303 related articles for article (PubMed ID: 7573917)
1. Detection of cerebral venous desaturation by continuous jugular bulb oximetry following acute neurotrauma.
Lewis SB; Myburgh JA; Reilly PL
Anaesth Intensive Care; 1995 Jun; 23(3):307-14. PubMed ID: 7573917
[TBL] [Abstract][Full Text] [Related]
2. Continuous monitoring of jugular venous oxygen saturation in head-injured patients.
Sheinberg M; Kanter MJ; Robertson CS; Contant CF; Narayan RK; Grossman RG
J Neurosurg; 1992 Feb; 76(2):212-7. PubMed ID: 1472169
[TBL] [Abstract][Full Text] [Related]
3. Cerebral oxygenation monitoring by near-infrared spectroscopy is not clinically useful in patients with severe closed-head injury: a comparison with jugular venous bulb oximetry.
Lewis SB; Myburgh JA; Thornton EL; Reilly PL
Crit Care Med; 1996 Aug; 24(8):1334-8. PubMed ID: 8706488
[TBL] [Abstract][Full Text] [Related]
4. [Continuous fiberoptic monitoring of oxygen saturation in cerebral veins in severe craniocerebral trauma--experiences and results].
Murr R; Schürer L; Polasek J
Anasthesiol Intensivmed Notfallmed Schmerzther; 1996 Feb; 31(1):29-36. PubMed ID: 8868530
[TBL] [Abstract][Full Text] [Related]
5. Jugular venous desaturation and outcome after head injury.
Gopinath SP; Robertson CS; Contant CF; Hayes C; Feldman Z; Narayan RK; Grossman RG
J Neurol Neurosurg Psychiatry; 1994 Jun; 57(6):717-23. PubMed ID: 8006653
[TBL] [Abstract][Full Text] [Related]
6. Jugular bulb cannulation: description of a cannulation technique and validation of a new continuous monitor.
Andrews PJ; Dearden NM; Miller JD
Br J Anaesth; 1991 Nov; 67(5):553-8. PubMed ID: 1751268
[TBL] [Abstract][Full Text] [Related]
7. [Regional transcranial oximetry with near infrared spectroscopy (NIRS) in comparison with measuring oxygen saturation in the jugular bulb in infants and children for monitoring cerebral oxygenation].
Abdul-Khaliq H; Troitzsch D; Berger F; Lange PE
Biomed Tech (Berl); 2000 Nov; 45(11):328-32. PubMed ID: 11155535
[TBL] [Abstract][Full Text] [Related]
8. Jugular bulb oximetry: review on a cerebral monitoring technique.
De Deyne C; Van Aken J; Decruyenaere J; Struys M; Colardyn F
Acta Anaesthesiol Belg; 1998; 49(1):21-31. PubMed ID: 9627734
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of a 7.5 French pulmonary catheter for continuous monitoring of cerebral venous oxygen saturation.
Olsen KS; Madsen PL; Børme T; Schmidt JF
J Neurosurg Anesthesiol; 1994 Oct; 6(4):233-8. PubMed ID: 8000197
[TBL] [Abstract][Full Text] [Related]
10. Monitoring of cerebral oxygenation in patients with severe head injuries: brain tissue PO2 versus jugular vein oxygen saturation.
Kiening KL; Unterberg AW; Bardt TF; Schneider GH; Lanksch WR
J Neurosurg; 1996 Nov; 85(5):751-7. PubMed ID: 8893710
[TBL] [Abstract][Full Text] [Related]
11. Is jugular bulb oximetry monitoring associated with outcome in out of hospital cardiac arrest patients?
Richter J; Sklienka P; Setra AE; Zahorec R; Das S; Chatterjee N
J Clin Monit Comput; 2021 Aug; 35(4):741-748. PubMed ID: 32435933
[TBL] [Abstract][Full Text] [Related]
12. Continuous monitoring of jugular bulb oxygen saturation in comatose patients--therapeutic implications.
Schneider GH; von Helden A; Lanksch WR; Unterberg A
Acta Neurochir (Wien); 1995; 134(1-2):71-5. PubMed ID: 7668132
[TBL] [Abstract][Full Text] [Related]
13. A prospective, randomized comparison of cerebral venous oxygen saturation during normothermic and hypothermic cardiopulmonary bypass.
Cook DJ; Oliver WC; Orszulak TA; Daly RC
J Thorac Cardiovasc Surg; 1994 Apr; 107(4):1020-8; discussion 1028-9. PubMed ID: 8159022
[TBL] [Abstract][Full Text] [Related]
14. Accuracy of continuous jugular bulb oximetry in the intensive care unit.
Coplin WM; O'Keefe GE; Grady MS; Grant GA; March KS; Winn HR; Lam AM
Neurosurgery; 1998 Mar; 42(3):533-9; discussion 539-40. PubMed ID: 9526988
[TBL] [Abstract][Full Text] [Related]
15. Clinical experience with intraoperative jugular venous oximetry during pediatric intracranial neurosurgery.
Sharma D; Siriussawakul A; Dooney N; Hecker JG; Vavilala MS
Paediatr Anaesth; 2013 Jan; 23(1):84-90. PubMed ID: 23004361
[TBL] [Abstract][Full Text] [Related]
16. Accuracy of continuous jugular bulb venous oximetry during intracranial surgery.
Gunn HC; Matta BF; Lam AM; Mayberg TS
J Neurosurg Anesthesiol; 1995 Jul; 7(3):174-7. PubMed ID: 7549368
[TBL] [Abstract][Full Text] [Related]
17. Brain Hypoxia Secondary to Diffusion Limitation in Hypoxic Ischemic Brain Injury Postcardiac Arrest.
Sekhon MS; Ainslie PN; Menon DK; Thiara SS; Cardim D; Gupta AK; Hoiland RL; Gooderham P; Griesdale DE
Crit Care Med; 2020 Mar; 48(3):378-384. PubMed ID: 31789834
[TBL] [Abstract][Full Text] [Related]
18. Jugular bulb desaturation during off-pump coronary artery bypass surgery.
Miura N; Yoshitani K; Kawaguchi M; Shinzawa M; Irie T; Uchida O; Ohnishi Y; Mackensen GB
J Anesth; 2009; 23(4):477-82. PubMed ID: 19921353
[TBL] [Abstract][Full Text] [Related]
19. Jugular venous bulb oxyhemoglobin saturation during cardiac surgery: accuracy and reliability using a continuous monitor.
Trubiano P; Heyer EJ; Adams DC; McMahon DJ; Christiansen I; Rose EA; Delphin E
Anesth Analg; 1996 May; 82(5):964-8. PubMed ID: 8610907
[TBL] [Abstract][Full Text] [Related]
20. Correlation of jugular venous oxygen saturation to spontaneous fluctuations of cerebral perfusion pressure in patients with severe head injury.
Murr R; Schürer L
Neurol Res; 1995 Oct; 17(5):329-33. PubMed ID: 8584122
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]