These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
112 related articles for article (PubMed ID: 7652005)
41. Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air. Rivard MJ; Granero D; Perez-Calatayud J; Ballester F Med Phys; 2010 Feb; 37(2):869-76. PubMed ID: 20229896 [TBL] [Abstract][Full Text] [Related]
42. The IPEM code of practice for determination of the reference air kerma rate for HDR (192)Ir brachytherapy sources based on the NPL air kerma standard. Bidmead AM; Sander T; Locks SM; Lee CD; Aird EG; Nutbrown RF; Flynn A; Phys Med Biol; 2010 Jun; 55(11):3145-59. PubMed ID: 20479510 [TBL] [Abstract][Full Text] [Related]
43. Calibration of the NPL secondary standard radionuclide calibrator for 192Ir brachytherapy sources. Sephton JP; Woods MJ; Rossiter MJ; Williams TT; Dean JC; Bass GA; Lucas SE Phys Med Biol; 1993 Aug; 38(8):1157-64. PubMed ID: 8367526 [TBL] [Abstract][Full Text] [Related]
44. Monte Carlo aided design of an improved well-type ionization chamber for low energy brachytherapy sources. Bohm TD; Micka JA; DeWerd LA Med Phys; 2007 Apr; 34(4):1274-85. PubMed ID: 17500459 [TBL] [Abstract][Full Text] [Related]
45. Dosimetry of 192Ir sources used for endovascular brachytherapy. Reynaert N; Van Eijkeren M; Taeymans Y; Thierens H Phys Med Biol; 2001 Feb; 46(2):499-516. PubMed ID: 11229729 [TBL] [Abstract][Full Text] [Related]
46. Air kerma standard for calibration of well-type chambers in Brazil using 192Ir HDR sources and its traceability. Di Prinzio R; DeAlmeida CE Med Phys; 2009 Mar; 36(3):953-60. PubMed ID: 19378756 [TBL] [Abstract][Full Text] [Related]
47. Study of scattered radiation for in-air calibration by a multiple-distance method using ionization chambers and an HDR 192Ir brachytherapy source. Patel NP; Majumdar B; Vijayan V Br J Radiol; 2006 Apr; 79(940):347-52. PubMed ID: 16585730 [TBL] [Abstract][Full Text] [Related]
49. Spectra and air-kerma strength for encapsulated 192Ir sources. Borg J; Rogers DW Med Phys; 1999 Nov; 26(11):2441-4. PubMed ID: 10587230 [TBL] [Abstract][Full Text] [Related]
50. Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources. Melhus CS; Rivard MJ Med Phys; 2006 Jun; 33(6):1729-37. PubMed ID: 16872080 [TBL] [Abstract][Full Text] [Related]
51. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system. Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095 [TBL] [Abstract][Full Text] [Related]
52. The wall correction factor for a spherical ionization chamber used in brachytherapy source calibration. Piermattei A; Azario L; Fidanzio A; Viola P; Dell'Omo C; Iadanza L; Fusco V; Lagares JI; Capote R Phys Med Biol; 2003 Dec; 48(24):4091-103. PubMed ID: 14727753 [TBL] [Abstract][Full Text] [Related]
53. Dose distributions and dose rate constants for new ytterbium-169 brachytherapy seeds. MacPherson MS; Battista JJ Med Phys; 1995 Jan; 22(1):89-96. PubMed ID: 7715573 [TBL] [Abstract][Full Text] [Related]
54. A standard dosimetry procedure for 192Ir sources used for endovascular brachytherapy. Piermattei A; Fidanzio A; Azario L; Russo A; Perrone F; Capote R; Toni MP Phys Med Biol; 2002 Dec; 47(23):4205-21. PubMed ID: 12502044 [TBL] [Abstract][Full Text] [Related]
55. Experimental derivation of the fluence non-uniformity correction for air kerma near brachytherapy linear sources. Vianello EA; deAlmeida CE Med Phys; 2008 Jul; 35(7):3389-92. PubMed ID: 18697563 [TBL] [Abstract][Full Text] [Related]
56. EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources. Taylor RE; Rogers DW Med Phys; 2008 Nov; 35(11):4933-44. PubMed ID: 19070227 [TBL] [Abstract][Full Text] [Related]
57. Correction factors for source strength determination in HDR brachytherapy using the in-phantom method. Ubrich F; Wulff J; Engenhart-Cabillic R; Zink K Z Med Phys; 2014 May; 24(2):138-52. PubMed ID: 24021956 [TBL] [Abstract][Full Text] [Related]
58. Recommendations of the American Association of Physicists in Medicine on 103Pd interstitial source calibration and dosimetry: implications for dose specification and prescription. Williamson JF; Coursey BM; DeWerd LA; Hanson WF; Nath R; Rivard MJ; Ibbott G Med Phys; 2000 Apr; 27(4):634-42. PubMed ID: 10798683 [TBL] [Abstract][Full Text] [Related]
59. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV). Tedgren AC; Hedman A; Grindborg JE; Carlsson GA Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372 [TBL] [Abstract][Full Text] [Related]
60. Dosimetric characteristics of the DRAXIMAGE model LS-1 1-125 interstitial brachytherapy source design: a Monte Carlo investigation. Williamson JF Med Phys; 2002 Apr; 29(4):509-21. PubMed ID: 11991122 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]