  • 1. Bronchial obstruction secondary to aortic pseudoaneurysm: treatment with an expandable metallic stent.
    Weiss JP; Sexauer WP; Saab EM
    AJR Am J Roentgenol; 1995 Sep; 165(3):547-9. PubMed ID: 7645466
    [No Abstract]   [Full Text] [Related]  

  • 2. Compression of the left main bronchus by a huge descending thoracic aortic aneurysm.
    Nishimura Y; Okamura Y; Iwahashi M; Yuzaki M
    Eur J Cardiothorac Surg; 2006 Apr; 29(4):607. PubMed ID: 16481184
    [No Abstract]   [Full Text] [Related]  

  • 3. Rescue surgery for bronchial obstruction after endovascular thoracoabdominal stent implantation.
    Kiefer P; Seeburger J; Lehmkuhl L; Mohr FW
    J Thorac Cardiovasc Surg; 2011 Dec; 142(6):1581-2. PubMed ID: 21703640
    [No Abstract]   [Full Text] [Related]  

  • 4. Repair of thoracic aortic aneurysm associated with tracheal and right mainstem bronchus compression.
    Koomen E; Schurink GW; Mochtar B; Jacobs MJ; Smets RJ
    J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):88-90. PubMed ID: 17289487
    [No Abstract]   [Full Text] [Related]  

  • 5. The anesthetic management of a patient with a thoracic aortic aneurysm that caused compression of the left mainstem bronchus and the right pulmonary artery.
    Mori M; Chuma R; Kiichi Y; Masuda Y; Obara H
    J Cardiothorac Vasc Anesth; 1993 Oct; 7(5):579-84. PubMed ID: 8268440
    [No Abstract]   [Full Text] [Related]  

  • 6. [An adult case of bronchodilation using stents for right aortic arch].
    Maniwa Y; Yamamoto H; Omori T; Yamamoto H; Kujime K
    Nihon Kyobu Geka Gakkai Zasshi; 1994 Dec; 42(12):2292-6. PubMed ID: 7861072
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Successful removal of expandable metallic stent in a patient with lung cancer.
    Ose N; Inoue M; Minami M; Sawabata N; Kadota Y; Okumura M
    Asian Cardiovasc Thorac Ann; 2012 Apr; 20(2):202-4. PubMed ID: 22499973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Usefulness of Dumon-type endotracheal stent for left main bronchial obstruction caused by thoracic aortic aneurysm--a case report].
    Watanabe S; Toyohira H; Yamaoka A; Yotsumoto G; Shiota K; Taira A
    Nihon Kyobu Geka Gakkai Zasshi; 1996 Sep; 44(9):1776-80. PubMed ID: 8911055
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Successful Deployment of Two Balloon-Expandable Stents Using an In-Stent Bifurcating Approach.
    Cho RJ; Zamora FD; Gibson H; Dincer HE
    Ann Am Thorac Soc; 2018 Jul; 15(7):884-886. PubMed ID: 29957039
    [No Abstract]   [Full Text] [Related]  

  • 10. Scoliosis and bronchial obstruction.
    Qiabi M; Chagnon K; Beaupré A; Hercun J; Rakovich G
    Can Respir J; 2015; 22(4):206-8. PubMed ID: 26083538
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Expandable metallic stents applied to benign bronchostenosis.
    Satoh S; Mori M; Inoue Y
    Chest; 1993 Apr; 103(4):1302-3. PubMed ID: 8131499
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fatal complication of an expandable metallic bronchial stent.
    Wadsworth SJ; Juniper MC; Benson MK; Gleeson FV
    Br J Radiol; 1999 Jul; 72(859):706-8. PubMed ID: 10624330
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Metallic stents for rescuing a patient with severe upper airway compression due to aortic aneurysm.
    Chen WC; Tu CY; Liang SJ; Liu JC; Chen W
    Am J Emerg Med; 2009 Feb; 27(2):256.e1-4. PubMed ID: 19371558
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Positional dyspnoea due to aneurysm of the thoracic aorta.
    Phillips GD; Smith EE; Millard FJ
    Eur Respir J; 1994 Feb; 7(2):412-4. PubMed ID: 8162996
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Expandable metallic bronchial endoprosthesis.
    Asch MR; Jaffer NM
    Can Assoc Radiol J; 1995 Jun; 46(3):216-8. PubMed ID: 7538885
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Usefulness of expandable metallic stent to bronchial stenosis caused by an advanced lung cancer--a case report].
    Kawahira Y; Nakao K; Hamaji M; Nakahara M; Abe K; Ikezoe J
    Nihon Kyobu Geka Gakkai Zasshi; 1993 Apr; 41(4):704-8. PubMed ID: 8515175
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Unusual cause of wheezing: extrinsic bronchial compression by pulmonary artery aneurysm.
    Fernandes CJC; Jasinowodolinski D; Souza R
    Eur J Cardiothorac Surg; 2018 Nov; 54(5):965. PubMed ID: 29860280
    [No Abstract]   [Full Text] [Related]  

  • 18. Endobronchial and endovascular management of bronchial compression by a thoracic aortic aneurysm.
    Reed AB; Reed MF
    Ann Thorac Surg; 2012 Jul; 94(1):273-4. PubMed ID: 22734993
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Placement of an expandable metallic stent (Ultraflex) for tracheobronchial stenosis in relapsing polychondritis].
    Takagi M; Yamazi T; Yano H; Tai H
    Nihon Kokyuki Gakkai Zasshi; 2006 Dec; 44(12):997-1001. PubMed ID: 17233402
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [A case of bronchial stenosis due to postoperative inflammation treated with expandable metallic stent].
    Tabata S; Tanida T; Ono S; Noda M; Sato M; Sakuma T; Fujumura S
    Kyobu Geka; 1997 Jun; 50(6):507-10. PubMed ID: 9185452
    [TBL] [Abstract][Full Text] [Related]  