These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 7669323)

  • 1. Severe hypoventilation resulting from improper use of a disposable manual resuscitator.
    Freeman G; Hannallah M
    J Clin Anesth; 1995 May; 7(3):267. PubMed ID: 7669323
    [No Abstract]   [Full Text] [Related]  

  • 2. A comparison of three neonatal resuscitation devices.
    Bennett S; Finer NN; Rich W; Vaucher Y
    Resuscitation; 2005 Oct; 67(1):113-8. PubMed ID: 16081202
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Manual resuscitators and spontaneous ventilation--an evaluation.
    Stemp LI
    Crit Care Med; 1992 Oct; 20(10):1496. PubMed ID: 1395677
    [No Abstract]   [Full Text] [Related]  

  • 4. Human studies may overestimate injuries related to mechanical chest compression cardiopulmonary resuscitation.
    Xanthos T; Pantazopoulos I; Papadimitriou L
    Resuscitation; 2010 Jun; 81(6):775; author reply 775-6. PubMed ID: 20223577
    [No Abstract]   [Full Text] [Related]  

  • 5. Pulmonary exhaled-air resuscitators: manual, reusable; manual, disposable.
    Nobel JJ
    Pediatr Emerg Care; 1994 Feb; 10(1):44-7. PubMed ID: 8177807
    [No Abstract]   [Full Text] [Related]  

  • 6. Benefits of Manometer in Non-Invasive Ventilatory Support.
    Lacerda RS; de Lima FCA; Bastos LP; Fardin Vinco A; Schneider FBA; Luduvico Coelho Y; Fernandes HGC; Bacalhau JMR; Bermudes IMS; da Silva CF; da Silva LP; Pezato R
    Prehosp Disaster Med; 2017 Dec; 32(6):615-620. PubMed ID: 28743318
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of an oxygen-powered flow-limited resuscitator to manual ventilation with an adult 1,000-mL self-inflating bag.
    Barnes TA; Catino ME; Burns EC; Chan WK; Ghazarian G; Henneberg WR; Ruel KE; Stanley SA
    Respir Care; 2005 Nov; 50(11):1445-50. PubMed ID: 16253151
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Extensive soft tissue trauma due to prolonged cardiopulmonary resuscitation using an automated chest compression (ACC) device.
    Michalski T; Gottardi R; Dünser MW
    Emerg Med J; 2014 May; 31(5):431. PubMed ID: 23985340
    [No Abstract]   [Full Text] [Related]  

  • 9. [Comparative study for effects of bare-handed CPR with Thumper cardiopulmonary resuscitator CPR in emergency department based on "the Utstein style"].
    Zhang C; Wang Y; Liu H; Hao A; Xun J; Meng Q
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2017 Oct; 29(10):937-939. PubMed ID: 29017657
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Extensive injury after use of a mechanical cardiopulmonary resuscitation device.
    Wind J; Bekkers SC; van Hooren LJ; van Heurn LW
    Am J Emerg Med; 2009 Oct; 27(8):1017.e1-2. PubMed ID: 19857428
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Don't forget to ventilate during cardiopulmonary resuscitation with mechanical chest compression devices.
    Bernhard M; Hossfeld B; Kumle B; Becker TK; Böttiger B; Birkholz T
    Eur J Anaesthesiol; 2016 Aug; 33(8):553-6. PubMed ID: 26854661
    [No Abstract]   [Full Text] [Related]  

  • 12. Comparison of methods of bag and mask ventilation for neonatal resuscitation.
    Finer NN; Rich W; Craft A; Henderson C
    Resuscitation; 2001 Jun; 49(3):299-305. PubMed ID: 11719125
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lung injuries secondary to mechanical chest compressions.
    Mateos Rodríguez AA; Pascual JM; Vallejo FP; García AP; Belmonte AA
    Resuscitation; 2012 Oct; 83(10):e203. PubMed ID: 22820014
    [No Abstract]   [Full Text] [Related]  

  • 14. Stomach rupture during CPR.
    Liu N; Boyle K; Bertrand C; Bonnet F
    Ann Emerg Med; 1996 Jan; 27(1):105-6. PubMed ID: 8572441
    [No Abstract]   [Full Text] [Related]  

  • 15. Active compression-decompression resuscitation: effect on resuscitation success after in-hospital cardiac arrest.
    Tucker KJ; Galli F; Savitt MA; Kahsai D; Bresnahan L; Redberg RF
    J Am Coll Cardiol; 1994 Jul; 24(1):201-9. PubMed ID: 8006266
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cerebral air embolism caused by cardiopulmonary resuscitation after cardiopulmonary arrest on arrival.
    Hashimoto Y; Yamaki T; Sakakibara T; Matsui J; Matsui M
    J Trauma; 2000 May; 48(5):975-7. PubMed ID: 10823549
    [No Abstract]   [Full Text] [Related]  

  • 17. Fatal complication secondary to mechanical chest compression device.
    de Rooij PP; Wiendels DR; Snellen JP
    Resuscitation; 2009 Oct; 80(10):1214-5. PubMed ID: 19581042
    [No Abstract]   [Full Text] [Related]  

  • 18. A comparison of standard and a modified method of two resuscitator adult cardiopulmonary resuscitation: description of a new system for research into advanced life support skills.
    Dunkley CJ; Thomas AN; Taylor RJ; Perkins RJ
    Resuscitation; 1998 Jul; 38(1):7-12. PubMed ID: 9783503
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of 16 adult disposable manual resuscitators.
    Mazzolini DG; Marshall NA
    Respir Care; 2004 Dec; 49(12):1509-14. PubMed ID: 15571642
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Phased chest and abdominal compression-decompression. A new option for cardiopulmonary resuscitation.
    Tang W; Weil MH; Schock RB; Sato Y; Lucas J; Sun S; Bisera J
    Circulation; 1997 Mar; 95(5):1335-40. PubMed ID: 9054868
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.