These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 7628030)

  • 1. Stability of the arterial to end-tidal carbon dioxide difference during anaesthesia for prolonged neurosurgical procedures.
    Sharma SK; McGuire GP; Cruise CJ
    Can J Anaesth; 1995 Jun; 42(6):498-503. PubMed ID: 7628030
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Arterial to end-tidal carbon dioxide difference during craniotomy in severely head-injured patients.
    Ferber J; Juniewicz HM; Lechowicz-Głogowska EB; Pieniek R; Wroński J
    Folia Med Cracov; 2001; 42(4):141-52. PubMed ID: 12815773
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The arterial to end-tidal carbon dioxide difference in neurosurgical patients during craniotomy.
    Russell GB; Graybeal JM
    Anesth Analg; 1995 Oct; 81(4):806-10. PubMed ID: 7574014
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measuring the human ventilatory and cerebral blood flow response to CO2: a technical consideration for the end-tidal-to-arterial gas gradient.
    Tymko MM; Hoiland RL; Kuca T; Boulet LM; Tremblay JC; Pinske BK; Williams AM; Foster GE
    J Appl Physiol (1985); 2016 Jan; 120(2):282-96. PubMed ID: 26542522
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of end-tidal CO2 measurement through the nose and pharynx in nonintubated patients during digital subtraction cerebral angiography.
    Zhang C; Wang M; Wang R; Wang W
    J Neurosurg Anesthesiol; 2013 Apr; 25(2):191-6. PubMed ID: 23269088
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correlation of arterial PCO2 and PETCO2 in prehospital controlled ventilation.
    Belpomme V; Ricard-Hibon A; Devoir C; Dileseigres S; Devaud ML; Chollet C; Marty J
    Am J Emerg Med; 2005 Nov; 23(7):852-9. PubMed ID: 16291440
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of end-tidal PCO2 and average alveolar expired PCO2 during positive end-expiratory pressure.
    Breen PH; Mazumdar B; Skinner SC
    Anesth Analg; 1996 Feb; 82(2):368-73. PubMed ID: 8561343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stability of the intraoperative arterial to end-tidal carbon dioxide partial pressure difference in children with congenital heart disease.
    Lazzell VA; Burrows FA
    Can J Anaesth; 1991 Oct; 38(7):859-65. PubMed ID: 1742819
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Arterial to end-tidal carbon dioxide difference during laparoscopy].
    Yusa T; Sasara T; Shimabukuro T; Higa Y
    Masui; 1992 Feb; 41(2):232-7. PubMed ID: 1532432
    [TBL] [Abstract][Full Text] [Related]  

  • 10. End-tidal carbon dioxide measurement in infants and children during and after general anaesthesia.
    Campbell FA; McLeod ME; Bissonnette B; Swartz JS
    Can J Anaesth; 1994 Feb; 41(2):107-10. PubMed ID: 8131224
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Changes in PCO2 with acute changes in cardiac index.
    Wahba RW; Tessler MJ; Béïque F; Kleiman SJ
    Can J Anaesth; 1996 Mar; 43(3):243-5. PubMed ID: 8829863
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of transcutaneous end-tidal and arterial measurements of carbon dioxide during general anaesthesia.
    Reid CW; Martineau RJ; Miller DR; Hull KA; Baines J; Sullivan PJ
    Can J Anaesth; 1992 Jan; 39(1):31-6. PubMed ID: 1733530
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gastric mucosal-to-end-tidal PCO2 difference during major abdominal surgery: influence of the arterial-to-end-tidal PCO2 difference?
    Lebuffe G; Onimus T; Vallet B
    Eur J Anaesthesiol; 2003 Feb; 20(2):147-52. PubMed ID: 12622500
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Misleading end-tidal CO2 tensions.
    Wahba RW; Tessler MJ
    Can J Anaesth; 1996 Aug; 43(8):862-6. PubMed ID: 8840067
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparing arterial and end-tidal carbon dioxide values in hyperventilated neurosurgical patients.
    Christensen MA; Bloom J; Sutton KR
    Am J Crit Care; 1995 Mar; 4(2):116-21. PubMed ID: 7749443
    [TBL] [Abstract][Full Text] [Related]  

  • 16. End-tidal estimates of arterial PCO2 for cardiac output measurement by CO2 rebreathing: a study in patients with cystic fibrosis and healthy controls.
    Pianosi P; Hochman J
    Pediatr Pulmonol; 1996 Sep; 22(3):154-60. PubMed ID: 8893253
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Concordance of end-tidal carbon dioxide and arterial carbon dioxide in severe traumatic brain injury.
    Lee SW; Hong YS; Han C; Kim SJ; Moon SW; Shin JH; Baek KJ
    J Trauma; 2009 Sep; 67(3):526-30. PubMed ID: 19741395
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of end-tidal PCO2 and transcutaneous PCO2 as noninvasive measurement of arterial PCO2 in extubated patients recovering from general anesthesia.
    Kavanagh BP; Sandler AN; Turner KE; Wick V; Lawson S
    J Clin Monit; 1992 Jul; 8(3):226-30. PubMed ID: 1494929
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of temperature correction of blood gas values on the accuracy of end-tidal carbon dioxide monitoring in children after cardiac surgery.
    Suominen PK; Stayer S; Wang W; Chang AC
    ASAIO J; 2007; 53(6):670-4. PubMed ID: 18043144
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of end-tidal PCO2 measurements using a sidestream capnometer in infants and children ventilated with the Sechrist infant ventilator.
    Hillier SC; Badgwell JM; McLeod ME; Creighton RE; Lerman J
    Can J Anaesth; 1990 Apr; 37(3):318-21. PubMed ID: 2108813
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.