BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 7566533)

  • 1. A long-term complication of burying a shunt valve in the skull.
    Ammar A; Nasser M
    Neurosurg Rev; 1995; 18(1):65-7. PubMed ID: 7566533
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical complications of the reservoirs and flushing devices in ventricular shunt systems.
    Martinez-Lage JF; Poza M; Esteban JA
    Br J Neurosurg; 1992; 6(4):321-5. PubMed ID: 1388825
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multiloculated hydrocephalus related to cerebrospinal fluid shunt infection.
    Jamjoom AB; Mohammed AA; al-Boukai A; Jamjoom ZA; Rahman N; Jamjoom HT
    Acta Neurochir (Wien); 1996; 138(6):714-9. PubMed ID: 8836287
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Disconnection as a cause of ventriculoperitoneal shunt malfunction in multicomponent shunt systems.
    Aldrich EF; Harmann P
    Pediatr Neurosurg; 1990-1991; 16(6):309-11; discussion 312. PubMed ID: 2134742
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Shunt failure caused by valve collapse.
    Lundar T; Langmoen IA; Hovind KH
    J Neurol Neurosurg Psychiatry; 1991 Jun; 54(6):559-60. PubMed ID: 1880522
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neuroendoscopic procedures in achievement of shunt independence: outcome analysis of 28 patients with shunt malfunction.
    Sufianov A; Sufianova G; Iakimov Iu
    Minim Invasive Neurosurg; 2008 Jun; 51(3):158-64. PubMed ID: 18521787
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prevention of ventricular catheter obstruction and slit ventricle syndrome by the prophylactic use of the Integra antisiphon device in shunt therapy for pediatric hypertensive hydrocephalus: a 25-year follow-up study.
    Gruber RW; Roehrig B
    J Neurosurg Pediatr; 2010 Jan; 5(1):4-16. PubMed ID: 20043731
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus.
    Drake JM; Kestle JR; Milner R; Cinalli G; Boop F; Piatt J; Haines S; Schiff SJ; Cochrane DD; Steinbok P; MacNeil N
    Neurosurgery; 1998 Aug; 43(2):294-303; discussion 303-5. PubMed ID: 9696082
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dysfunction of Holter Mini Elliptical valves caused by minor head trauma.
    Pedersen PH; Waaler PE; Wester K
    Dev Med Child Neurol; 1992 Jan; 34(1):66-8. PubMed ID: 1544517
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Management of Hydrocephalus in Children: Anatomic Imaging Appearances of CSF Shunts and Their Complications.
    Khalatbari H; Parisi MT
    AJR Am J Roentgenol; 2021 Jan; 216(1):187-199. PubMed ID: 33112667
    [No Abstract]   [Full Text] [Related]  

  • 11. Complications of cerebrospinal fluid shunt antisiphon devices.
    da Silva MC; Drake JM
    Pediatr Neurosurg; 1991-1992; 17(6):304-9. PubMed ID: 1840818
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus. Hakim-Medos Investigator Group.
    Pollack IF; Albright AL; Adelson PD
    Neurosurgery; 1999 Dec; 45(6):1399-408; discussion 1408-11. PubMed ID: 10598708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The necessity of shunt series.
    Vassilyadi M; Tataryn ZL; Alkherayf F; Udjus K; Ventureyra EC
    J Neurosurg Pediatr; 2010 Nov; 6(5):468-73. PubMed ID: 21039171
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Laparoscopic removal of a detached peritoneal shunt catheter with revision of ventriculo-peritoneal shunt.
    Davison MJ; van Dalen RM; MacFarlane MR
    Aust N Z J Surg; 1992 Aug; 62(8):650-1. PubMed ID: 1386509
    [No Abstract]   [Full Text] [Related]  

  • 15. Percutaneous endoscopic recanalization of the catheter: a new technique of proximal shunt revision.
    Pattisapu JV; Trumble ER; Taylor KR; Howard PD; Kovach TM
    Neurosurgery; 1999 Dec; 45(6):1361-6; discussion 1366-7. PubMed ID: 10598704
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new ventricular catheter for the prevention and treatment of proximal obstruction in cerebrospinal fluid shunts.
    Ventureyra EC; Higgins MJ
    Neurosurgery; 1994 May; 34(5):924-6; discussion 926. PubMed ID: 8052397
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Explanted shunt valves: factors contributing to their failure.
    Brydon HL; Bayston R; Hayward RD; Harkness WF
    Eur J Pediatr Surg; 1994 Dec; 4 Suppl 1():37-8. PubMed ID: 7766553
    [No Abstract]   [Full Text] [Related]  

  • 18. Evaluation of hydrocephalus shunts in the emergency room.
    Dauser RC
    Emerg Med Clin North Am; 1987 Nov; 5(4):709-17. PubMed ID: 3665826
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A search for determinants of cerebrospinal fluid shunt survival: retrospective analysis of a 14-year institutional experience.
    Piatt JH; Carlson CV
    Pediatr Neurosurg; 1993; 19(5):233-41; discussion 242. PubMed ID: 8398847
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The value of baseline CT head scans in the assessment of shunt complications in hydrocephalus.
    Cantrell P; Fraser F; Pilling D; Carty H
    Pediatr Radiol; 1993; 23(6):485-6. PubMed ID: 8255661
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.