These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
89 related articles for article (PubMed ID: 7565366)
61. A Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography. Platten DJ J Radiol Prot; 2014 Jun; 34(2):445-56. PubMed ID: 24894101 [TBL] [Abstract][Full Text] [Related]
62. "Zero-field" dose data for 60Co and other high-energy photon beams in water. Nizin P; Qian GX; Rashid H Med Phys; 1993; 20(5):1353-60. PubMed ID: 8289716 [TBL] [Abstract][Full Text] [Related]
63. A convolution method for calculating 10-MV x-ray primary and scatter dose including electron contamination dose. Iwasaki A Med Phys; 1992; 19(4):907-15. PubMed ID: 1518479 [TBL] [Abstract][Full Text] [Related]
64. Two new experimental methods of calculating scatter fraction as a function of depth in scattering media: a comparison study. Knesaurek K Med Phys; 1992; 19(3):591-8. PubMed ID: 1508097 [TBL] [Abstract][Full Text] [Related]
65. Day's integration of scatter dose with an analytical expression. Brown LH; Svensson GK; Bjärngard BE Med Phys; 1981; 8(2):184-9. PubMed ID: 6798384 [TBL] [Abstract][Full Text] [Related]
66. Computer generation of high-energy x-ray dose distributions. Schulz RJ; McKiernan F; Agostinelli AG Med Phys; 1976; 3(1):12-8. PubMed ID: 815776 [TBL] [Abstract][Full Text] [Related]
67. A clinically operational method for three-dimensional dose calculations. Altschuler MD; Sontag MR; Bloch P Phys Med Biol; 1985 Mar; 30(3):217-28. PubMed ID: 3920686 [TBL] [Abstract][Full Text] [Related]
68. A photon dose distribution model employing convolution calculations. Boyer A; Mok E Med Phys; 1985; 12(2):169-77. PubMed ID: 4000072 [TBL] [Abstract][Full Text] [Related]
69. Scatter dose summation for irregular fields: speed and accuracy study. DeWyngaert JK; Siddon RL; Bjarngard BE Int J Radiat Oncol Biol Phys; 1986 May; 12(5):839-42. PubMed ID: 3710865 [TBL] [Abstract][Full Text] [Related]
70. A new approach to CT pixel-based photon dose calculations in heterogeneous media. Wong JW; Henkelman RM Med Phys; 1983; 10(2):199-208. PubMed ID: 6865860 [TBL] [Abstract][Full Text] [Related]
71. Tissue-air ratios and scatter-air ratios for diagnostic radiology (1-4 mm Al HVL). Harrison RM Phys Med Biol; 1983 Jan; 28(1):1-18. PubMed ID: 6828554 [TBL] [Abstract][Full Text] [Related]
72. Reconsideration of the power-law (Batho) equation for inhomogeneity corrections. Wong JW; Henkelman RM Med Phys; 1982; 9(4):521-30. PubMed ID: 7110083 [TBL] [Abstract][Full Text] [Related]
73. Tissue--air ratio, peak scatter factor and consistency. Henry WH Phys Med Biol; 1974 Jan; 19(1):43-50. PubMed ID: 4438443 [No Abstract] [Full Text] [Related]
74. A note on back-scatter and depth doses for elongated rectangular X-ray fields. JONES DE Br J Radiol; 1949 Jun; 22(258):342-5. PubMed ID: 18144938 [No Abstract] [Full Text] [Related]
75. Scatter-air ratios. Cunningham JR Phys Med Biol; 1972 Jan; 17(1):42-51. PubMed ID: 5071500 [No Abstract] [Full Text] [Related]
76. Output factors and scatter ratios. Chhabra AS Phys Med Biol; 1979 Jul; 24(4):822-4. PubMed ID: 472018 [No Abstract] [Full Text] [Related]