BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 7641473)

  • 1. Cementless femoral components should be made from cobalt chrome.
    Sotereanos NG; Engh CA; Glassman AH; Macalino GE; Engh CA
    Clin Orthop Relat Res; 1995 Apr; (313):146-53. PubMed ID: 7641473
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mode of loosening of matt-finished femoral stems in primary total hip replacement.
    Behairy YM; Harris WH
    Saudi Med J; 2002 Oct; 23(10):1187-94. PubMed ID: 12436120
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Revision of loose cementless femoral prostheses to larger porous coated components.
    Engh CA; Culpepper WJ; Kassapidis E
    Clin Orthop Relat Res; 1998 Feb; (347):168-78. PubMed ID: 9520886
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Total hip arthroplasty. Concerns with extensively porous coated femoral components.
    McAuley JP; Culpepper WJ; Engh CA
    Clin Orthop Relat Res; 1998 Oct; (355):182-8. PubMed ID: 9917603
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Long-term results of the Schenker cementless femoral component].
    Dzupa V; Cech O; Sesták M; Klézl Z
    Acta Chir Orthop Traumatol Cech; 2004; 71(2):93-100. PubMed ID: 15151096
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Osteolysis around an uncemented cobalt chrome total hip arthroplasty.
    Xenos JS; Hopkinson WJ; Callaghan JJ; Heekin RD; Savory CG
    Clin Orthop Relat Res; 1995 Aug; (317):29-36. PubMed ID: 7671492
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Early aseptic loosening of the CF 30 femoral stem].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):59-64. PubMed ID: 17331456
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A second-generation cementless total hip arthroplasty mean 9-year results.
    Surdam JW; Archibeck MJ; Schultz SC; Junick DW; White RE
    J Arthroplasty; 2007 Feb; 22(2):204-9. PubMed ID: 17275634
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Should monobloc cemented stems be systematically revised during revision total hip arthroplasty? A prospective evaluation].
    Grosjean G; Courpied JP; Moindreau M; Hunou N; Mathieu M; Hamadouche M
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Nov; 94(7):670-7. PubMed ID: 18984124
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of stem size on clinical outcome of primary total hip arthroplasty with cementless extensively porous-coated femoral components.
    Engh CA; Mohan V; Nagowski JP; Sychterz Terefenko CJ; Engh CA
    J Arthroplasty; 2009 Jun; 24(4):554-9. PubMed ID: 18534449
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Extensively coated femoral components in young patients.
    Kronick JL; Barba ML; Paprosky WG
    Clin Orthop Relat Res; 1997 Nov; (344):263-74. PubMed ID: 9372777
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tapered titanium cementless total hip replacements: a 10- to 13-year followup study.
    Bourne RB; Rorabeck CH; Patterson JJ; Guerin J
    Clin Orthop Relat Res; 2001 Dec; (393):112-20. PubMed ID: 11764339
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register.
    Eskelinen A; Remes V; Helenius I; Pulkkinen P; Nevalainen J; Paavolainen P
    Acta Orthop; 2006 Feb; 77(1):57-70. PubMed ID: 16534703
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Second-generation porous-coated cementless total hip arthroplasties have high survival.
    Chen CJ; Xenos JS; McAuley JP; Young A; Engh CA
    Clin Orthop Relat Res; 2006 Oct; 451():121-7. PubMed ID: 16735872
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years.
    Jacobsen S; Jensen FK; Poulsen K; Stürup J; Retpen JB
    Acta Orthop Scand; 2003 Aug; 74(4):375-9. PubMed ID: 14521285
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Femoral revision hip arthroplasty with uncemented, porous-coated stems.
    Moreland JR; Bernstein ML
    Clin Orthop Relat Res; 1995 Oct; (319):141-50. PubMed ID: 7554623
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Extensively porous-coated stems for femoral revision: reliable choice for stem revision in Paprosky femoral type III defects.
    Chung LH; Wu PK; Chen CF; Chen WM; Chen TH; Liu CL
    Orthopedics; 2012 Jul; 35(7):e1017-21. PubMed ID: 22784893
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The isoelastic, noncemented total hip arthroplasty. Preliminary experience with 400 cases.
    Andrew TA; Flanagan JP; Gerundini M; Bombelli R
    Clin Orthop Relat Res; 1986 May; (206):127-38. PubMed ID: 3708965
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study.
    Kim YH; Kim JS; Cho SH
    J Bone Joint Surg Br; 2001 Jul; 83(5):742-50. PubMed ID: 11482320
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Loosening of cobalt chrome beads from a porous-coated acetabular component. A report of ten cases.
    Davey JR; Harris WH
    Clin Orthop Relat Res; 1988 Jun; (231):97-102. PubMed ID: 3370892
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.