These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 7632868)

  • 1. [Measurement and analysis of monophasic action potentials using fractally coated electrodes--I].
    Fröhlich R; Wetzig T; Bolz A; Schaldach M
    Biomed Tech (Berl); 1995 Jun; 40(6):154-9. PubMed ID: 7632868
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Measurement and analysis of monophasic action potentials using fractally coated electrodes--II].
    Wetzig T; Fröhlich R; Bolz A; Göhl K; Richter P; Gottwik M; Schaldach M
    Biomed Tech (Berl); 1995 Jun; 40(6):160-7. PubMed ID: 7632869
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intraoperative recordings of monophasic action potentials with chronically implantable pacemaker leads.
    Zrenner B; Müssig D; Schreieck J; Weyerbrock S; Schneider M; Schaldach M; Schömig A; Schmitt C
    Pacing Clin Electrophysiol; 1998 Jan; 21(1 Pt 2):235-8. PubMed ID: 9474679
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The recording of monophasic action potentials with fractal-coated iridium electrodes in humans.
    Zrenner B; Ndrepepa G; Müssig D; Stöbe C; Schneider MA; Karch MR; Plewan A; Schömig A; Schmitt C
    Pacing Clin Electrophysiol; 2000 Jan; 23(1):54-62. PubMed ID: 10666754
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simultaneous recordings of the monophasic action potential with silver chloride- and Ir-coated electrodes.
    Merkely B; Lang V; Gellér L; Ströbel JP; Kiss O; Fazekas L; Vecsey T; Horkay F; Juhász-Nagy A; Schaldach M
    Pacing Clin Electrophysiol; 1998 Jan; 21(1 Pt 2):231-4. PubMed ID: 9474678
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimizing the geometry of implantable leads for recording the monophasic action potential with fractally coated electrodes.
    Lang V; Merkely B; Gellér L; Kiss O; Ströbel JP; Schaldach M
    Pacing Clin Electrophysiol; 1998 Jan; 21(1 Pt 2):227-30. PubMed ID: 9474677
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low polarization pacing lead for detecting the ventricular-evoked response.
    Bolz A; Hubmann M; Hardt R; Riedmüller J; Schaldach M
    Med Prog Technol; 1993; 19(3):129-37. PubMed ID: 8127278
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A fractally coated, 1.3 mm2 high impedance pacing electrode.
    Fröhlig G; Bolz A; Ströbel J; Rutz M; Lawall P; Schwerdt H; Schaldach M; Schieffer H
    Pacing Clin Electrophysiol; 1998 Jun; 21(6):1239-46. PubMed ID: 9633066
    [TBL] [Abstract][Full Text] [Related]  

  • 9. P wave recognition and atrial stimulation with fractally iridium coated VDD single pass leads.
    Res JC; Reijsoo FJ; van Woersem RJ; Middelhoff CJ; van Kalmthout PM; Zwart P; Westendorp P
    Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):1883-8. PubMed ID: 7845786
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fractally coated myocardial pacemaker leads in children.
    Borth-Bruhns T; Gass M
    J Interv Card Electrophysiol; 2005 Oct; 14(1):37-43. PubMed ID: 16311937
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanism of degradation of AgCl coating on biopotential sensors.
    Shih CC; Shih CM; Chou KY; Lin SJ; Su YY; Gerhardt RA
    J Biomed Mater Res A; 2007 Sep; 82(4):872-83. PubMed ID: 17335017
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Titanium nitride cardiac pacemaker electrodes].
    Schaldach M; Hubmann M; Hardt R; Weikl A
    Biomed Tech (Berl); 1989; 34(7-8):185-90. PubMed ID: 2775825
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Analysis of myocardial evoked potentials in relation to ergometric load and heart rate for use in frequency-adaptive cardiac pacemakers].
    Wetzig T; Fischer G; Worth H; Hardt R; Hubmann M; Bolz A; Schaldach M
    Biomed Tech (Berl); 1995; 40(1-2):9-13. PubMed ID: 7703348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [The electrode-myocardium interface at the cellular level and prospects of the use of implantable pacemakers].
    Shal'dakh M
    Med Tekh; 1995; (5):9-20. PubMed ID: 8618541
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improvement of the Biocompatibility and Potential Stability of Chronically Implanted Electrodes Incorporating Coating Cell Membranes.
    Wang B; Yang P; Ding Y; Qi H; Gao Q; Zhang C
    ACS Appl Mater Interfaces; 2019 Mar; 11(9):8807-8817. PubMed ID: 30741520
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A review of bioelectrodes for clinical electrophysiologists.
    Iravanian S; Langberg JJ
    Heart Rhythm; 2019 Mar; 16(3):460-469. PubMed ID: 30261292
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prevention of the rapid degradation of subcutaneously implanted Ag/AgCl reference electrodes using polymer coatings.
    Moussy F; Harrison DJ
    Anal Chem; 1994 Mar; 66(5):674-9. PubMed ID: 8154589
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Steroid-eluting and fractally coated electrodes in children with high pacing thresholds.
    Sinha AM; Breithardt OA; Vazquez-Jimenez JF; Birkenhauer F; Schauerte P; Stellbrink C
    Thorac Cardiovasc Surg; 2002 Aug; 50(4):247-9. PubMed ID: 12165875
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chronic animal testing of new cardiac pacing electrodes.
    Adler S; Spehr P; Allen J; Block W
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1896-900. PubMed ID: 1704563
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Some aspects of energy-saving pacing in the light of the author's studies].
    Machejek J; Machejek J; Lelakowska-Pieła M; Engel A; Domaracki D; Lelakowski J
    Pol Merkur Lekarski; 2015 Aug; 39(230):81-5. PubMed ID: 26319380
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.