These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
173 related articles for article (PubMed ID: 7594994)
1. Absorbable sutures in tendon repair. A comparison of PDS with prolene in rabbit tendon repair. O'Broin ES; Earley MJ; Smyth H; Hooper AC J Hand Surg Br; 1995 Aug; 20(4):505-8. PubMed ID: 7594994 [TBL] [Abstract][Full Text] [Related]
2. Effect of absorbable polydioxanone flexor tendon repair and restricted active mobilization in a canine model. Wada A; Kubota H; Akiyama T; Hatanaka H; Miura H; Iwamoto Y J Hand Surg Am; 2001 May; 26(3):398-406. PubMed ID: 11418899 [TBL] [Abstract][Full Text] [Related]
3. Does plastic suture deformation induce gapping after tendon repair? A biomechanical comparison of different suture materials. Jordan MC; Boelch S; Jansen H; Meffert RH; Hoelscher-Doht S J Biomech; 2016 Sep; 49(13):2607-2612. PubMed ID: 27264620 [TBL] [Abstract][Full Text] [Related]
4. [Tendon sutures with a new monofilament synthetic absorbable suture material (PDS-suture of 6-0 strength). Results of animal experiments]. Albers W; Geldmacher J; Giedl H; Beyer W Chirurg; 1982 Mar; 53(3):168-71. PubMed ID: 6802585 [TBL] [Abstract][Full Text] [Related]
5. Comparison of the mechanical properties of polyglycolide-trimethylene carbonate (Maxon) and polydioxanone sutures (PDS2) used for flexor tendon repair and active mobilization. Wada A; Kubota H; Taketa M; Miuri H; Iwamoto Y J Hand Surg Br; 2002 Aug; 27(4):329-32. PubMed ID: 12162970 [TBL] [Abstract][Full Text] [Related]
6. Nickel-titanium wire in circumferential suture of a flexor tendon repair: a comparison to polypropylene. Karjalainen T; He M; Chong AK; Lim AY; Ryhanen J J Hand Surg Am; 2010 Jul; 35(7):1160-4. PubMed ID: 20610061 [TBL] [Abstract][Full Text] [Related]
7. Comparison of polydioxanone (PDS) and polypropylene (Prolene) for Shouldice repair of primary inguinal hernias: a prospective randomised trial. Hilgert RE; Dörner A; Wittkugel O Eur J Surg; 1999 Apr; 165(4):333-8. PubMed ID: 10365834 [TBL] [Abstract][Full Text] [Related]
8. A biomechanical study of pediatric flexor profundus tendon repair. Comparing the tensile strengths of 3 suture techniques. Al-Thunayan TA; Al-Zahrani MT; Hakeem AA; Al-Zahrani FM; Al-Qattan MM Saudi Med J; 2016 Sep; 37(9):957-62. PubMed ID: 27570850 [TBL] [Abstract][Full Text] [Related]
9. Comparison between absorbable and nonabsorbable, monofilament sutures for end-to-end arterial anastomoses in growing pigs. Steen S; Andersson L; Löwenhielm P; Stridbeck H; Walther B; Holmin T Surgery; 1984 Feb; 95(2):202-8. PubMed ID: 6420918 [TBL] [Abstract][Full Text] [Related]
10. Comparison of Flexor Tendon Repair Between 6-Strand Lim-Tsai With 4-Strand Cruciate and Becker Technique. Wong YR; Lee CS; Loke AM; Liu X; Suzana MJ I; Tay SC J Hand Surg Am; 2015 Sep; 40(9):1806-11. PubMed ID: 26142080 [TBL] [Abstract][Full Text] [Related]
11. A Hybrid Electrospun-Extruded Polydioxanone Suture for Tendon Tissue Regeneration. Abhari RE; Snelling SJB; Augustynak E; Davis S; Fischer R; Carr AJ; Mouthuy PA Tissue Eng Part A; 2024 Mar; 30(5-6):214-224. PubMed ID: 38126344 [TBL] [Abstract][Full Text] [Related]
12. An Exploratory Study Using Semi-Tabular Plate in Zone II Flexor Tendon Repair. Wong YR; Jais ISM; Chang MK; Lim BH; Tay SC J Hand Surg Asian Pac Vol; 2018 Dec; 23(4):547-553. PubMed ID: 30428798 [TBL] [Abstract][Full Text] [Related]
13. A new modified Tsuge suture for flexor tendon repairs: the biomechanical analysis and clinical application. Chen J; Wang K; Katirai F; Chen Z J Orthop Surg Res; 2014 Dec; 9():136. PubMed ID: 25551285 [TBL] [Abstract][Full Text] [Related]
14. Comparison of mechanical properties of polyvinylidene fluoride and polypropylene monofilament sutures used for flexor tendon repair. Wada A; Kubota H; Hatanaka H; Miura H; Iwamoto Y J Hand Surg Br; 2001 Jun; 26(3):212-6. PubMed ID: 11386769 [TBL] [Abstract][Full Text] [Related]
15. A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair. Lawrence TM; Davis TR J Hand Surg Am; 2005 Jul; 30(4):836-41. PubMed ID: 16039381 [TBL] [Abstract][Full Text] [Related]
16. [Experimental in vitro studies of the stability of tendon sutures]. Schulz-Gebhard B; Havemann D Aktuelle Traumatol; 1991 Aug; 21(4):153-6. PubMed ID: 1681702 [TBL] [Abstract][Full Text] [Related]
17. Flexor digitorum profundus tendon-to-bone repair: an ex vivo biomechanical analysis of 3 pullout suture techniques. Silva MJ; Hollstien SB; Brodt MD; Boyer MI; Tetro AM; Gelberman RH J Hand Surg Am; 1998 Jan; 23(1):120-6. PubMed ID: 9523965 [TBL] [Abstract][Full Text] [Related]
18. Effects of PDGF-BB delivery from heparinized collagen sutures on the healing of lacerated chicken flexor tendon in vivo. Younesi M; Knapik DM; Cumsky J; Donmez BO; He P; Islam A; Learn G; McClellan P; Bohl M; Gillespie RJ; Akkus O Acta Biomater; 2017 Nov; 63():200-209. PubMed ID: 28890257 [TBL] [Abstract][Full Text] [Related]
19. A randomised comparison of polydioxanone (PDS) and polypropylene (Prolene) for abdominal wound closure. Cameron AE; Parker CJ; Field ES; Gray RC; Wyatt AP Ann R Coll Surg Engl; 1987 May; 69(3):113-5. PubMed ID: 3111339 [TBL] [Abstract][Full Text] [Related]