These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 7697277)

  • 1. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia.
    Dreyfuss D; Djedaïni K; Gros I; Mier L; Le Bourdellés G; Cohen Y; Estagnasié P; Coste F; Boussougant Y
    Am J Respir Crit Care Med; 1995 Apr; 151(4):986-92. PubMed ID: 7697277
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia.
    Djedaini K; Billiard M; Mier L; Le Bourdelles G; Brun P; Markowicz P; Estagnasie P; Coste F; Boussougant Y; Dreyfuss D
    Am J Respir Crit Care Med; 1995 Nov; 152(5 Pt 1):1562-9. PubMed ID: 7582295
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change.
    Dreyfuss D; Djedaini K; Weber P; Brun P; Lanore JJ; Rahmani J; Boussougant Y; Coste F
    Am Rev Respir Dis; 1991 Apr; 143(4 Pt 1):738-43. PubMed ID: 2008985
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion.
    Kirton OC; DeHaven B; Morgan J; Morejon O; Civetta J
    Chest; 1997 Oct; 112(4):1055-9. PubMed ID: 9377917
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
    Thomachot L; Vialet R; Arnaud S; Barberon B; Michel-Nguyen A; Martin C
    Crit Care Med; 1999 May; 27(5):923-8. PubMed ID: 10362414
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia.
    Thomachot L; Viviand X; Arnaud S; Boisson C; Martin CD
    Chest; 1998 Nov; 114(5):1383-9. PubMed ID: 9824019
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia.
    Davis K; Evans SL; Campbell RS; Johannigman JA; Luchette FA; Porembka DT; Branson RD
    Crit Care Med; 2000 May; 28(5):1412-8. PubMed ID: 10834688
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of humidification systems on ventilator-associated pneumonia: a randomized multicenter trial.
    Lacherade JC; Auburtin M; Cerf C; Van de Louw A; Soufir L; Rebufat Y; Rezaiguia S; Ricard JD; Lellouche F; Brun-Buisson C; Brochard L
    Am J Respir Crit Care Med; 2005 Nov; 172(10):1276-82. PubMed ID: 16126933
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients.
    Boots RJ; Howe S; George N; Harris FM; Faoagali J
    Crit Care Med; 1997 Oct; 25(10):1707-12. PubMed ID: 9377886
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Humidification method that decreases condensate contamination in ventilator tubing.
    Austan F; Suzukawa M
    Heart Lung; 2000; 29(1):56-9. PubMed ID: 10636958
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical ventilation with or without 7-day circuit changes. A randomized controlled trial.
    Kollef MH; Shapiro SD; Fraser VJ; Silver P; Murphy DM; Trovillion E; Hearns ML; Richards RD; Cracchilo L; Hossin L
    Ann Intern Med; 1995 Aug; 123(3):168-74. PubMed ID: 7598297
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
    Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation.
    Boisson C; Viviand X; Arnaud S; Thomachot L; Miliani Y; Martin C
    Intensive Care Med; 1999 Nov; 25(11):1237-43. PubMed ID: 10654207
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia.
    Memish ZA; Oni GA; Djazmati W; Cunningham G; Mah MW
    Am J Infect Control; 2001 Oct; 29(5):301-5. PubMed ID: 11584255
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia.
    Boots RJ; George N; Faoagali JL; Druery J; Dean K; Heller RF
    Crit Care Med; 2006 Mar; 34(3):687-93. PubMed ID: 16505654
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ventilator-associated pneumonia using a heated humidifier or a heat and moisture exchanger: a randomized controlled trial [ISRCTN88724583].
    Lorente L; Lecuona M; Jiménez A; Mora ML; Sierra A
    Crit Care; 2006; 10(4):R116. PubMed ID: 16884530
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ventilator-associated pneumonia and frequency of circuit changes.
    Stamm AM
    Am J Infect Control; 1998 Feb; 26(1):71-3. PubMed ID: 9503116
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Shivering and rewarming after cardiac surgery: comparison of ventilator circuits with humidifier and heated wires to heat and moisture exchangers.
    McEvoy MT; Carey TJ
    Am J Crit Care; 1995 Jul; 4(4):293-9. PubMed ID: 7663593
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit.
    Kotilainen HR; Keroack MA
    Am J Infect Control; 1997 Apr; 25(2):117-20. PubMed ID: 9113288
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients.
    Kollef MH; Shapiro SD; Boyd V; Silver P; Von Harz B; Trovillion E; Prentice D
    Chest; 1998 Mar; 113(3):759-67. PubMed ID: 9515854
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.