These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

313 related articles for article (PubMed ID: 7634588)

  • 1. The origin of submicron polyethylene wear debris in total hip arthroplasty.
    McKellop HA; Campbell P; Park SH; Schmalzried TP; Grigoris P; Amstutz HC; Sarmiento A
    Clin Orthop Relat Res; 1995 Feb; (311):3-20. PubMed ID: 7634588
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Etiology of osteolysis around porous-coated cementless total hip arthroplasties.
    Jasty M; Bragdon C; Jiranek W; Chandler H; Maloney W; Harris WH
    Clin Orthop Relat Res; 1994 Nov; (308):111-26. PubMed ID: 7955673
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris.
    Bobyn JD; Jacobs JJ; Tanzer M; Urban RM; Aribindi R; Sumner DR; Turner TM; Brooks CE
    Clin Orthop Relat Res; 1995 Feb; (311):21-39. PubMed ID: 7634577
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Polyethylene wear in periprosthetic tissue of failed cemented total hip arthroplasties].
    Wang Y; Dai K; Zhang P
    Zhonghua Wai Ke Za Zhi; 1997 Aug; 35(8):459-61. PubMed ID: 10678063
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators.
    Tipper JL; Galvin AL; Williams S; McEwen HM; Stone MH; Ingham E; Fisher J
    J Biomed Mater Res A; 2006 Sep; 78(3):473-80. PubMed ID: 16721797
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.
    Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A
    Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Method for assessment of distribution of UHMWPE wear particles in periprosthetic tissues in total hip arthroplasty].
    Pokorný D; Slouf M; Horák Z; Jahoda D; Entlicher G; Eklová S; Sosna A
    Acta Chir Orthop Traumatol Cech; 2006 Aug; 73(4):243-50. PubMed ID: 17026883
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanism of failure in hips with an uncemented, all polyethylene socket.
    Llinás A; Sarmiento A; Ebramzadeh E; Park SH; Campbell P; McKellop HA
    Clin Orthop Relat Res; 1999 May; (362):145-55. PubMed ID: 10335293
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses.
    Schmalzried TP; Jasty M; Rosenberg A; Harris WH
    J Appl Biomater; 1994; 5(3):185-90. PubMed ID: 10147443
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [New metod for quantification of UHMWPE wear particles around joint replacements].
    Pokorný D; Slouf M; Dybal J; Zolotarevová E; Veselý F; Jahoda D; Vavrík P; Landor I; Entlicher G; Sosna A
    Acta Chir Orthop Traumatol Cech; 2009 Oct; 76(5):374-81. PubMed ID: 19912700
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components.
    Coathup MJ; Blackburn J; Goodship AE; Cunningham JL; Smith T; Blunn GW
    Biomaterials; 2005 Jul; 26(19):4161-9. PubMed ID: 15664643
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues.
    Campbell P; Ma S; Yeom B; McKellop H; Schmalzried TP; Amstutz HC
    J Biomed Mater Res; 1995 Jan; 29(1):127-31. PubMed ID: 7713952
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator.
    Firkins PJ; Tipper JL; Saadatzadeh MR; Ingham E; Stone MH; Farrar R; Fisher J
    Biomed Mater Eng; 2001; 11(2):143-57. PubMed ID: 11352113
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties.
    Mabrey JD; Afsar-Keshmiri A; Engh GA; Sychterz CJ; Wirth MA; Rockwood CA; Agrawal CM
    J Biomed Mater Res; 2002; 63(5):475-83. PubMed ID: 12209890
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative analysis of UHMWPE wear debris isolated from the periprosthetic femoral tissues from a series of Charnley total hip arthroplasties.
    Bell J; Tipper JL; Ingham E; Stone MH; Wroblewski BM; Fisher J
    Biomed Mater Eng; 2002; 12(2):189-201. PubMed ID: 12122242
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.
    McKellop H; Shen FW; Lu B; Campbell P; Salovey R
    J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Micro-wear features on unique 100-Mrad cups: two retrieved cups compared to hip simulator wear study.
    Yamamoto K; Masaoka T; Manaka M; Oonishi H; Clarke I; Shoji H; Kawanabe K; Imakiire A
    Acta Orthop Scand; 2004 Apr; 75(2):134-41. PubMed ID: 15180227
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polyethylene wear debris in modular acetabular prostheses.
    Chen PC; Mead EH; Pinto JG; Colwell CW
    Clin Orthop Relat Res; 1995 Aug; (317):44-56. PubMed ID: 7671495
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene (UHMWPE) wear debris that provoke inflammation in a murine model of inflammation.
    Sieving A; Wu B; Mayton L; Nasser S; Wooley PH
    J Biomed Mater Res A; 2003 Mar; 64(3):457-64. PubMed ID: 12579559
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.