BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 7634578)

  • 1. Reaming technique of the femoral diaphysis in cementless total hip arthroplasty.
    Otani T; Whiteside LA; White SE; McCarthy DS
    Clin Orthop Relat Res; 1995 Feb; (311):210-21. PubMed ID: 7634578
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Failure of cementless fixation of the femoral component in total hip arthroplasty.
    Otani T; Whiteside LA
    Orthop Clin North Am; 1992 Apr; 23(2):335-46. PubMed ID: 1570145
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of neck resection on torsional stability of cementless total hip replacement.
    Whiteside LA; White SE; McCarthy DS
    Am J Orthop (Belle Mead NJ); 1995 Oct; 24(10):766-70. PubMed ID: 8593558
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Torsional fixation of the femoral component in total hip arthroplasty. The effect of surgical press-fit technique.
    Sugiyama H; Whiteside LA; Engh CA
    Clin Orthop Relat Res; 1992 Feb; (275):187-93. PubMed ID: 1735211
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Torsional fixation of a modular femoral hip component.
    Ohl MD; Whiteside LA; McCarthy DS; White SE
    Clin Orthop Relat Res; 1993 Feb; (287):135-41. PubMed ID: 8448932
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of collar and distal stem fixation on micromotion of the femoral stem in uncemented total hip arthroplasty.
    Whiteside LA; Easley JC
    Clin Orthop Relat Res; 1989 Feb; (239):145-53. PubMed ID: 2912614
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Personal experience with the Wagner revision stem in hip joint reoperations].
    Cech O; Stehlík J; Krbec M; Vrecion V
    Acta Chir Orthop Traumatol Cech; 2001; 68(3):148-61. PubMed ID: 11706537
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of distal stem geometry on interface motion in uncemented revision total hip prostheses.
    Kirk KL; Potter BK; Lehman RA; Xenos JS
    Am J Orthop (Belle Mead NJ); 2007 Oct; 36(10):545-9. PubMed ID: 18033566
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bending stiffness, torsional stability, and insertion force of cementless femoral stems.
    Incavo SJ; Johnson CC; Churchill DL; Beynnon BD
    Am J Orthop (Belle Mead NJ); 2001 Apr; 30(4):323-7. PubMed ID: 11334454
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis.
    Meneghini RM; Hallab NJ; Berger RA; Jacobs JJ; Paprosky WG; Rosenberg AG
    J Orthop Surg Res; 2006 Oct; 1():5. PubMed ID: 17150125
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The use of a hydroxyapatite-coated primary stem in revision total hip arthroplasty.
    Kelly SJ; Incavo SJ; Beynnon B
    J Arthroplasty; 2006 Jan; 21(1):64-71. PubMed ID: 16446187
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cementless S-ROM femoral component: effect of stem length on stability after extended proximal femoral osteotomy.
    Bhagia UT; Corpe RS; Steflik DE; Young TR; Schnars J
    J South Orthop Assoc; 2001; 10(1):6-11. PubMed ID: 12132846
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Femoral strut allografts in cementless revision total hip arthroplasty.
    Pak JH; Paprosky WG; Jablonsky WS; Lawrence JM
    Clin Orthop Relat Res; 1993 Oct; (295):172-8. PubMed ID: 8403644
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Long-term results of the Schenker cementless femoral component].
    Dzupa V; Cech O; Sesták M; Klézl Z
    Acta Chir Orthop Traumatol Cech; 2004; 71(2):93-100. PubMed ID: 15151096
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rotational stability of noncemented total hip femoral components.
    Whiteside LA; McCarthy DS; White SE
    Am J Orthop (Belle Mead NJ); 1996 Apr; 25(4):276-80. PubMed ID: 8728364
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effects of the collar on total hip femoral component subsidence.
    Whiteside LA; Amador D; Russell K
    Clin Orthop Relat Res; 1988 Jun; (231):120-6. PubMed ID: 3370866
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loads.
    Otani T; Whiteside LA; White SE
    J Biomed Mater Res; 1993 May; 27(5):575-85. PubMed ID: 8314810
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of a cementless femoral component for the management of bone loss in revision hip arthroplasty.
    Michelinakis E; Papapolychronlou T; Vafiadis J
    Bull Hosp Jt Dis; 1996; 55(1):28-32. PubMed ID: 8771351
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modified transfemoral approach to revision arthroplasty with uncemented modular revision stems.
    Fink B; Grossmann A
    Oper Orthop Traumatol; 2007 Mar; 19(1):32-55. PubMed ID: 17345026
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.