218-24. PubMed ID: 18484247 [TBL] [Abstract][Full Text] [Related]
13. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757 [TBL] [Abstract][Full Text] [Related]
14. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters. Digas G Acta Orthop Suppl; 2005 Feb; 76(315):3-82. PubMed ID: 15790289 [TBL] [Abstract][Full Text] [Related]
15. Failure of the Ring polyethylene uncemented acetabular cup. Harper GD; Bull T; Cobb AG; Bentley G J Bone Joint Surg Br; 1995 Jul; 77(4):557-61. PubMed ID: 7615597 [TBL] [Abstract][Full Text] [Related]
16. Loading of the acetabulum by polyethylene and all-ceramic inserts in metal-backed acetabular cups. Kummer FJ; Iesaka K; Rogers J; Di Cesare PE Bull Hosp Jt Dis; 2003; 61(3-4):132-4. PubMed ID: 15156812 [TBL] [Abstract][Full Text] [Related]
18. Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test. Affatato S; De Mattia JS; Bracco P; Pavoni E; Taddei P J Mech Behav Biomed Mater; 2016 Dec; 64():240-52. PubMed ID: 27522313 [TBL] [Abstract][Full Text] [Related]
19. The influence of the pelvic bone on the computational results of the acetabular component of a total hip prosthesis. Barreto S; Folgado J; Fernandes PR; Monteiro J J Biomech Eng; 2010 May; 132(5):054503. PubMed ID: 20459214 [TBL] [Abstract][Full Text] [Related]
20. Raman tensor analysis of ultra-high molecular weight polyethylene and its application to study retrieved hip joint components. Takahashi Y; Puppulin L; Zhu W; Pezzotti G Acta Biomater; 2010 Sep; 6(9):3583-94. PubMed ID: 20215056 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]