These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 7659590)
21. Isoelectric PVCs diagnosed with a monitor with simultaneous ECG, and ICD intracardiac electrogram and marker channels. Scher DL; Man DC; Edery T; Lu S Pacing Clin Electrophysiol; 2009 Jan; 32(1):137-9. PubMed ID: 19140925 [TBL] [Abstract][Full Text] [Related]
23. Incidence of ICD lead related complications during long-term follow-up: comparison of epicardial and endocardial electrode systems. Korte T; Jung W; Spehl S; Wolpert C; Moosdorf R; Manz M; Lüderitz B Pacing Clin Electrophysiol; 1995 Nov; 18(11):2053-61. PubMed ID: 8552520 [TBL] [Abstract][Full Text] [Related]
24. [Transvenous subcutaneous implantation technique of the cardioverter/defibrillator]. Block M; Hammel D; Borggrefe M; Scheld HH; Breithardt G Herz; 1994 Oct; 19(5):259-77. PubMed ID: 8001899 [TBL] [Abstract][Full Text] [Related]
25. Failure of a second and third generation implantable cardioverter defibrillator to sense ventricular tachycardia: implications for fixed-gain sensing devices. Sperry RE; Ellenbogen KA; Wood MA; Stambler BS; DiMarco JP; Haines DE Pacing Clin Electrophysiol; 1992 May; 15(5):749-55. PubMed ID: 1382277 [TBL] [Abstract][Full Text] [Related]
26. Long-Term Stability and Clinical Utility of Amplified Atrial Electrograms in a Single-Lead ICD System with Floating Atrial Electrodes. Worden NE; Alqasrawi M; Mazur A Pacing Clin Electrophysiol; 2016 Dec; 39(12):1327-1334. PubMed ID: 27778352 [TBL] [Abstract][Full Text] [Related]
27. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert. Gelder RN; Gunderson BD Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317 [TBL] [Abstract][Full Text] [Related]
28. Variability of atrial sensing during exercise in a patient with a dual chamber ICD caused inappropriate ICD discharges. Glotzer TV; Radoslovich GA; Neglia J; Zimmerman JM Pacing Clin Electrophysiol; 1999 Dec; 22(12):1838-41. PubMed ID: 10642144 [TBL] [Abstract][Full Text] [Related]
29. Inappropriate therapy due to triple counting of the ventricular electrogram in a patient with implantable cardioverter-defibrillator. Alasti M; Haghjoo M; Alizadeh A; Fazelifar AF; Sadr-Ameli MA Heart Rhythm; 2005 Nov; 2(11):1253-5. PubMed ID: 16253917 [No Abstract] [Full Text] [Related]
30. Continuous monitoring of acute myocardial ischemia by the implantable cardioverter defibrillator. Zehender M; Faber T; Grom A; Schwab T; Geibel A; Meinertz T; Just H Am Heart J; 1994 Apr; 127(4 Pt 2):1057-63. PubMed ID: 8160580 [TBL] [Abstract][Full Text] [Related]
31. Inappropriate shocks diagnosed by stored electrograms of implantable cardioverter defibrillators--two case reports. Oto A; Atalar E; Yildirir A; Kabakci G Angiology; 2000 May; 51(5):425-30. PubMed ID: 10826860 [TBL] [Abstract][Full Text] [Related]
32. Multiple appropriate and spurious defibrillator shocks in a patient with right ventricular cardiomyopathy. Strohmer B; Schernthaner C; Pichler M Int J Cardiol; 2005 Jul; 102(2):363-6. PubMed ID: 15982515 [TBL] [Abstract][Full Text] [Related]
33. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms. Kowalski M; Ellenbogen KA; Wood MA; Friedman PL Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976 [TBL] [Abstract][Full Text] [Related]
35. Durability of repaired sensing leads equivalent to that of new leads in implantable cardioverter defibrillator patients with sensing abnormalities. Mahapatra S; Homoud MK; Wang PJ; Estes NA; Link MS Pacing Clin Electrophysiol; 2003 Dec; 26(12):2225-9. PubMed ID: 14675004 [TBL] [Abstract][Full Text] [Related]
36. Failure of third-generation implantable cardioverter defibrillators to abort shock therapy for nonsustained ventricular tachycardia due to shortcomings of the VF confirmation algorithm. Grimm W; Menz V; Hoffmann J; Maisch B Pacing Clin Electrophysiol; 1998 Apr; 21(4 Pt 1):722-7. PubMed ID: 9584303 [TBL] [Abstract][Full Text] [Related]
37. Sensing lead insulation fractures following implantable cardioverter-defibrillator placement. Tedder M; Anstadt MP; Tedder SD; Revishvili AS; Hegde SS; Lowe JE ASAIO J; 1993; 39(3):M711-4. PubMed ID: 8268630 [TBL] [Abstract][Full Text] [Related]
38. [Inadequate therapies with implantable cardioverter-defibrillators--incidence, etiology, predictive factors and preventive strategies]. Weber M; Block M; Brunn J; Bänsch D; Böcker D; Hammel D; Gietzen F; Breithardt G Z Kardiol; 1996 Nov; 85(11):809-19. PubMed ID: 9064943 [TBL] [Abstract][Full Text] [Related]
39. Is inappropriate therapy a resolved issue with current implantable cardioverter defibrillators? Brugada J Am J Cardiol; 1999 Mar; 83(5B):40D-44D. PubMed ID: 10089838 [TBL] [Abstract][Full Text] [Related]
40. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators. Swerdlow CD; Schsls W; Dijkman B; Jung W; Sheth NV; Olson WH; Gunderson BD Circulation; 2000 Feb; 101(8):878-85. PubMed ID: 10694527 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]