These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 7671534)

  • 1. Emergent treatment of pelvic fractures. Comparison of methods for stabilization.
    Ghanayem AJ; Stover MD; Goldstein JA; Bellon E; Wilber JH
    Clin Orthop Relat Res; 1995 Sep; (318):75-80. PubMed ID: 7671534
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [A simple supraacetabular external fixation for pelvic ring fractures].
    Gänsslen A; Pohlemann T; Krettek C
    Oper Orthop Traumatol; 2005 Sep; 17(3):296-312. PubMed ID: 16132252
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Control of severe hemorrhage using C-clamp and arterial embolization in hemodynamically unstable patients with pelvic ring disruption.
    Sadri H; Nguyen-Tang T; Stern R; Hoffmeyer P; Peter R
    Arch Orthop Trauma Surg; 2005 Sep; 125(7):443-7. PubMed ID: 15977021
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The antishock pelvic clamp.
    Ganz R; Krushell RJ; Jakob RP; Küffer J
    Clin Orthop Relat Res; 1991 Jun; (267):71-8. PubMed ID: 2044295
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Treatment of old Tile B1 pelvic fracture by staged pelvic closure using external fixator combined with reconstruction plate].
    Tian Y; Fu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Mar; 22(3):324-7. PubMed ID: 18396713
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The antishock iliosacral screw.
    Gardner MJ; Chip Routt ML
    J Orthop Trauma; 2010 Oct; 24(10):e86-9. PubMed ID: 20871242
    [TBL] [Abstract][Full Text] [Related]  

  • 7. External fixation of the pelvic ring: an experimental study on the role of pin diameter, pin position, and parasymphyseal fixator pins.
    Ponsen KJ; Joosse P; Van Dijke GA; Snijders CJ
    Acta Orthop; 2007 Oct; 78(5):648-53. PubMed ID: 17966024
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Distraction external fixation in lateral compression pelvic fractures.
    Bellabarba C; Ricci WM; Bolhofner BR
    J Orthop Trauma; 2006 Jan; 20(1 Suppl):S7-14. PubMed ID: 16385210
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Skeletal deformity after anterior external fixation of the pelvis.
    Dickson KF; Matta JM
    J Orthop Trauma; 2009; 23(5):327-32. PubMed ID: 19390359
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Biomechanical comparison of various emergency stabilization measures of the pelvic ring].
    Pohlemann T; Krettek C; Hoffmann R; Culemann U; Gänsslen A
    Unfallchirurg; 1994 Oct; 97(10):503-10. PubMed ID: 7809636
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The immediate treatment of pelvic ring disruption with the pelvic stabilizer.
    Ward LD; Morandi MM; Pearse M; Randelli P; Landi S
    Bull Hosp Jt Dis; 1997; 56(2):104-6. PubMed ID: 9220102
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stabilization of unstable pelvic fractures with a novel internal-external fixator.
    Jiang ZL; Chen G
    Chin Med J (Engl); 2011 Dec; 124(23):4112-4. PubMed ID: 22340356
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of laparotomy and external fixator stabilization on pelvic volume in an unstable pelvic injury.
    Ghanayem AJ; Wilber JH; Lieberman JM; Motta AO
    J Trauma; 1995 Mar; 38(3):396-400; discussion 400-1. PubMed ID: 7897726
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of fixation methods for preventing pelvic ring expansion.
    Vrahas MS; Wilson SC; Cummings PD; Paul EM
    Orthopedics; 1998 Mar; 21(3):285-9. PubMed ID: 9547813
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preperitonal pelvic packing for hemodynamically unstable pelvic fractures: a paradigm shift.
    Cothren CC; Osborn PM; Moore EE; Morgan SJ; Johnson JL; Smith WR
    J Trauma; 2007 Apr; 62(4):834-9; discussion 839-42. PubMed ID: 17426537
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Percutaneous pelvic fixation using working portals in a circumferential pelvic antishock sheet.
    Gardner MJ; Osgood G; Molnar R; Chip Routt ML
    J Orthop Trauma; 2009 Oct; 23(9):668-74. PubMed ID: 19897990
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of external fixation versus the trauma pelvic orthotic device on unstable pelvic injuries: a cadaveric study of stability.
    Prasarn ML; Horodyski M; Conrad B; Rubery PT; Dubose D; Small J; Rechtine GR
    J Trauma Acute Care Surg; 2012 Jun; 72(6):1671-5. PubMed ID: 22695439
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A protocol for the initial management of unstable pelvic fractures.
    Bassam D; Cephas GA; Ferguson KA; Beard LN; Young JS
    Am Surg; 1998 Sep; 64(9):862-7. PubMed ID: 9731815
    [TBL] [Abstract][Full Text] [Related]  

  • 19. External fixation in pelvic fractures.
    Scaglione M; Parchi P; Digrandi G; Latessa M; Guido G
    Musculoskelet Surg; 2010 Nov; 94(2):63-70. PubMed ID: 21086087
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Initial experience with the T-Clamp for temporary fixation of mechanically and hemodynamically unstable pelvic ring injuries.
    Sepehri A; Sciadini MF; Nascone JW; Manson TT; O'Toole RV; Slobogean GP
    Injury; 2020 Mar; 51(3):699-704. PubMed ID: 32037004
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.