BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

62 related articles for article (PubMed ID: 7671705)

  • 1. [Tissue morphology at the site of fusion after osteotomy of the proximal end of the femur in children].
    Wasilewski K; Król R; Pankowski J
    Chir Narzadow Ruchu Ortop Pol; 1993; 58(4):267-71. PubMed ID: 7671705
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Effect of osteotomy metal plate anastomosis with the femur on stimulation of lower femur growth in children].
    Wasilewski K
    Ann Acad Med Stetin; 2001; 47():189-205. PubMed ID: 12514910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Deep, late infections associated with internal fixation in children.
    Highland TR; LaMont RL
    J Pediatr Orthop; 1985; 5(1):59-64. PubMed ID: 3980708
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Measurement of the electric potential difference between the plate and the bone and its impact on elongation of the limb after corrective osteotomy of the proximal end of the femur in children].
    Wasilewski K; Lach W
    Chir Narzadow Ruchu Ortop Pol; 1997; 62(5):427-30. PubMed ID: 9490258
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Which implant for proximal femoral osteotomy in children? A comparison of the AO (ASIF) 90 degree fixed-angle blade plate and the Richards intermediate hip screw.
    Hau R; Dickens DR; Nattrass GR; O'Sullivan M; Torode IP; Graham HK
    J Pediatr Orthop; 2000; 20(3):336-43. PubMed ID: 10823601
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Proximal femoral osteotomy using the AO fixed-angle blade plate.
    Beauchesne R; Miller F; Moseley C
    J Pediatr Orthop; 1992; 12(6):735-40. PubMed ID: 1452742
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technical problems and complications in the removal of the less invasive stabilization system.
    Suzuki T; Smith WR; Stahel PF; Morgan SJ; Baron AJ; Hak DJ
    J Orthop Trauma; 2010 Jun; 24(6):369-73. PubMed ID: 20502220
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Histologic analysis of distraction osteogenesis in the femoral shaft of the immature rabbit.
    Moro Robledo J; de la Varga Salto V; Guerado Parra E; De Santos de la Fuente J; Lopez Arevalo R; Espejo Baena A
    Acta Orthop Belg; 1998 Jun; 64(2):125-30. PubMed ID: 9689750
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Ostoesynthesis using screw-plates in the intertrochanteric region, in the child].
    Rigault P
    Nouv Presse Med; 1975 Mar; 4(13):961-3. PubMed ID: 1144037
    [No Abstract]   [Full Text] [Related]  

  • 10. [Hip surgery: local tissue reactions].
    Forest M; Courpied JP; Lefloch P; Carlioz A; Abelanet R; Postel M
    Ann Pathol; 1985; 5(1):3-18. PubMed ID: 3893449
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The callotasis method of limb lengthening.
    Aldegheri R; Renzi-Brivio L; Agostini S
    Clin Orthop Relat Res; 1989 Apr; (241):137-45. PubMed ID: 2924457
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Corrosion of metal implants--causes of unsuccessful surgical treatment of injuries of the osteoarticular system].
    Horský I
    Bratisl Lek Listy; 1984 Nov; 82(5):1351-5. PubMed ID: 6509335
    [No Abstract]   [Full Text] [Related]  

  • 13. Cannulated blade plate for proximal femoral varus osteotomy.
    Grant AD; Lehman WB; Strongwater AM; Atar D
    Clin Orthop Relat Res; 1990 Oct; (259):111-3. PubMed ID: 2208844
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [AOI compression plate for intertrochantic osteotomy of the femur].
    Yamada K; Suzuki K; Kobayashi A; Takarazumi Y; Okuyama S
    Shujutsu; 1971 Dec; 25(12):1431-40. PubMed ID: 5146377
    [No Abstract]   [Full Text] [Related]  

  • 15. [The assessment of changes of the plate growth in Blount disease by MRI].
    Synder M; Grzegorzewski A; Marciniak M
    Chir Narzadow Ruchu Ortop Pol; 1998; 63(5):437-41. PubMed ID: 10093387
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pseudoaneurysm secondary to a protruding screw as a result of normal growth and remodeling following supracondylar osteotomy. A case report.
    Falconer DP; Adar U
    J Bone Joint Surg Am; 1984 Sep; 66(7):1126-8. PubMed ID: 6480646
    [No Abstract]   [Full Text] [Related]  

  • 17. Stress shielding reduced by a silicon plate-bone interface. A canine experiment.
    Korvick DL; Newbrey JW; Bagby GW; Pettit GD; Lincoln JD
    Acta Orthop Scand; 1989 Oct; 60(5):611-6. PubMed ID: 2557719
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Distal femoral osteotomy using the LCP pediatric condylar 90-degree plate in patients with neuromuscular disorders.
    Rutz E; Gaston MS; Camathias C; Brunner R
    J Pediatr Orthop; 2012; 32(3):295-300. PubMed ID: 22411337
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Cranial and cranio-facial osteotomies: containing with miniature screw plates].
    Buchheit F; Maitrot D; Lodde JP; Thiebaut JB; Champy M
    Rev Otoneuroophtalmol; 1978; 50(3):301-4. PubMed ID: 694312
    [No Abstract]   [Full Text] [Related]  

  • 20. [Hyperplastic callusformation in osteogenesis imperfecta (author's transl)].
    Krepler R; Zhuber K
    Z Orthop Ihre Grenzgeb; 1974 Apr; 112(2):306-13. PubMed ID: 4276740
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.