These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
112 related articles for article (PubMed ID: 7608399)
21. Effect of Round Window Reinforcement on Hearing: A Temporal Bone Study With Clinical Implications for Surgical Reinforcement of the Round Window. Wegner I; Eldaebes MM; Landry TG; Adamson RB; Grolman W; Bance ML Otol Neurotol; 2016 Jun; 37(5):598-601. PubMed ID: 27050655 [TBL] [Abstract][Full Text] [Related]
22. Measurement of stapes vibration in Human temporal bones by round window stimulation using a 3-coil transducer. Shin DH; Kim DW; Lim HG; Jung ES; Seong KW; Lee JH; Kim MN; Cho JH Biomed Mater Eng; 2014; 24(1):405-11. PubMed ID: 24211922 [TBL] [Abstract][Full Text] [Related]
23. Mechanics of type IV tympanoplasty: experimental findings and surgical implications. Merchant SN; Ravicz ME; Rosowski JJ Ann Otol Rhinol Laryngol; 1997 Jan; 106(1):49-60. PubMed ID: 9006362 [TBL] [Abstract][Full Text] [Related]
24. Workshop: direct electrical stimulation of the inner ear for the relief of tinnitus. Balkany T; Bantli H; Vernon J; Douek E; Shulman A; House J; Portmann M; House W Am J Otol; 1987 May; 8(3):207-12. PubMed ID: 3498369 [No Abstract] [Full Text] [Related]
25. [Importance of the membrane of the round window and of the stapes in the experimental determination of the perilymphatic pressure]. FINOCCHI G Clin Otorinolaringoiatr; 1951 Oct; 3(5):347-56. PubMed ID: 14896500 [No Abstract] [Full Text] [Related]
26. Physiological assessment of active middle ear implant coupling to the round window in Chinchilla lanigera. Lupo JE; Koka K; Hyde BJ; Jenkins HA; Tollin DJ Otolaryngol Head Neck Surg; 2011 Oct; 145(4):641-7. PubMed ID: 21593462 [TBL] [Abstract][Full Text] [Related]
27. [The biology of the inner ear]. Arch Otorhinolaryngol Suppl; 1985; 2():52-73. PubMed ID: 3008688 [No Abstract] [Full Text] [Related]
28. Individual differences in the permeability of the round window: evaluating the movement of intratympanic gadolinium into the inner ear. Yoshioka M; Naganawa S; Sone M; Nakata S; Teranishi M; Nakashima T Otol Neurotol; 2009 Aug; 30(5):645-8. PubMed ID: 19415042 [TBL] [Abstract][Full Text] [Related]
29. Congenital perilymphatic fistula: computed tomography appearance of middle ear and inner ear anomalies. Weissman JL; Weber PC; Bluestone CD Otolaryngol Head Neck Surg; 1994 Sep; 111(3 Pt 1):243-9. PubMed ID: 8084632 [TBL] [Abstract][Full Text] [Related]
30. A 3D-printed functioning anatomical human middle ear model. Kuru I; Maier H; Müller M; Lenarz T; Lueth TC Hear Res; 2016 Oct; 340():204-213. PubMed ID: 26772730 [TBL] [Abstract][Full Text] [Related]
31. Is the pressure difference between the oval and round windows the effective acoustic stimulus for the cochlea? Voss SE; Rosowski JJ; Peake WT J Acoust Soc Am; 1996 Sep; 100(3):1602-16. PubMed ID: 8817890 [TBL] [Abstract][Full Text] [Related]
32. The influence of a cochlear implant electrode on the mechanical function of the inner ear. Huber AM; Hoon SJ; Sharouz B; Daniel B; Albrecht E Otol Neurotol; 2010 Apr; 31(3):512-8. PubMed ID: 20061991 [TBL] [Abstract][Full Text] [Related]
33. [Rupture of the membrane of the round window in stapes fixation]. Gungl M; Bauer M HNO; 1987 Nov; 35(11):482-4. PubMed ID: 3692935 [TBL] [Abstract][Full Text] [Related]
34. Non-syndromal round window atresia: an autosomal dominant genetic disorder with variable penetrance? Borrmann A; Arnold W Eur Arch Otorhinolaryngol; 2007 Sep; 264(9):1103-8. PubMed ID: 17476517 [TBL] [Abstract][Full Text] [Related]
35. Testing a method for quantifying the output of implantable middle ear hearing devices. Rosowski JJ; Chien W; Ravicz ME; Merchant SN Audiol Neurootol; 2007; 12(4):265-76. PubMed ID: 17406105 [TBL] [Abstract][Full Text] [Related]
36. On a novel type of neuron with proposed mechanoreceptor function in the human round window membrane--an immunohistochemical study. Rask-Andersen H; Kinnefors A; Illing RB Rev Laryngol Otol Rhinol (Bord); 1999; 120(3):203-7. PubMed ID: 10544681 [TBL] [Abstract][Full Text] [Related]
37. The pathway enabling external sounds to reach and excite the fetal inner ear. Sohmer H; Perez R; Sichel JY; Priner R; Freeman S Audiol Neurootol; 2001; 6(3):109-16. PubMed ID: 11474136 [TBL] [Abstract][Full Text] [Related]
38. [Study on the effects of hyaluronic acid-streptomycin perfusion through the round window on the function and morphology in guinea pig inner ears]. Yin T; Lu Y; Chen Z; Ren J; Xie D; Yang X; Tan W; Zhu D Hunan Yi Ke Da Xue Xue Bao; 1998; 23(2):133-6. PubMed ID: 10681824 [TBL] [Abstract][Full Text] [Related]
39. Bone conduction in Thiel-embalmed cadaver heads. Guignard J; Stieger C; Kompis M; Caversaccio M; Arnold A Hear Res; 2013 Dec; 306():115-22. PubMed ID: 24161399 [TBL] [Abstract][Full Text] [Related]
40. [Effect of variations in middle ear pressure on ruptures of the round window membrane of the inner ear of the guinea pig (Cavia porcellus)]. Mertens J HNO; 1995 Oct; 43(10):611-8. PubMed ID: 7499167 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]