These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

59 related articles for article (PubMed ID: 7664534)

  • 1. Acceptability of capillary blood glucose testing with Companion 2 after intensive individual patient training.
    Kabadi UM; Kabadi M; O'Connell KM
    Diabetes Res; 1994; 26(1):25-32. PubMed ID: 7664534
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Current portable blood sugar analysis equipment--comparison of the MediSense Card, Glucometer Elite, Hypocount Supreme and Omnican Control with the glucose oxidase reference method].
    Weitgasser R; Gappmayer B
    Schweiz Med Wochenschr; 1997 Jan; 127(1-2):12-7. PubMed ID: 9036524
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Investigation on the accuracy of the blood glucose monitoring device Prestige IQ.
    Larbig M; Forst T; Mondok A; Forst S; Pfützner A
    Diabetes Nutr Metab; 2003 Aug; 16(4):257-61. PubMed ID: 14768776
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Clinical evaluation of the blood glucose monitors Accutrend, Companion 2, Glucometer 3 and One Touch II in comparison with the glucose oxidase reference method].
    Weitgasser R; Straberger A; Schnöll F; Sailer S
    Wien Klin Wochenschr; 1994; 106(23):738-41. PubMed ID: 7856178
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of blood glucose meters in a New Zealand diabetes centre.
    Florkowski C; Budgen C; Kendall D; Lunt H; Moore MP
    Ann Clin Biochem; 2009 Jul; 46(Pt 4):302-5. PubMed ID: 19454540
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of One Touch HORIZON--a highly affordable glucose monitor.
    Mohan V; Deepa R; Shefali AK; Poongothai S; Monica M; Karkuzhali K
    J Assoc Physicians India; 2004 Oct; 52():779-82. PubMed ID: 15909854
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of recurrent practice at home on the acceptability of capillary blood glucose readings. Accuracy of self blood glucose testing.
    Kabadi UM; O'Connell KM; Johnson J; Kabadi M
    Diabetes Care; 1994 Oct; 17(10):1110-23. PubMed ID: 7821129
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of blood glucose self monitoring in elderly insulin treated diabetic patients.
    Mühlhauser I; Heinemann L; Karinganamattom J; Schuwirth W; Berger M
    Diabete Metab; 1991; 17(5):476-82. PubMed ID: 1752349
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical evaluation of the eBsensor hand-held blood glucose monitoring system.
    Chen CC; Tai DY; Ho P; Lai YK; Lin JJ; Mao SJ; Lin CC; Hsieh YC; Chiang HC; Dai KS
    Clin Chim Acta; 2007 Feb; 377(1-2):170-3. PubMed ID: 17097079
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy and utility of a 10-test disk blood glucose meter.
    Kendall DM; Kaplan RA; Paulson CF; Parkes JL; Tideman AM
    Diabetes Res Clin Pract; 2005 Jan; 67(1):29-35. PubMed ID: 15620431
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Non-invasive blood glucose monitoring by means of near infrared spectroscopy: investigation of long-term accuracy and stability.
    Sämann A; Fischbacher CH; Jagemann KU; Danzer K; Schüler J; Papenkordt L; Müller UA
    Exp Clin Endocrinol Diabetes; 2000; 108(6):406-13. PubMed ID: 11026754
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical evaluation of a novel test strip technology for blood glucose monitoring: accuracy at hypoglycaemic glucose levels.
    Bellary S; Cameron H; Macleod K; Malecha M; Koria K; Raja P; Cabezudo JD; Ellison J
    Diabetes Res Clin Pract; 2012 Dec; 98(3):430-5. PubMed ID: 23063304
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development and evaluation of a patient-oriented education system for diabetes management.
    Lee TI; Yeh YT; Liu CT; Chen PL
    Int J Med Inform; 2007 Sep; 76(9):655-63. PubMed ID: 16815741
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [ExacTech--a new measuring system for personal control of blood glucose].
    Regal H; Zdolsek I; Bali C; Irsigler K
    Wien Med Wochenschr; 1989 Jul; 139(14):337-9. PubMed ID: 2773491
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Capillary versus venous bedside blood glucose estimations.
    Boyd R; Leigh B; Stuart P
    Emerg Med J; 2005 Mar; 22(3):177-9. PubMed ID: 15735263
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of the EasyTouch blood glucose self-monitoring system: a study of 516 cases.
    Dai KS; Tai DY; Ho P; Chen CC; Peng WC; Chen ST; Hsu CC; Liu YP; Hsieh HC; Yang CC; Tsai MC; Mao SJ
    Clin Chim Acta; 2004 Nov; 349(1-2):135-41. PubMed ID: 15469866
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol.
    Petersen JR; Graves DF; Tacker DH; Okorodudu AO; Mohammad AA; Cardenas VJ
    Clin Chim Acta; 2008 Oct; 396(1-2):10-3. PubMed ID: 18606159
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The clinical performance of the EGV1 self-monitoring blood glucose system.
    Chen CC; Lin JJ; Hung ST; Chun PT; Lai YK
    Clin Chim Acta; 2012 Jul; 413(13-14):1039-44. PubMed ID: 22266375
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Screening for type 2 diabetes mellitus using gingival crevicular blood.
    Khader YS; Al-Zu'bi BN; Judeh A; Rayyan M
    Int J Dent Hyg; 2006 Nov; 4(4):179-82. PubMed ID: 17038055
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wavesense technology glucometer Linus for routine self-monitoring and clinical practice.
    Chlup R; Doubravova B; Peterson K; Zapletalova J; Bartek J
    Acta Diabetol; 2011 Mar; 48(1):35-40. PubMed ID: 20694824
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.