BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 7617913)

  • 1. [Stereotactic radiotherapy with linear accelerators. Dosage considerations on collimators and photon beam energy].
    Somigliana AB; Filice S; Stucchi C; Gramaglia A; Villa S; Pasqualotto C; Brusa A; Crippa M; Casolino D; Scorsetti M
    Radiol Med; 1995 May; 89(5):692-4. PubMed ID: 7617913
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Beam characteristics and stopping-power ratios of small radiosurgery photon beams.
    Ding GX; Ding F
    Phys Med Biol; 2012 Sep; 57(17):5509-21. PubMed ID: 22872136
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A theoretical approach for non-equilibrium radiation dosimetry.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2008 Jul; 53(13):3493-9. PubMed ID: 18552420
    [TBL] [Abstract][Full Text] [Related]  

  • 5. On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator.
    Tsechanski A; Krutman Y; Faermann S
    Phys Med Biol; 2005 Dec; 50(23):5629-39. PubMed ID: 16306657
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Stereotactic radiosurgery using a linear accelerator (LINAC): simulation and positioning].
    Takayama M; Nakamura M; Ikezaki H; Ikeda I; Kusuda J; Furuya Y; Hara M; Saito I
    No Shinkei Geka; 1995 Mar; 23(3):223-8. PubMed ID: 7700490
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric characteristics of unflattened 6 MV photon beams of a clinical linear accelerator: a Monte Carlo study.
    Mesbahi A
    Appl Radiat Isot; 2007 Sep; 65(9):1029-36. PubMed ID: 17616465
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A mathematical description of the relative dosage distributions of stereotactic collimator tubes in 6-MV photon radiation].
    Müller J; Leetz HK; Vogelgesang U
    Strahlenther Onkol; 1993 Nov; 169(11):668-71. PubMed ID: 8248843
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code.
    Panettieri V; Duch MA; Jornet N; Ginjaume M; Carrasco P; Badal A; Ortega X; Ribas M
    Phys Med Biol; 2007 Jan; 52(1):303-16. PubMed ID: 17183143
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC).
    du Plessis FC; Leal A; Stathakis S; Xiong W; Ma CM
    Phys Med Biol; 2006 Apr; 51(8):2113-29. PubMed ID: 16585849
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
    Sikora M; Dohm O; Alber M
    Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Absorbed dose from contaminant electrons inside and outside megavoltage photon beams.
    Raffaele L; Ielo I; Settineri N; Tosi G; Brambilla MG; Cattani F
    Radiol Med; 1993 Oct; 86(4):513-20. PubMed ID: 8248591
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning.
    Babic S; McNiven A; Battista J; Jordan K
    Phys Med Biol; 2009 Apr; 54(8):2463-81. PubMed ID: 19336848
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Head scatter factors for small MV photon fields. Part II: the effects of source size and detector.
    McKerracher C; Thwaites DI
    Radiother Oncol; 2007 Nov; 85(2):286-91. PubMed ID: 17983678
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator.
    Wiezorek T; Voigt A; Metzger N; Georg D; Schwedas M; Salz H; Wendt TG
    Strahlenther Onkol; 2008 Feb; 184(2):73-9. PubMed ID: 18259698
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a Monte Carlo model for the Brainlab microMLC.
    Belec J; Patrocinio H; Verhaegen F
    Phys Med Biol; 2005 Mar; 50(5):787-99. PubMed ID: 15798255
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiation dosimetry of 12 MV photons from a CGR Therac 20 MeV Saturne linear accelerator.
    Nair RP
    Strahlentherapie; 1984 Oct; 160(10):612-6. PubMed ID: 6495354
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Generation and modelling of megavoltage photon beams for contrast-enhanced radiation therapy.
    Robar JL
    Phys Med Biol; 2006 Nov; 51(21):5487-504. PubMed ID: 17047265
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Dosimetric characterization of a multileaf collimator].
    Stasi M; Baiotto B; Palamara F; Gabriele P; Scielzo G
    Radiol Med; 1999 May; 97(5):382-8. PubMed ID: 10432971
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam.
    Mesbahi A
    Appl Radiat Isot; 2009 Jan; 67(1):55-60. PubMed ID: 18760613
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.