These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

224 related articles for article (PubMed ID: 7667021)

  • 1. Corneal swelling and recovery following wear of thick hydrogel contact lenses in insulin-dependent diabetics.
    Skaff A; Cullen AP; Doughty MJ; Fonn D
    Ophthalmic Physiol Opt; 1995 Jul; 15(4):287-97. PubMed ID: 7667021
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Central corneal thickness and corneal hysteresis during corneal swelling induced by contact lens wear with eye closure.
    Lu F; Xu S; Qu J; Shen M; Wang X; Fang H; Wang J
    Am J Ophthalmol; 2007 Apr; 143(4):616-22. PubMed ID: 17306755
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements.
    Hamilton KE; Pye DC; Hali A; Lin C; Kam P; Ngyuen T
    J Glaucoma; 2007 Jan; 16(1):153-8. PubMed ID: 17224766
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of long-term extended contact lens wear on the human cornea.
    Holden BA; Sweeney DF; Vannas A; Nilsson KT; Efron N
    Invest Ophthalmol Vis Sci; 1985 Nov; 26(11):1489-501. PubMed ID: 3863808
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Corneal function during normal and high serum glucose levels in diabetes.
    McNamara NA; Brand RJ; Polse KA; Bourne WM
    Invest Ophthalmol Vis Sci; 1998 Jan; 39(1):3-17. PubMed ID: 9430539
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of corneal thickness of long-term contact lens wearers for different types of contact lenses.
    Iskeleli G; Onur U; Ustundag C; Ozkan S
    Eye Contact Lens; 2006 Sep; 32(5):219-22. PubMed ID: 16974153
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Regional changes in corneal thickness and shape with soft contact lenses.
    Tyagi G; Collins M; Read S; Davis B
    Optom Vis Sci; 2010 Aug; 87(8):567-75. PubMed ID: 20512082
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of corneal edema on dynamic contour and goldmann tonometry.
    Hamilton KE; Pye DC; Kao L; Pham N; Tran AQ
    Optom Vis Sci; 2008 Jun; 85(6):451-6. PubMed ID: 18521023
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Morphology and function of the corneal endothelium after long-term contact lens wear.
    Nieuwendaal CP; Odenthal MT; Kok JH; Venema HW; Oosting J; Riemslag FC; Kijlstra A
    Invest Ophthalmol Vis Sci; 1994 Jun; 35(7):3071-7. PubMed ID: 8206725
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Central corneal thickness and measured IOP: a clinical study.
    Phillips LJ; Cakanac CJ; Eger MW; Lilly ME
    Optometry; 2003 Apr; 74(4):218-25. PubMed ID: 12703686
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corneal response to rigid and hydrogel lenses during eye closure.
    O'Neal MR; Polse KA; Sarver MD
    Invest Ophthalmol Vis Sci; 1984 Jul; 25(7):837-42. PubMed ID: 6735648
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Objective measurements of corneal light-backscatter during corneal swelling, by optical coherence tomography.
    Wang J; Simpson TL; Fonn D
    Invest Ophthalmol Vis Sci; 2004 Oct; 45(10):3493-8. PubMed ID: 15452054
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Corneal edema recovery dynamics in diabetes: is the alloxan induced diabetic rabbit a useful model?
    Herse P; Hooker B
    Invest Ophthalmol Vis Sci; 1994 Jan; 35(1):310-3. PubMed ID: 8300358
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sympathetic swelling response of the control eye to soft lenses in the other eye.
    Fonn D; du Toit R; Simpson TL; Vega JA; Situ P; Chalmers RL
    Invest Ophthalmol Vis Sci; 1999 Dec; 40(13):3116-21. PubMed ID: 10586932
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Corneal shape changes induced by first and second generation silicone hydrogel contact lenses in daily wear.
    Alba-Bueno F; Beltran-Masgoret A; Sanjuan C; Biarnés M; Marín J
    Cont Lens Anterior Eye; 2009 Apr; 32(2):88-92. PubMed ID: 19181564
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relationship between central corneal thickness and hypotony maculopathy after trabeculectomy.
    Nicolela MT; Carrillo MM; Yan DB; Rafuse PE
    Ophthalmology; 2007 Jul; 114(7):1266-71. PubMed ID: 17316806
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of central corneal thickness on the efficacy of topical ocular hypotensive medications.
    Johnson TV; Toris CB; Fan S; Camras CB
    J Glaucoma; 2008 Mar; 17(2):89-99. PubMed ID: 18344753
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of contact lens induced oedema on the accuracy of Goldmann tonometry in a mature population.
    Hamilton K; Pye D; Hua S; Yu F; Chung J; Hou Q
    Br J Ophthalmol; 2007 Dec; 91(12):1636-8. PubMed ID: 17504854
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of central corneal thickness and corneal curvature radius on the intraocular pressure as measured by different tonometers: noncontact and goldmann applanation tonometers.
    Harada Y; Hirose N; Kubota T; Tawara A
    J Glaucoma; 2008 Dec; 17(8):619-25. PubMed ID: 19092456
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer.
    Kotecha A; Elsheikh A; Roberts CR; Zhu H; Garway-Heath DF
    Invest Ophthalmol Vis Sci; 2006 Dec; 47(12):5337-47. PubMed ID: 17122122
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.