These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 7588895)

  • 1. Efficacy and safety of collagen implants for haemostasis of the vascular access site after coronary balloon angioplasty and coronary stent implantation. A randomized study.
    von Hoch F; Neumann FJ; Theiss W; Kastrati A; Schömig A
    Eur Heart J; 1995 May; 16(5):640-6. PubMed ID: 7588895
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.
    Sanborn TA; Gibbs HH; Brinker JA; Knopf WD; Kosinski EJ; Roubin GS
    J Am Coll Cardiol; 1993 Nov; 22(5):1273-9. PubMed ID: 8227779
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.
    Sanborn TA; Gibbs HH; Brinker JA; Knopf WD; Kosinksi EJ; Roubin GS
    J Invasive Cardiol; 1999 Sep; 11 Suppl B():6B-13B. PubMed ID: 10745611
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of vascular sealing devices (VasoSeal and Perclose) versus assisted manual compression (Femostop) in transcatheter coronary interventions requiring abciximab (ReoPro).
    Chamberlin JR; Lardi AB; McKeever LS; Wang MH; Ramadurai G; Grunenwald P; Towne WP; Grassman ED; Leya FS; Lewis BE; Stein LH
    Catheter Cardiovasc Interv; 1999 Jun; 47(2):143-7; discussion 148. PubMed ID: 10376492
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Collagen plug hemostatic closure of femoral arterial puncture sites following implantation of intracoronary stents.
    Webb JG; Carere RA; Dodek AA
    Cathet Cardiovasc Diagn; 1993 Dec; 30(4):314-6. PubMed ID: 8287459
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid hemostasis of arterial puncture sites with collagen in patients undergoing diagnostic and interventional cardiac catheterization.
    Silber S
    Clin Cardiol; 1997 Dec; 20(12):981-92. PubMed ID: 9422835
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prompt and safe femoral hemostasis with a collagen device after intracoronary implantation of Palmaz-Schatz stents.
    Bartorelli AL; Sganzerla P; Fabbiocchi F; Montorsi P; De Cesare N; Child M; Tavasci E; Passaretti B; Loaldi A
    Am Heart J; 1995 Jul; 130(1):26-32. PubMed ID: 7611119
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rationale and design of a randomised clinical trial comparing vascular closure device and manual compression to achieve haemostasis after diagnostic coronary angiography: the Instrumental Sealing of ARterial puncture site - CLOSURE device versus manual compression (ISAR-CLOSURE) trial.
    Xhepa E; Byrne RA; Schulz S; Helde S; Gewalt S; Cassese S; Linhardt M; Ibrahim T; Mehilli J; Hoppe K; Grupp K; Kufner S; Böttiger C; Hoppmann P; Burgdorf C; Fusaro M; Ott I; Schneider S; Hengstenberg C; Schunkert H; Laugwitz KL; Kastrati A;
    EuroIntervention; 2014 Jun; 10(2):198-203. PubMed ID: 24952057
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Early hemostasis after coronary therapeutic interventions by using a collagen plug].
    Kühn C; Sümpelmann D; Geiger B; Siems R; Kunze KP; Geiger M; Mathey D; Schofer J
    Z Kardiol; 1993 Aug; 82(8):515-20. PubMed ID: 8212785
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Stents for treatment of transluminal percutaneous coronary angioplasty (PTCA) complications].
    Pieniazek P; Przewłocki T; Zmudka K; Tracz W; Dudek D; Pietrzak I; Bryniarski L; Sadowski J; Kapelak B; Drwiła R
    Przegl Lek; 1998; 55(7-8):373-7. PubMed ID: 10021879
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Collagen application versus manual compression: a prospective randomized trial for arterial puncture site closure after coronary angioplasty.
    Camenzind E; Grossholz M; Urban P; Dorsaz PA; Didier D; Meier B
    J Am Coll Cardiol; 1994 Sep; 24(3):655-62. PubMed ID: 8077535
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Two hour ambulation after coronary angioplasty and stenting with 6 F guiding catheters and low dose heparin.
    Koch KT; Piek JJ; de Winter RJ; Mulder K; Schotborgh CE; Tijssen JG; Lie KI
    Heart; 1999 Jan; 81(1):53-6. PubMed ID: 10220545
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of coronary artery stents on mortality and nonfatal myocardial infarction: meta-analysis of randomized trials comparing a strategy of routine stenting with that of balloon angioplasty.
    Al Suwaidi J; Holmes DR; Salam AM; Lennon R; Berger PB
    Am Heart J; 2004 May; 147(5):815-22. PubMed ID: 15131536
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel vascular sealing device for closure of percutaneous arterial access sites.
    Silber S; Gershony G; Schön B; Schön N; Jensen T; Schramm W
    Am J Cardiol; 1999 Apr; 83(8):1248-52. PubMed ID: 10215293
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Access site complications following transfemoral coronary procedures: comparison between traditional compression and angioseal vascular closure devices for haemostasis.
    Wu PJ; Dai YT; Kao HL; Chang CH; Lou MF
    BMC Cardiovasc Disord; 2015 May; 15():34. PubMed ID: 25956814
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Systematic use of a collagen-based vascular closure device immediately after cardiac catheterization procedures in 1,317 consecutive patients.
    Eggebrecht H; Haude M; Woertgen U; Schmermund A; von Birgelen C; Naber C; Baumgart D; Kaiser C; Oldenburg O; Bartel T; Kroeger K; Erbel R
    Catheter Cardiovasc Interv; 2002 Dec; 57(4):486-95. PubMed ID: 12455083
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Latin American randomized trial of balloon angioplasty vs coronary stenting for small vessels (LASMAL): immediate and long-term results.
    Rodriguez A; Rodríguez Alemparte M; Fernández Pereira C; Sampaolesi A; da Rocha Loures Bueno R; Vigo F; Obregón A; Palacios IF;
    Am J Med; 2005 Jul; 118(7):743-51. PubMed ID: 15989908
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Predictors of groin complications after balloon and new-device coronary intervention.
    Waksman R; King SB; Douglas JS; Shen Y; Ewing H; Mueller L; Ghazzal ZM; Weintraub WS
    Am J Cardiol; 1995 May; 75(14):886-9. PubMed ID: 7732995
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stent implantation reduces restenosis in patients with suboptimal results following coronary angioplasty.
    Knight CJ; Curzen NP; Groves PH; Patel DJ; Goodall AH; Wright C; Clarke D; Oldershaw PJ; Fox KM
    Eur Heart J; 1999 Dec; 20(24):1783-90. PubMed ID: 10581136
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An open design, multicentre, randomized trial of percutaneous transluminal coronary angioplasty versus stenting, with a heparin-coated stent, of totally occluded coronary arteries: rationale, trial design and baseline patient characteristics. Total Occlusion Study of Canada (TOSCA) Investigators.
    Dzavik V; Carere RG; Teo KK; Knudtson ML; Marquis JF; Buller CE
    Can J Cardiol; 1998 Jun; 14(6):825-32. PubMed ID: 9676168
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.