BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

449 related articles for article (PubMed ID: 7681875)

  • 1. Saturation by pulse oximetry: comparison of the results obtained by instruments of different brands.
    Thilo EH; Andersen D; Wasserstein ML; Schmidt J; Luckey D
    J Pediatr; 1993 Apr; 122(4):620-6. PubMed ID: 7681875
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation.
    Carter BG; Carlin JB; Tibballs J; Mead H; Hochmann M; Osborne A
    Crit Care Med; 1998 Jun; 26(6):1128-33. PubMed ID: 9635666
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of recorded values from six pulse oximeters.
    Choe H; Tashiro C; Fukumitsu K; Yagi M; Yoshiya I
    Crit Care Med; 1989 Jul; 17(7):678-81. PubMed ID: 2736930
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry.
    Barker SJ; Tremper KK; Hyatt J
    Anesthesiology; 1989 Jan; 70(1):112-7. PubMed ID: 2912291
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of fetal haemoglobin on the accuracy of pulse oximetry in preterm infants.
    Rajadurai VS; Walker AM; Yu VY; Oates A
    J Paediatr Child Health; 1992 Feb; 28(1):43-6. PubMed ID: 1372809
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reliability of six pulse oximeters in chronic obstructive pulmonary disease.
    Hannhart B; Michalski H; Delorme N; Chapparo G; Polu JM
    Chest; 1991 Apr; 99(4):842-6. PubMed ID: 2009785
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulse oximetry fails to accurately detect low levels of arterial hemoglobin oxygen saturation in dogs.
    Sidi A; Rush W; Gravenstein N; Ruiz B; Paulus DA; Davis RF
    J Clin Monit; 1987 Oct; 3(4):257-62. PubMed ID: 3681359
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Estimation of PaO2 using pulsatile oximetry and the HbO2 dissociation curve in the premature infant].
    Major D; Masson M
    Union Med Can; 1989; 118(1):18, 21-2. PubMed ID: 2711532
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of pulse oximetry to estimate HbO2 fraction of total Hb during exercise.
    Powers SK; Dodd S; Freeman J; Ayers GD; Samson H; McKnight T
    J Appl Physiol (1985); 1989 Jul; 67(1):300-4. PubMed ID: 2759956
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy and precision of fourteen pulse oximeters.
    Hannhart B; Haberer JP; Saunier C; Laxenaire MC
    Eur Respir J; 1991 Jan; 4(1):115-9. PubMed ID: 2026231
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neonatal pulse oximetry: accuracy and reliability.
    Hay WW; Brockway JM; Eyzaguirre M
    Pediatrics; 1989 May; 83(5):717-22. PubMed ID: 2717288
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of skin pigmentation on pulse oximeter accuracy at low saturation.
    Bickler PE; Feiner JR; Severinghaus JW
    Anesthesiology; 2005 Apr; 102(4):715-9. PubMed ID: 15791098
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous comparison of three noninvasive oximeters in healthy volunteers.
    Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
    Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pulse oximetry versus measured arterial oxygen saturation: a comparison of the Nellcor N100 and the Biox III.
    Lebecque P; Shango P; Stijns M; Vliers A; Coates AL
    Pediatr Pulmonol; 1991; 10(2):132-5. PubMed ID: 2030922
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transmission pulse oximetry in the fetal lamb: is there a universal calibration?
    Nijland R; Jongsma HW; Crevels J; Menssen JJ; Nijhuis JG; Oeseburg B
    Pediatr Res; 1996 Mar; 39(3):464-9. PubMed ID: 8929867
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An evaluation of pulse oximetry in prehospital care.
    Aughey K; Hess D; Eitel D; Bleecher K; Cooley M; Ogden C; Sabulsky N
    Ann Emerg Med; 1991 Aug; 20(8):887-91. PubMed ID: 1854074
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of pulse oximetry in the prevention of hyperoxaemia in preterm infants.
    Cochran DP; Shaw NJ
    Eur J Pediatr; 1995 Mar; 154(3):222-4. PubMed ID: 7758522
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of pulse oximetry during hypoxemia.
    Thrush D; Hodges MR
    South Med J; 1994 Apr; 87(4):518-21. PubMed ID: 8153783
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Methodologic problems encountered with cooximetry in methemoglobinemia.
    Rausch-Madison S; Mohsenifar Z
    Am J Med Sci; 1997 Sep; 314(3):203-6. PubMed ID: 9298047
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.