  • 21. [Doppler echocardiographic determination of the effective orifice area of mechanical heart valve prostheses in a flow model].
    Fehske W; Köhler J; Rabahieh R; Braun P; Hostert A; Lüderitz B
    Z Kardiol; 1991 Jul; 80(7):441-8. PubMed ID: 1926989
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Hemodynamic and hemolytic features of the St. Jude Medical valve prostheses.
    Sezai Y; Umeda S; Okazaki T; Okamoto I; Rikukawa H; Shiono M
    J Cardiovasc Surg (Torino); 1984; 25(1):16-24. PubMed ID: 6707068
    [TBL] [Abstract][Full Text] [Related]  

  • 23. In vitro assessment of prosthesis type and pressure recovery characteristics: Doppler echocardiography overestimation of bileaflet mechanical and bioprosthetic aortic valve gradients.
    Bach DS; Schmitz C; Dohmen G; Aaronson KD; Steinseifer U; Kleine P
    J Thorac Cardiovasc Surg; 2012 Aug; 144(2):453-8. PubMed ID: 22264413
    [TBL] [Abstract][Full Text] [Related]  

  • 24. In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Björk-Shiley Monostrut, Omni-Carbon, and Duromedics.
    Yoganathan AP; Sung HW; Woo YR; Jones M
    J Thorac Cardiovasc Surg; 1988 May; 95(5):929-39. PubMed ID: 3361941
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Doppler sonographic evaluation of the Duromedics-Edwards bileaflet valve at five-year follow up.
    Globits S; Rödler S; Moritz A; Schreiner W; Pacher R; Glogar D; Wolner E
    J Heart Valve Dis; 1993 Nov; 2(6):665-70. PubMed ID: 7719508
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of mechanical aortic valve orientation on coronary artery flow: comparison of tilting disc versus bileaflet prostheses in pigs.
    Kleine P; Scherer M; Abdel-Rahman U; Klesius AA; Ackermann H; Moritz A
    J Thorac Cardiovasc Surg; 2002 Nov; 124(5):925-32. PubMed ID: 12407375
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Rest and exercise evaluation of St. Jude Medical and Medtronic Hall prostheses. Influence of primary lesion, valvular type, valvular size, and left ventricular function.
    Tatineni S; Barner HB; Pearson AC; Halbe D; Woodruff R; Labovitz AJ
    Circulation; 1989 Sep; 80(3 Pt 1):I16-23. PubMed ID: 2766522
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Carbomedics and St. Jude Medical bileaflet valves: an in vitro and in vivo comparison.
    Johnston RT; Weerasena NA; Butterfield M; Fisher J; Spyt TJ
    Eur J Cardiothorac Surg; 1992; 6(5):267-71. PubMed ID: 1610596
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation.
    Chafizadeh ER; Zoghbi WA
    Circulation; 1991 Jan; 83(1):213-23. PubMed ID: 1984881
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Hemodynamic performances of small diameter carbomedics and St. Jude valves.
    De Paulis R; Sommariva L; De Matteis GM; Polisca P; Tomai F; Bassano C; Penta de Peppo A; Chiariello L
    J Heart Valve Dis; 1996 Nov; 5 Suppl 3():S339-43. PubMed ID: 8953465
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Rest and exercise hemodynamics of 20 to 23 mm allograft, Medtronic Intact (porcine), and St. Jude Medical valves in the aortic position.
    Jaffe WM; Coverdale HA; Roche AH; Whitlock RM; Neutze JM; Barratt-Boyes BG
    J Thorac Cardiovasc Surg; 1990 Aug; 100(2):167-74. PubMed ID: 2385114
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Improved Doppler assessment of the Bjork-Shiley mitral prosthesis using the continuity equation.
    Mohan JC; Agrawal R; Arora R; Khalilullah M
    Int J Cardiol; 1994 Mar; 43(3):321-6. PubMed ID: 8181890
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Coronary perfusion: impact of flow dynamics and geometric design of 2 different aortic prostheses of similar size.
    Mannacio V; Di Tommaso L; De Amicis V; Stassano P; Vosa C
    J Thorac Cardiovasc Surg; 2012 May; 143(5):1030-5. PubMed ID: 21752400
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Non-invasive determination of pressure gradients of heart valve prostheses using Doppler ultrasound].
    Hoffmann A; Amann FW; Grädel E; Burckhardt D
    Schweiz Med Wochenschr; 1982 Nov; 112(45):1600-3. PubMed ID: 7156956
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Doppler echocardiographic evaluation of St. Jude Medical valves in the tricuspid position.
    Aoyagi S; Nishi Y; Kawara T; Oryoji A; Kosuga K; Ohishi K
    J Heart Valve Dis; 1993 May; 2(3):279-86. PubMed ID: 8269120
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hemodynamics of St. Jude Medical prostheses in the small aortic root: in vivo studies using dobutamine Doppler echocardiography.
    Kadir I; Izzat MB; Birdi I; Wilde P; Reeves B; Bryan AJ; Angelini GD
    J Heart Valve Dis; 1997 Mar; 6(2):123-9. PubMed ID: 9130118
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Doppler echocardiographic study of three different mechanical valves in the aortic position: the use of external nominal diameter indexed to body surface area.
    Bailly P; Camilleri L; Legault B; Fleury JP; D'Agrosa EM; de Riberolles C
    J Heart Valve Dis; 1997 May; 6(3):236-48. PubMed ID: 9183721
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Contribution of Doppler echocardiography in the evaluation of normal and pathologic aortic valve prosthesis].
    Habib G; Bénichou M; Gisbert MP; Bonnet JL; Scemama J; Djiane P; Bory M; Serradigmigni A
    Arch Mal Coeur Vaiss; 1990 Jun; 83(7):937-45. PubMed ID: 2114853
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Clinical experience and Doppler echocardiographic assessment of the first one hundred ATS AP (advanced performance) prosthetic valve in the aortic position.
    Jazayeri S; Gomez MC; Tatou E; Ecarnot A; Saleh M; Bouchot O; Renaud C; Brenot R; David M
    J Heart Valve Dis; 2003 Sep; 12(5):628-34; discussion 634. PubMed ID: 14565717
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Comparative study of mechanical heart valves for implantation in mitral position].
    Heiliger R; Lambertz H; Geks J; Mittermayer C
    Herz; 1987 Dec; 12(6):405-12. PubMed ID: 3428845
    [TBL] [Abstract][Full Text] [Related]  