These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 757591)

  • 1. Reversed-phase systems for the analysis of catecholamines and related compounds by high-performance liquid chromatography.
    Crombeen JP; Kraak JC; Poppe H
    J Chromatogr; 1978 Dec; 167():219-30. PubMed ID: 757591
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of silica-based hyper-crosslinked sulfonate-modified reversed stationary phases for separating highly hydrophilic basic compounds.
    Luo H; Ma L; Paek C; Carr PW
    J Chromatogr A; 2008 Aug; 1202(1):8-18. PubMed ID: 18617181
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anion-exchange chromatography on short reversed-phase columns modified with amphoteric (N-dodecyl-N,N-dimethylammonio)alcanoates.
    Nesterenko EP; Nesterenko PN; Paull B
    J Chromatogr A; 2008 Jan; 1178(1-2):60-70. PubMed ID: 18054786
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance of different C18 columns in reversed-phase liquid chromatography with hydro-organic and micellar-organic mobile phases.
    Ruiz-Angel MJ; Pous-Torres S; Carda-Broch S; García-Alvarez-Coque MC
    J Chromatogr A; 2014 May; 1344():76-82. PubMed ID: 24767835
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Separation of peptides dissolved in a sodium dodecyl sulfate solution by reversed-phase liquid chromatography: removal of sodium dodecyl sulfate from peptides using an ion-exchange precolumn.
    Kawasaki H; Suzuki K
    Anal Biochem; 1990 May; 186(2):264-8. PubMed ID: 2363498
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Synthesis and evaluation of porous polymethylsilsesquioxane microspheres as low silanol activity chromatographic stationary phase for basic compound separation.
    Huo Z; Wan Q; Chen L
    J Chromatogr A; 2018 Jun; 1553():90-100. PubMed ID: 29673768
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Separation of catecholamines and their metabolites by adsorption, ion-pair and soap chromatography.
    Knox JH; Jurand J
    J Chromatogr; 1976 Sep; 125(1):89-101. PubMed ID: 977684
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reversed-phase high-performance liquid chromatography behavior of chaotropic counteranions.
    Kazakevich YV; LoBrutto R; Vivilecchia R
    J Chromatogr A; 2005 Jan; 1064(1):9-18. PubMed ID: 15729815
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reverse-phase chromatography of polar biological substances: separation of catechol compounds by high-performance liquid chromatography.
    Molnár I; Horváth C
    Clin Chem; 1976 Sep; 22(9):1497-502. PubMed ID: 8221
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Separation of basic drug substances by reversed-phase high-performance liquid chromatography on dynamically modified silica and on bonded-phase materials.
    Hansen SH; Helboe P; Thomsen M
    J Chromatogr; 1987 Nov; 409():71-80. PubMed ID: 2826515
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of fused-core and monolithic versus porous silica-based C18 columns and porous graphitic carbon for ion-pairing liquid chromatography analysis of catecholamines and related compounds.
    Chirita RI; Finaru AL; Elfakir C
    J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Mar; 879(9-10):633-40. PubMed ID: 21345749
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of catecholamines in urine (and plasma) by liquid chromatography after on-line sample pretreatment on small alumina or dihydroxyborylsilica columns.
    de Jong J; Point AJ; Tjaden UR; Beeksma S; Kraak JC
    J Chromatogr; 1987 Mar; 414(2):285-300. PubMed ID: 3033003
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cation-exchange liquid chromatography of choline and acetylcholine on free shielded silanols of silica-based reversed-phase stationary phases.
    Salamoun J; Nguyen PT; Remien J
    J Chromatogr; 1992 Apr; 596(1):43-9. PubMed ID: 1325987
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-performance liquid chromatographic analysis of basic drugs on silica columns using non-aqueous ionic eluents. I. Factors influencing retention, peak shape and detector response.
    Flanagan RJ; Jane I
    J Chromatogr; 1985 Apr; 323(2):173-89. PubMed ID: 2987280
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Separation of proteins by consecutive sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis and reversed phase high performance liquid chromatography.
    Kaplan B; Pras M
    Biomed Chromatogr; 1991 Mar; 5(2):86-9. PubMed ID: 1868264
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improvement of peak shape and separation performance of beta-blockers in conventional reversed-phase columns using solvent modifiers.
    Ruiz-Angel MJ; Torres-Lapasió JR; Carda-Broch S; García-Alvarez-Coque MC
    J Chromatogr Sci; 2003 Aug; 41(7):350-8. PubMed ID: 12908951
    [TBL] [Abstract][Full Text] [Related]  

  • 17. HPLC of basic drugs on microparticulate strong cation-exchange materials - a review.
    Flanagan RJ; Harvey EJ; Spencer EP
    Forensic Sci Int; 2001 Sep; 121(1-2):97-102. PubMed ID: 11516893
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retention pattern profiling of fungal metabolites on mixed-mode reversed-phase/weak anion exchange stationary phases in comparison to reversed-phase and weak anion exchange separation materials by liquid chromatography-electrospray ionisation-tandem mass spectrometry.
    Apfelthaler E; Bicker W; Lämmerhofer M; Sulyok M; Krska R; Lindner W; Schuhmacher R
    J Chromatogr A; 2008 May; 1191(1-2):171-81. PubMed ID: 18199445
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hexafluoroisopropanol-modified cetyltrimethylammonium bromide/sodium dodecyl sulfate vesicles as a pseudostationary phase in electrokinetic chromatography.
    Tian Y; Li Y; Mei J; Deng B; Xiao Y
    J Chromatogr A; 2015 Jul; 1404():131-40. PubMed ID: 26044380
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Separation properties of novel and commercial polar stationary phases in hydrophilic interaction and reversed-phase liquid chromatography mode.
    Wu J; Bicker W; Lindner W
    J Sep Sci; 2008 May; 31(9):1492-503. PubMed ID: 18461572
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.