These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 7671497)

  • 1. Titanium nitride ceramic film against polyethylene. A 48 million cycle wear test.
    Pappas MJ; Makris G; Buechel FF
    Clin Orthop Relat Res; 1995 Aug; (317):64-70. PubMed ID: 7671497
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.
    Davidson JA
    Clin Orthop Relat Res; 1993 Sep; (294):361-78. PubMed ID: 8358943
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement.
    Lancaster JG; Dowson D; Isaac GH; Fisher J
    Proc Inst Mech Eng H; 1997; 211(1):17-24. PubMed ID: 9141887
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements.
    Semlitsch M; Willert HG
    Proc Inst Mech Eng H; 1997; 211(1):73-88. PubMed ID: 9141893
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head.
    Minakawa H; Stone MH; Wroblewski BM; Lancaster JG; Ingham E; Fisher J
    J Bone Joint Surg Br; 1998 Sep; 80(5):894-9. PubMed ID: 9768905
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis.
    Meftah M; Klingenstein GG; Yun RJ; Ranawat AS; Ranawat CS
    J Bone Joint Surg Am; 2013 Jul; 95(13):1193-7. PubMed ID: 23824387
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening device.
    McKellop H; Clarke I; Markolf K; Amstutz H
    J Biomed Mater Res; 1981 Sep; 15(5):619-53. PubMed ID: 12659132
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Articular surface material effect on metal-backed patellar components. A microscopic evaluation.
    Milliano MT; Whiteside LA
    Clin Orthop Relat Res; 1991 Dec; (273):204-14. PubMed ID: 1959273
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads.
    Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2008 Oct; 222(7):1073-80. PubMed ID: 19024155
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A comparative study of the characteristics of femoral hip prosthesis heads--study and results ceramic-coated hip joint heads of titanium].
    Hennig FF; von Kroge H; Repenning D
    Biomed Tech (Berl); 1992 Sep; 37(9):200-4. PubMed ID: 1391607
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the effect of the femoral articular surface material on the wear of a metal-backed patellar component.
    Milliano MT; Whiteside LA; Kaiser AD; Zwirkoski PA
    Clin Orthop Relat Res; 1993 Feb; (287):178-86. PubMed ID: 8448938
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultra-high-molecular weight polyethylene wear: an in vitro comparison of acetabular metal types and polished surfaces.
    Shepard MF; Lieberman JR; Kabo JM
    J Arthroplasty; 1999 Oct; 14(7):860-6. PubMed ID: 10537263
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.
    Al-Hajjar M; Fisher J; Tipper JL; Williams S; Jennings LM
    Proc Inst Mech Eng H; 2013 May; 227(5):535-42. PubMed ID: 23637263
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Serum-cobalt levels with metal-on-metal bearings in the cement-free total hip arthroplasty results covering two years; prospective study.
    Weissinger M; Grübl A; Pöll G
    Acta Chir Orthop Traumatol Cech; 2011; 78(5):410-5. PubMed ID: 22094154
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [In-vivo wear of the slide combinations ceramics-polyethylene as opposed to metal-polyethylene].
    Zichner L; Lindenfeld T
    Orthopade; 1997 Feb; 26(2):129-34. PubMed ID: 9157352
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.
    Davidson JA; Poggie RA; Mishra AK
    Biomed Mater Eng; 1994; 4(3):213-29. PubMed ID: 7950870
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study.
    Kim YH
    J Bone Joint Surg Am; 2005 Aug; 87(8):1769-76. PubMed ID: 16085617
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator.
    Saikko VO; Paavolainen PO; Slätis P
    Acta Orthop Scand; 1993 Aug; 64(4):391-402. PubMed ID: 8213114
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transfer of metallic debris after dislocation of ceramic femoral heads in hip prostheses.
    Müller FA; Hagymási M; Greil P; Zeiler G; Schuh A
    Arch Orthop Trauma Surg; 2006 Apr; 126(3):174-80. PubMed ID: 16482451
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femoral head technologies to reduce polyethylene wear in total hip arthroplasty.
    Cuckler JM; Bearcroft J; Asgian CM
    Clin Orthop Relat Res; 1995 Aug; (317):57-63. PubMed ID: 7671496
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.