These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
96 related articles for article (PubMed ID: 7646146)
41. Comparison of Ross procedures and aortic valve allografts in children. Jones TK; Lupinetti FM Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S170-3. PubMed ID: 9930442 [TBL] [Abstract][Full Text] [Related]
42. Long term performance of 580 homograft and autograft valves used for aortic valve replacement. Bodnar E; Wain WH; Martelli V; Ross DN Thorac Cardiovasc Surg; 1979 Feb; 27(1):31-8. PubMed ID: 442059 [TBL] [Abstract][Full Text] [Related]
44. Comparative rest and exercise hemodynamics of allograft and prosthetic valves in the aortic position. Hasegawa J; Kitamura S; Taniguchi S; Kawata T; Niwaya K; Mizuguchi K; Nishioka H; Kameda Y Ann Thorac Surg; 1997 Dec; 64(6):1753-6. PubMed ID: 9436567 [TBL] [Abstract][Full Text] [Related]
45. Calcification of allograft and stentless xenograft valves for right ventricular outflow tract reconstruction: an experimental study in adolescent sheep. Flameng W; Jashari R; De Visscher G; Mesure L; Meuris B J Thorac Cardiovasc Surg; 2011 Jun; 141(6):1513-21. PubMed ID: 21093875 [TBL] [Abstract][Full Text] [Related]
46. In situ hybridization: a new technique to determine the origin of fibroblasts in cryopreserved aortic homograft valve explants. Hazekamp MG; Koolbergen DR; Braun J; Sugihara H; Cornelisse CJ; Goffin YA; Huysmans HA J Thorac Cardiovasc Surg; 1995 Jul; 110(1):248-57. PubMed ID: 7609548 [TBL] [Abstract][Full Text] [Related]
47. Freehand allograft aortic valve replacement and aortic root replacement. Utility of intraoperative echocardiography and Doppler color flow mapping. Bartzokis T; St Goar F; DiBiase A; Miller DC; Bolger AF J Thorac Cardiovasc Surg; 1991 Mar; 101(3):545-53; discussion 553-4. PubMed ID: 1999949 [TBL] [Abstract][Full Text] [Related]
48. Aortic valve replacement with homograft and autograft. Doty DB Semin Thorac Cardiovasc Surg; 1996 Jul; 8(3):249-58. PubMed ID: 8843516 [TBL] [Abstract][Full Text] [Related]
49. Fate of the autograft and homograft following Ross aortic valve replacement: reoperative frequency, outcome, and management. Brown JW; Ruzmetov M; Fukui T; Rodefeld MD; Mahomed Y; Turrentine MW J Heart Valve Dis; 2006 Mar; 15(2):253-9; discusson 259-60. PubMed ID: 16607909 [TBL] [Abstract][Full Text] [Related]
50. Aortic homografts versus mechanical valves in aortic valve replacement in young patients: a retrospective study. Gross C; Klima U; Mair R; Brücke P Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S194-7. PubMed ID: 9930447 [TBL] [Abstract][Full Text] [Related]
51. Recycling of the Pulmonary Autograft During Reverse Ross Operation: From Pulmonary Valve to Neoaortic Valve and Back. Schmiady M; Bettex D; Hübler M; Schweiger M World J Pediatr Congenit Heart Surg; 2019 Mar; 10(2):242-244. PubMed ID: 30651047 [TBL] [Abstract][Full Text] [Related]
52. Valve-related events after aortic root replacement with cryopreserved aortic homografts. Kaya A; Schepens MA; Morshuis WJ; Heijmen RH; Brutel de la Riviere A; Dossche KM Ann Thorac Surg; 2005 May; 79(5):1491-5. PubMed ID: 15854921 [TBL] [Abstract][Full Text] [Related]
53. Preseeding with autologous fibroblasts improves endothelialization of glutaraldehyde-fixed porcine aortic valves. Gulbins H; Goldemund A; Anderson I; Haas U; Uhlig A; Meiser B; Reichart B J Thorac Cardiovasc Surg; 2003 Mar; 125(3):592-601. PubMed ID: 12658201 [TBL] [Abstract][Full Text] [Related]
54. Replacement of the aortic valve with cryopreserved aortic allograft. Doty DB; Michielon G; Wang ND; Cain AS; Millar RC Ann Thorac Surg; 1993 Aug; 56(2):228-35; discussion 235-6. PubMed ID: 8347003 [TBL] [Abstract][Full Text] [Related]
55. Effect of cryopreservation on the presence of endothelial cells on human valve allografts. Lupinetti FM; Tsai TT; Kneebone JM; Bove EL J Thorac Cardiovasc Surg; 1993 Nov; 106(5):912-7. PubMed ID: 8231215 [TBL] [Abstract][Full Text] [Related]
56. Comparison of techniques for implantation of aortic valve allografts. Dearani JA; Orszulak TA; Daly RC; Phillips MR; Miller FA; Danielson GK; Schaff HV Ann Thorac Surg; 1996 Oct; 62(4):1069-75. PubMed ID: 8823091 [TBL] [Abstract][Full Text] [Related]
57. Tissue chimerism in human cryopreserved homograft valve explants demonstrated by in situ hybridization. Koolbergen DR; Hazekamp MG; Kurvers M; de Heer E; Cornelisse CJ; Huysmans HA; Bruijn JA Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S225-32. PubMed ID: 9930453 [TBL] [Abstract][Full Text] [Related]
58. Pediatric autograft aortic root replacement: a prospective follow-up study. Takkenberg JJ; Kappetein AP; van Herwerden LA; Witsenburg M; Van Osch-Gevers L; Bogers AJ Ann Thorac Surg; 2005 Nov; 80(5):1628-33. PubMed ID: 16242428 [TBL] [Abstract][Full Text] [Related]
59. Comparison of the aortic homograft and the pulmonary autograft for aortic valve or root replacement in children. Gerosa G; McKay R; Davies J; Ross DN J Thorac Cardiovasc Surg; 1991 Jul; 102(1):51-60; discussion 60-1. PubMed ID: 2072729 [TBL] [Abstract][Full Text] [Related]