BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 7576675)

  • 1. Saline soaked pledgets prevent carbon dioxide laser-induced endotracheal tube cuff ignition.
    Sosis MB
    J Clin Anesth; 1995 Aug; 7(5):395-7. PubMed ID: 7576675
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Saline-filled cuffs help prevent laser-induced polyvinylchloride endotracheal tube fires.
    Sosis MB; Dillon FX
    Anesth Analg; 1991 Feb; 72(2):187-9. PubMed ID: 1985502
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prevention of CO2 laser-induced endotracheal tube fires with the laser-guard protective coating.
    Sosis MB; Dillon F
    J Clin Anesth; 1992; 4(1):25-7. PubMed ID: 1540365
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of a technique of nitrogen insufflation to decrease plastic endotracheal tube cuff flammability during carbon dioxide laser surgery.
    Sosis MB
    J Clin Anesth; 1993; 5(6):468-70. PubMed ID: 8123272
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endotracheal tube safety during laser surgery.
    Fontenot R; Bailey BJ; Stiernberg CM; Jenicek JA
    Laryngoscope; 1987 Aug; 97(8 Pt 1):919-21. PubMed ID: 3613790
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of blood on laser-resistant endotracheal tube combustion.
    Sosis MB; Pritikin JB; Caldarelli DD
    Laryngoscope; 1994 Jul; 104(7):829-31. PubMed ID: 8022244
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Advantage of rubber over plastic endotracheal tubes for rapid extubation in a laser fire.
    Sosis MB; Braverman B
    J Clin Laser Med Surg; 1996 Apr; 14(2):93-5. PubMed ID: 9484083
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Saline soaked pledgets prevent CO2 laser induced tracheal tube cuff ignition.
    Sosis M
    Can J Anaesth; 1990 May; 37(4 Pt 2):S72. PubMed ID: 2361311
    [No Abstract]   [Full Text] [Related]  

  • 9. A comparison of CO2 laser ignition of the Xomed, plastic, and rubber endotracheal tubes.
    Sosis MB; Dillon FX
    Anesth Analg; 1993 Feb; 76(2):391-3. PubMed ID: 8424521
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Injuries to the bronchi and lungs caused by laser-ignited endotracheal tube fires.
    Duncavage JA; Ossoff RH; Rouman WC; Toohill RJ; Almagro UA; Carl GA; Aronson S
    Otolaryngol Head Neck Surg; 1984 Dec; 92(6):639-43. PubMed ID: 6440081
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of foil coverings for protecting plastic endotracheal tubes from the potassium-titanyl-phosphate laser.
    Sosis MB; Braverman B
    Anesth Analg; 1993 Sep; 77(3):589-91. PubMed ID: 8368560
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Laryngeal surgery using a CO2 laser: is a polyvinylchloride endotracheal tube safe?
    Li S; Chen L; Tan F
    Am J Otolaryngol; 2012; 33(6):714-7. PubMed ID: 22884483
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surgical fires in laser laryngeal surgery: are we safe enough?
    Roy S; Smith LP
    Otolaryngol Head Neck Surg; 2015 Jan; 152(1):67-72. PubMed ID: 25344591
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Positive end-expiratory pressure lowers the risk of laser-induced polyvinylchloride tracheal-tube fires.
    Pashayan AG; SanGiovanni C; Davis LE
    Anesthesiology; 1993 Jul; 79(1):83-7. PubMed ID: 8342831
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hazards of a new, clear, unmarked polyvinylchloride tracheal tube designed for use with the Nd-YAG laser.
    Sosis M; Dillon F
    J Clin Anesth; 1991; 3(5):358-60. PubMed ID: 1931058
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incendiary characteristics of a new laser-resistant endotracheal tube.
    Hayes DM; Gaba DM; Goode RL
    Otolaryngol Head Neck Surg; 1986 Jul; 95(1):37-40. PubMed ID: 3106892
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metal anesthesia circuit components stop the progression of laser fires.
    Sosis MB; Braverman B
    J Clin Anesth; 1994; 6(1):52-4. PubMed ID: 8142101
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Which is the safest endotracheal tube for use with the CO2 laser? A comparative study.
    Sosis MB
    J Clin Anesth; 1992; 4(3):217-9. PubMed ID: 1610578
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fires of endotracheal tubes of three different materials during carbon dioxide laser surgery.
    Lai HC; Juang SE; Liu TJ; Ho WM
    Acta Anaesthesiol Sin; 2002 Mar; 40(1):47-51. PubMed ID: 11989049
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A management option for leaking endotracheal tube cuffs: use of lidocaine jelly.
    Schubert A; Von Kaenel W; Ilyes L
    J Clin Anesth; 1991; 3(1):26-31. PubMed ID: 2007038
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.