These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 7572649)

  • 1. Nonlimited exercise test combined with high-dose dipyridamole for thallium-201 myocardial single-photon emission computed tomography in coronary artery disease.
    Daou D; Le Guludec D; Faraggi M; Foult JM; Lebtahi R; Cohen-Solal A; Assayag P; Steg G
    Am J Cardiol; 1995 Oct; 76(11):753-8. PubMed ID: 7572649
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correlation of diagnostic accuracy of dipyridamole thallium-201 myocardial scintigraphy and clinical findings during stress.
    Nakayama M; Tanno M; Yamada H; Ohkawa S; Mashima S
    Jpn Heart J; 1994 May; 35(3):281-94. PubMed ID: 7933544
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Underestimation of extent and severity of coronary artery disease by dipyridamole stress thallium-201 single-photon emission computed tomographic myocardial perfusion imaging in patients taking antianginal drugs.
    Sharir T; Rabinowitz B; Livschitz S; Moalem I; Baron J; Kaplinsky E; Chouraqui P
    J Am Coll Cardiol; 1998 Jun; 31(7):1540-6. PubMed ID: 9626832
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Exercise supplementation to dipyridamole prevents hypotension, improves electrocardiogram sensitivity, and increases heart-to-liver activity ratio on Tc-99m sestamibi imaging.
    Vitola JV; Brambatti JC; Caligaris F; Lesse CR; Nogueira PR; Joaquim AI; Loyo M; Salis FV; Paiva EV; Chalela WA; Meneghetti JC
    J Nucl Cardiol; 2001; 8(6):652-9. PubMed ID: 11725261
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemodynamic indices of myocardial dysfunction correlate with dipyridamole thallium-201 SPECT.
    Chin BB; Moshin J; Bouchard M; Berlin JA; Araujo LI; Alavi A
    J Nucl Med; 1996 May; 37(5):723-9. PubMed ID: 8965134
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Altered myocardial perfusion in patients with angina pectoris or silent ischemia during exercise as assessed by quantitative thallium-201 single-photon emission computed tomography.
    Mahmarian JJ; Pratt CM; Cocanougher MK; Verani MS
    Circulation; 1990 Oct; 82(4):1305-15. PubMed ID: 2401064
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dipyridamole and exercise SPET provide different estimates of myocardial ischaemic areas: role of the severity of coronary stenoses and of the increase in heart rate during exercise.
    David N; Marie PY; Angioi M; Rodriguez RM; Hassan N; Olivier P; Grentzinger A; Karcher G; Claudon O; Juillière Y; Danchin N; Bertrand A
    Eur J Nucl Med; 2000 Jul; 27(7):788-99. PubMed ID: 10952490
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Thallium-201 scintigraphy after dipyridamole infusion in patients with ischemic heart disease--comparison with maximal exercise].
    Toyama T; Nishimura T; Uehara T; Shimonagata T; Hayashida K; Hamada S; Hirose Y; Itoh A; Nonogi H; Haze K
    Kaku Igaku; 1992 Feb; 29(2):193-201. PubMed ID: 1564789
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thallium myocardial perfusion tomography using intravenous dipyridamole combined with maximal dynamic exercise.
    Pennell DJ; Mavrogeni S; Anagnostopoulos C; Ell PJ; Underwood SR
    Nucl Med Commun; 1993 Nov; 14(11):939-45. PubMed ID: 8290165
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Quantitative thallium myocardial tomoscintigraphy. Value of intravenous infusion of dipyridamole after negative submaximal exercise test].
    Levy M; Pornin M; Languillat N; Charles JP; Angelard T; Sarkhis A; Bayet G; Guize L; Paillard M; Ourbak P
    Arch Mal Coeur Vaiss; 1992 Feb; 85(2):187-91. PubMed ID: 1562221
    [TBL] [Abstract][Full Text] [Related]  

  • 11. How well does radionuclide dipyridamole stress testing detect three-vessel coronary artery disease and ischemia in the region supplied by the most stenotic vessel?
    Zaacks SM; Ali A; Parrillo JE; Barron JT
    Clin Nucl Med; 1999 Jan; 24(1):35-41. PubMed ID: 9890491
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Usefulness of thallium-201 myocardial SPECT using dipyridamole infusion combined with low level exercise for the detection of the ischemic heart disease--comparison with SPECT images by maximum physical exercise in the same patients].
    Takao Y; Murata H; Katoh K; Onoguchi M; Ohtake E; Cho K
    Kaku Igaku; 1991 Apr; 28(4):361-70. PubMed ID: 1880970
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Dipyridamole-echocardiography and thallium exercise myocardial scintigraphy in the diagnosis of obstructive coronary or microvascular disease in hypertensive patients with left ventricular hypertrophy and angina].
    Astarita C; Nicolai E; Liguori E; Gambardella S; Rumolo S; Maresca FS
    G Ital Cardiol; 1998 Sep; 28(9):996-1004. PubMed ID: 9788038
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic accuracy of single photon emission computed tomography with thallium-201 for the identification of diseased coronary arteries. Comparison between dipyridamole infusion and exercise stress test.
    Dondi M; Monetti N; Levorato M; Corbelli C; Zagni P; Tartagni F; Maiello L; Fallani F; Ortolani P
    J Nucl Med Allied Sci; 1990; 34(1):19-23. PubMed ID: 2384820
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dobutamine stress echocardiography compared with exercise thallium-201 single-photon emission computed tomography in detecting coronary artery disease-effect of exercise level on accuracy.
    Ho YL; Wu CC; Huang PJ; Tseng WK; Lin LC; Chieng PU; Chen MF; Lee YT
    Cardiology; 1997; 88(4):379-85. PubMed ID: 9197434
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dipyridamole thallium testing: noncardiac side effects, cardiac effects, electrocardiographic changes and hemodynamic changes after dipyridamole infusion with and without exercise.
    Laarman GJ; Niemeyer MG; van der Wall EE; Verzijlbergen FJ; Go TL; Bruschke AV; Ascoop CA
    Int J Cardiol; 1988 Aug; 20(2):231-8. PubMed ID: 3209253
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ratio of lung to heart thallium-201 uptake on exercise and dipyridamole stress imaging in coronary artery disease--implication of SPECT.
    Takeishi Y; Chiba J; Abe S; Tomoike H
    Jpn Circ J; 1993 May; 57(5):379-87. PubMed ID: 8510308
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diagnosis of coronary artery disease using dipyridamole thallium-201 imaging.
    Chao CL; Lee YT; Chieng PU; Ho FM; Shiau YC; Shen SJ; Su CT; Huang PJ
    J Formos Med Assoc; 1994; 93(11-12):906-10. PubMed ID: 7633192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparing a high-dose dipyridamole SPECT imaging protocol with dobutamine and exercise stress testing protocols.
    Fleming RM; Rose CH; Feldmann KM
    Angiology; 1995 Jul; 46(7):547-56. PubMed ID: 7618757
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of thallium-201 single-photon emission computed tomographic scintigraphy with intravenous dipyridamole and arm exercise.
    Grover-McKay M; Milne N; Atwood JE; Lyons KP
    Am Heart J; 1994 Jun; 127(6):1516-20. PubMed ID: 8197977
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.