These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
225 related articles for article (PubMed ID: 7662379)
21. The Hancock II bioprosthesis at ten years. David TE; Armstrong S; Sun Z Ann Thorac Surg; 1995 Aug; 60(2 Suppl):S229-34. PubMed ID: 7646164 [TBL] [Abstract][Full Text] [Related]
22. Failure of Hancock pericardial xenografts: is prophylactic bioprosthetic replacement justified? Bortolotti U; Milano A; Guerra F; Mazzucco A; Mossuto E; Thiene G; Gallucci V Ann Thorac Surg; 1991 Mar; 51(3):430-7. PubMed ID: 1998420 [TBL] [Abstract][Full Text] [Related]
23. [Influence of the valve position on the complications related to pericardial Carpentier-Edwards valve after 8 years]. Aupart M; Dreyfus X; Meurisse Y; May MA; Sirinelli A; Marchand M Arch Mal Coeur Vaiss; 1995 Jul; 88(7):967-71. PubMed ID: 7487327 [TBL] [Abstract][Full Text] [Related]
24. Durability of pericardial versus porcine aortic valves. Gao G; Wu Y; Grunkemeier GL; Furnary AP; Starr A J Am Coll Cardiol; 2004 Jul; 44(2):384-8. PubMed ID: 15261935 [TBL] [Abstract][Full Text] [Related]
25. The Carpentier-Edwards pericardial bioprosthesis: clinical experience with 600 patients. Pelletier LC; Carrier M; Leclerc Y; Dyrda I Ann Thorac Surg; 1995 Aug; 60(2 Suppl):S297-302. PubMed ID: 7646176 [TBL] [Abstract][Full Text] [Related]
26. Late results of mitral valve replacement with Carpentier-Edwards high profile bioprosthesis in young adults. Yamak B; Sener E; Kiziltepe U; Mavitas B; Tasdemir O; Bayazit K Eur J Cardiothorac Surg; 1995; 9(6):335-41. PubMed ID: 7546808 [TBL] [Abstract][Full Text] [Related]
27. The Carpentier-Edwards supra-annular porcine bioprosthesis: new generation low pressure glutaraldehyde fixed prosthesis. Jamieson WR; Munro AI; Miyagishima RT; Allen P; Janusz MT; Gerein AN; Burr LH; Ling H; Hayden RI; Tutassura H J Card Surg; 1988 Dec; 3(4):507-21. PubMed ID: 2980055 [TBL] [Abstract][Full Text] [Related]
28. Structural valve deterioration in mitral replacement surgery: comparison of Carpentier-Edwards supra-annular porcine and perimount pericardial bioprostheses. Eric Jamieson WR; Marchand MA; Pelletier CL; Norton R; Pellerin M; Dubiel TW; Aupart MR; Daenen WJ; Holden MP; David TE; Ryba EA; Anderson WN J Thorac Cardiovasc Surg; 1999 Aug; 118(2):297-304. PubMed ID: 10425003 [TBL] [Abstract][Full Text] [Related]
29. Porcine cardiac bioprostheses: evaluation of long-term results in 990 patients. Zussa C; Ottino G; di Summa M; Poletti GA; Zattera GF; Pansini S; Morea M Ann Thorac Surg; 1985 Mar; 39(3):243-50. PubMed ID: 3977465 [TBL] [Abstract][Full Text] [Related]
30. The Carpentier-Edwards pericardial aortic valve. Ten-year results. Cosgrove DM; Lytle BW; Taylor PC; Camacho MT; Stewart RW; McCarthy PM; Miller DP; Piedmonte MR; Loop FD J Thorac Cardiovasc Surg; 1995 Sep; 110(3):651-62. PubMed ID: 7564431 [TBL] [Abstract][Full Text] [Related]
31. Influence of age on valve related events with Carpentier-Edwards pericardial bioprosthesis. Aupart M; Babuty D; Neville P; Fauchier L; Sirinelli A; Marchand M Eur J Cardiothorac Surg; 1997 May; 11(5):929-34. PubMed ID: 9196311 [TBL] [Abstract][Full Text] [Related]
32. Experience with low-dose aspirin as thromboprophylaxis for the Tissuemed porcine aortic bioprosthesis: a survey of five years' experience. Goldsmith I; Lip GY; Mukundan S; Rosin MD J Heart Valve Dis; 1998 Sep; 7(5):574-9. PubMed ID: 9793859 [TBL] [Abstract][Full Text] [Related]
33. Seventeen-year experience with the St. Jude medical biocor porcine bioprosthesis. Mykén PS J Heart Valve Dis; 2005 Jul; 14(4):486-92. PubMed ID: 16116875 [TBL] [Abstract][Full Text] [Related]
34. Determinants of 15-year outcome with 1,119 standard Carpentier-Edwards porcine valves. Glower DD; Landolfo KP; Cheruvu S; Cen YY; Harrison JK; Bashore TM; Smith PK; Jones RH; Wolfe WG; Lowe JE Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S44-8. PubMed ID: 9930415 [TBL] [Abstract][Full Text] [Related]
35. Mid-term comparative follow-up after aortic valve replacement with Carpentier-Edwards and Pericarbon pericardial prostheses. Le Tourneau T; Savoye C; McFadden EP; Grandmougin D; Carton HF; Hennequin JL; Dubar A; Fayad G; Warembourg H Circulation; 1999 Nov; 100(19 Suppl):II11-6. PubMed ID: 10567272 [TBL] [Abstract][Full Text] [Related]
36. The Carpentier-Edwards standard porcine bioprosthesis: clinical performance to 15 years. Jamieson WR; Hayden RI; Miyagishima RT; Tutassaura H; Munro AI; Gerein AN; Burr LH; MacNab J; Janusz MT; Chan F J Card Surg; 1991 Dec; 6(4 Suppl):550-6. PubMed ID: 1810545 [TBL] [Abstract][Full Text] [Related]
37. Use of the Carpentier-Edwards porcine bioprosthesis: assessment of a patient selection policy. Louagie Y; Noirhomme P; Aranguis E; Eucher P; Vanruyssevelt P; Buche M; Dion R; Jaumin P; Schoevaerdts JC; Chalant CH J Thorac Cardiovasc Surg; 1992 Oct; 104(4):1013-24. PubMed ID: 1405658 [TBL] [Abstract][Full Text] [Related]
38. The third generation Carpentier-Edwards bioprosthesis: early results. Relland J; Perier P; Lecointe B J Am Coll Cardiol; 1985 Nov; 6(5):1149-54. PubMed ID: 4045039 [TBL] [Abstract][Full Text] [Related]
39. Durability of pericardial versus porcine bioprosthetic heart valves. Grunkemeier GL; Furnary AP; Wu Y; Wang L; Starr A J Thorac Cardiovasc Surg; 2012 Dec; 144(6):1381-6. PubMed ID: 23010581 [TBL] [Abstract][Full Text] [Related]
40. The Mitroflow pericardial bioprosthesis. Comparison of early clinical performance in aortic and mitral positions. Jamieson WR; Pelletier LC; Gerein AN; Pomar J Can J Surg; 1992 Apr; 35(2):159-64. PubMed ID: 1562925 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]