These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
132 related articles for article (PubMed ID: 7646192)
21. Hemodynamic Performance of Endovascular Valves as Valve-in-Valve in Small Stented Bioprosthesis. Kuehnel RU; Hartrumpf M; Erb M; Albes JM Thorac Cardiovasc Surg; 2017 Apr; 65(3):225-230. PubMed ID: 27517167 [No Abstract] [Full Text] [Related]
22. The pulmonary valve. Is it mechanically suitable for use as an aortic valve replacement? David H; Boughner DR; Vesely I; Gerosa G ASAIO J; 1994; 40(2):206-12. PubMed ID: 8003760 [TBL] [Abstract][Full Text] [Related]
23. The mechanical properties of porcine aortic valve tissues. Sauren AA; van Hout MC; van Steenhoven AA; Veldpaus FE; Janssen JD J Biomech; 1983; 16(5):327-37. PubMed ID: 6885834 [TBL] [Abstract][Full Text] [Related]
24. Biomechanical and ultrastructural comparison of cryopreservation and a novel cellular extraction of porcine aortic valve leaflets. Courtman DW; Pereira CA; Omar S; Langdon SE; Lee JM; Wilson GJ J Biomed Mater Res; 1995 Dec; 29(12):1507-16. PubMed ID: 8600141 [TBL] [Abstract][Full Text] [Related]
25. Analysis of the Medtronic Intact bioprosthetic valve. Effects of "zero-pressure" fixation. Vesely I J Thorac Cardiovasc Surg; 1991 Jan; 101(1):90-9. PubMed ID: 1986174 [TBL] [Abstract][Full Text] [Related]
27. Estimation of Reynolds shear stresses during pulsatile flow in the region of aortic valves. Walburn FJ; Sabbah HN; Stein PD Ann Biomed Eng; 1985; 13(1):17-23. PubMed ID: 4003870 [TBL] [Abstract][Full Text] [Related]
28. Simulation of damage in a porcine prosthetic heart valve. Chew GG; Howard IC; Patterson EA J Med Eng Technol; 1999; 23(5):178-89. PubMed ID: 10627951 [TBL] [Abstract][Full Text] [Related]
29. Optimizing the tensile properties of polyvinyl alcohol hydrogel for the construction of a bioprosthetic heart valve stent. Wan WK; Campbell G; Zhang ZF; Hui AJ; Boughner DR J Biomed Mater Res; 2002; 63(6):854-61. PubMed ID: 12418034 [TBL] [Abstract][Full Text] [Related]
30. Is zero-pressure fixation of bioprosthetic valves truly stress free? Vesely I; Lozon A; Talman E J Thorac Cardiovasc Surg; 1993 Aug; 106(2):288-98. PubMed ID: 8341070 [TBL] [Abstract][Full Text] [Related]
31. A preliminary durability study of two types of low-profile pericardial bioprosthetic valves through the use of accelerated fatigue testing and flow characterization. Schuster PR; Wagner JW J Biomed Mater Res; 1989 Feb; 23(2):207-22. PubMed ID: 2708409 [TBL] [Abstract][Full Text] [Related]
32. The pulmonary bioprosthetic heart valve: its unsuitability for use as an aortic valve replacement. Jennings LM; Butterfield M; Booth C; Watterson KG; Fisher J J Heart Valve Dis; 2002 Sep; 11(5):668-78; discussion 679. PubMed ID: 12358404 [TBL] [Abstract][Full Text] [Related]
33. Comparative in-vitro fluid dynamics characterization of heart valve bioprostheses under accelerated fatigue conditions and under physiologic conditions. Iosif MC; Gabbay S Biomed Instrum Technol; 1993; 27(6):495-505. PubMed ID: 8275144 [TBL] [Abstract][Full Text] [Related]
34. Mechanical properties of porcine pulmonary valve leaflets: how do they differ from aortic leaflets? Christie GW; Barratt-Boyes BG Ann Thorac Surg; 1995 Aug; 60(2 Suppl):S195-9. PubMed ID: 7646158 [TBL] [Abstract][Full Text] [Related]