8. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Bachiller PR; McDonough JM; Feldman JM Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850 [TBL] [Abstract][Full Text] [Related]
9. Lung aeration during ventilation after recruitment guided by tidal elimination of carbon dioxide and dynamic compliance was better than after end-tidal carbon dioxide targeted ventilation: a computed tomography study in surfactant-depleted piglets. Hanson A; Göthberg S; Nilsson K; Hedenstierna G Pediatr Crit Care Med; 2011 Nov; 12(6):e362-8. PubMed ID: 21263364 [TBL] [Abstract][Full Text] [Related]
10. In vitro compound A formation in a computer-controlled closed-circuit anesthetic apparatus. Comparison with a classical valve circuit. Versichelen LF; Rolly G; Bouche MP; Van Bocxlaer JF; Struys MM; Van Der Herten C; De Leenheer AP; Mortier EP Anesthesiology; 2000 Oct; 93(4):1064-8. PubMed ID: 11020762 [TBL] [Abstract][Full Text] [Related]
11. Leak compensation in positive pressure ventilators: a lung model study. Mehta S; McCool FD; Hill NS Eur Respir J; 2001 Feb; 17(2):259-67. PubMed ID: 11334129 [TBL] [Abstract][Full Text] [Related]
12. Carbon dioxide distribution in Mapleson A and D systems: an experimental study. Andersen PK; Olsen JE; Jensen A; Stokke DB Acta Anaesthesiol Scand; 1989 Aug; 33(6):439-43. PubMed ID: 2508406 [TBL] [Abstract][Full Text] [Related]
13. Calculation of end-tidal carbon dioxide fractions in the Bain system. Jonsson LO; Zetterström H Acta Anaesthesiol Scand; 1989 Jan; 33(1):71-4. PubMed ID: 2492710 [TBL] [Abstract][Full Text] [Related]
14. A closed xenon anesthesia delivery system. Dingley J; Findlay GP; Foëx BA; Mecklenburgh J; Esmail M; Little RA Anesthesiology; 2001 Jan; 94(1):173-6. PubMed ID: 11135742 [No Abstract] [Full Text] [Related]
15. FLOW-i ventilator performance in the presence of a circle system leak. Lucangelo U; Ajčević M; Accardo A; Borelli M; Peratoner A; Comuzzi L; Zin WA J Clin Monit Comput; 2017 Apr; 31(2):273-280. PubMed ID: 27062381 [TBL] [Abstract][Full Text] [Related]
16. The long Bain breathing system: an investigation into the implications of remote ventilation. Sweeting CJ; Thomas PW; Sanders DJ Anaesthesia; 2002 Dec; 57(12):1183-6. PubMed ID: 12437709 [TBL] [Abstract][Full Text] [Related]
17. [Accessory anesthetic circuit and principal circuit]. Bourgain JL; Beydon L; Feiss P Ann Fr Anesth Reanim; 1998; 17(9):1182. PubMed ID: 9835994 [No Abstract] [Full Text] [Related]
18. [Measurements of ventilatory parameters during closed circuit anesthesia--comparisons with semiclosed circuit, high-flow anesthesia]. Morita S; Saito H; Hayashi T; Goto T; Niimi Y Masui; 1995 Feb; 44(2):210-5. PubMed ID: 7739092 [TBL] [Abstract][Full Text] [Related]
19. The use of the Copper Kettle vaporizer in closed system carbon dioxide absorption anaesthesia. Morris LE Anaesth Intensive Care; 1994 Aug; 22(4):383-6. PubMed ID: 7978200 [No Abstract] [Full Text] [Related]
20. Electronic measurement and control of gas flow. White DC Anaesth Intensive Care; 1994 Aug; 22(4):409-14. PubMed ID: 7978205 [No Abstract] [Full Text] [Related] [Next] [New Search]