These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
121 related articles for article (PubMed ID: 7577302)
1. A subtle cause of circle system failure. Findlay GP; Spittal MJ Br J Anaesth; 1995 Nov; 75(5):667-8. PubMed ID: 7577302 [No Abstract] [Full Text] [Related]
2. Three cases of valve incompetence in a circle system. Rosewarne F; Wells D Anaesth Intensive Care; 1988 Aug; 16(3):376-7. PubMed ID: 3189750 [No Abstract] [Full Text] [Related]
3. More on equipment failure. Doyle DJ Can J Anaesth; 1999 Aug; 46(8):810. PubMed ID: 10451150 [No Abstract] [Full Text] [Related]
4. [Faulty functioning of the expiration valve in the Dräger circle system]. Hecker E Anaesthesist; 1989 Mar; 38(3):152. PubMed ID: 2719230 [No Abstract] [Full Text] [Related]
6. A hidden leak in the circle system. Yassin K; Gibbons JJ Anesth Analg; 1991 Aug; 73(2):236. PubMed ID: 1854044 [No Abstract] [Full Text] [Related]
7. One-way valve malfunction in a circle system. Thomson AR; Gordon NH Anaesthesia; 1995 Oct; 50(10):920-1. PubMed ID: 7485905 [No Abstract] [Full Text] [Related]
8. Another cause for a leak in a disposable breathing circuit. Sosis MB; Payne MN Anesthesiology; 1989 Nov; 71(5):806. PubMed ID: 2817484 [No Abstract] [Full Text] [Related]
9. Design flaw in an anesthesia machine. Pomykala Z; Schechter H Anesthesiology; 1992 Aug; 77(2):399-400. PubMed ID: 1642368 [No Abstract] [Full Text] [Related]
10. Test for a leak in the anesthesia circle. Ghani GA Anesth Analg; 1983 Sep; 62(9):855-6. PubMed ID: 6576649 [No Abstract] [Full Text] [Related]
11. Checking the Lack breathing system. Normandale JP; Found P Anaesthesia; 1994 Aug; 49(8):735-6. PubMed ID: 7943718 [No Abstract] [Full Text] [Related]
12. A potentially serious anesthesia system malfunction. Springman SR; Malischke P Anesthesiology; 1986 Nov; 65(5):563-4. PubMed ID: 3777498 [No Abstract] [Full Text] [Related]
13. Failure of double-lumen tube cuff deflation on the cuff leak test. Nakazawa K; Ohtaha M; Makita K J Cardiothorac Vasc Anesth; 2010 Dec; 24(6):1025. PubMed ID: 20036153 [No Abstract] [Full Text] [Related]
14. Ventilator alarm nonfunction associated with a scavenging system for waste gases. Heard SO; Munson ES Anesth Analg; 1983 Feb; 62(2):230-2. PubMed ID: 6829925 [No Abstract] [Full Text] [Related]
16. [Faulty functioning of the expiration valve of the Dräger circle system]. Link J Anaesthesist; 1988 Oct; 37(10):648-9. PubMed ID: 3213940 [TBL] [Abstract][Full Text] [Related]
17. [French survey on current equipment and progress to be made in matters of safety]. Noviant Y; Bourgain JL; Duranteau J; Deriaz H Cah Anesthesiol; 1986; 34(4):297-9. PubMed ID: 3463376 [No Abstract] [Full Text] [Related]
18. [Safety problems related to the gas distribution system]. Erny P; Dabadie P Cah Anesthesiol; 1986; 34(4):291-4. PubMed ID: 3756566 [No Abstract] [Full Text] [Related]
19. Persistent narrowing of an armoured tube. Martens P Anaesthesia; 1992 Aug; 47(8):716-7. PubMed ID: 1519734 [No Abstract] [Full Text] [Related]