These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 7640971)

  • 1. Evaluation of a thin-film peripheral nerve cuff electrode.
    Walter JS; McLane J; Cai W; Khan T; Cogan S
    J Spinal Cord Med; 1995 Jan; 18(1):28-32. PubMed ID: 7640971
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chronic histological effects of the flat interface nerve electrode.
    Leventhal DK; Cohen M; Durand DM
    J Neural Eng; 2006 Jun; 3(2):102-13. PubMed ID: 16705266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Chronic measurement of the stimulation selectivity of the flat interface nerve electrode.
    Leventhal DK; Durand DM
    IEEE Trans Biomed Eng; 2004 Sep; 51(9):1649-58. PubMed ID: 15376513
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The design of and chronic tissue response to a composite nerve electrode with patterned stiffness.
    Freeberg MJ; Stone MA; Triolo RJ; Tyler DJ
    J Neural Eng; 2017 Jun; 14(3):036022. PubMed ID: 28287078
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes.
    Grill WM; Mortimer JT
    J Biomed Mater Res; 2000 May; 50(2):215-26. PubMed ID: 10679687
    [TBL] [Abstract][Full Text] [Related]  

  • 6. "Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves".
    Christie BP; Freeberg M; Memberg WD; Pinault GJC; Hoyen HA; Tyler DJ; Triolo RJ
    J Neuroeng Rehabil; 2017 Jul; 14(1):70. PubMed ID: 28693584
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stability of the input-output properties of chronically implanted multiple contact nerve cuff stimulating electrodes.
    Grill WM; Mortimer JT
    IEEE Trans Rehabil Eng; 1998 Dec; 6(4):364-73. PubMed ID: 9865883
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Subcutaneous Ports for Chronic Nerve Cuff and Intramuscular Electrode Stimulation in Animal Models.
    Heaton JT; Kobler JB; Ottensmeyer MP; Petrillo RH; Tynan MA; Hillman RE; Zeitels SM
    Otolaryngol Head Neck Surg; 2021 Apr; 164(4):821-828. PubMed ID: 32957852
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Acute in vivo testing of a polymer cuff electrode with integrated microfluidic channels for stimulation, recording, and drug delivery on rat sciatic nerve.
    Elyahoodayan S; Larson C; Cobo AM; Meng E; Song D
    J Neurosci Methods; 2020 Apr; 336():108634. PubMed ID: 32068010
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flexible, multichannel cuff electrode for selective electrical stimulation of the mouse trigeminal nerve.
    Bong J; Ness JP; Zeng W; Kim H; Novello J; Pisaniello J; Lake WB; Ludwig KA; Williams JC; Ma Z; Suminski AJ
    Biosens Bioelectron; 2019 Oct; 142():111493. PubMed ID: 31319324
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comments on "A Spiral Nerve Cuff Electrode for Peripheral Nerve Stimulation".
    Racz GB; Heavner JE
    IEEE Trans Biomed Eng; 1989 Nov; 36(11):1140-1. PubMed ID: 2624638
    [No Abstract]   [Full Text] [Related]  

  • 12. Selectivity of afferent microstimulation at the DRG using epineural and penetrating electrode arrays.
    Nanivadekar AC; Ayers CA; Gaunt RA; Weber DJ; Fisher LE
    J Neural Eng; 2019 Dec; 17(1):016011. PubMed ID: 31577993
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A spiral nerve cuff electrode for peripheral nerve stimulation.
    Naples GG; Mortimer JT; Scheiner A; Sweeney JD
    IEEE Trans Biomed Eng; 1988 Nov; 35(11):905-16. PubMed ID: 3198136
    [No Abstract]   [Full Text] [Related]  

  • 14. An intrafascicular electrode for recording of action potentials in peripheral nerves.
    Malagodi MS; Horch KW; Schoenberg AA
    Ann Biomed Eng; 1989; 17(4):397-410. PubMed ID: 2774314
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of external pressures generated by nerve cuff electrodes.
    Cuoco FA; Durand DM
    IEEE Trans Rehabil Eng; 2000 Mar; 8(1):35-41. PubMed ID: 10779106
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Technology and long-term application of an epineural electrode.
    Thoma H; Girsch W; Holle J; Mayr W
    ASAIO Trans; 1989; 35(3):490-4. PubMed ID: 2597515
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation.
    Restaino SM; Abliz E; Wachrathit K; Krauthamer V; Shah SB
    J Neuroeng Rehabil; 2014 Apr; 11():73. PubMed ID: 24758405
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves.
    Tyler DJ; Durand DM
    IEEE Trans Rehabil Eng; 1997 Mar; 5(1):51-61. PubMed ID: 9086385
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A biohybrid system to interface peripheral nerves after traumatic lesions: design of a high channel sieve electrode.
    Stieglitz T; Ruf HH; Gross M; Schuettler M; Meyer JU
    Biosens Bioelectron; 2002 Aug; 17(8):685-96. PubMed ID: 12052354
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve.
    Christensen MB; Pearce SM; Ledbetter NM; Warren DJ; Clark GA; Tresco PA
    Acta Biomater; 2014 Nov; 10(11):4650-4660. PubMed ID: 25042798
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.