These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 7697898)

  • 21. An accurate amperometric glucose sensor based glucometer with eliminated cross-sensitivity.
    Bani Amer MM
    J Med Eng Technol; 2002; 26(5):208-13. PubMed ID: 12487712
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [New devices for the measurement of blood glucose. Glucometer and Hypocount A].
    Birch K; Sestoft L
    Ugeskr Laeger; 1981 Jul; 143(31):1967-8. PubMed ID: 7303218
    [No Abstract]   [Full Text] [Related]  

  • 23. [New: glucometer. Uninterrupted determination of blood glucose in an instant].
    Pöge AW; Kothe W; Scheller F
    Zentralbl Chir; 1982; 107(17):1128-9. PubMed ID: 7164626
    [No Abstract]   [Full Text] [Related]  

  • 24. Toxic levels of acetaminophen produce a major positive interference on Glucometer Elite and Accu-chek Advantage glucose meters.
    Cartier LJ; Leclerc P; Pouliot M; Nadeau L; Turcotte G; Fruteau-de-Laclos B
    Clin Chem; 1998 Apr; 44(4):893-4. PubMed ID: 9554511
    [No Abstract]   [Full Text] [Related]  

  • 25. Trueness assessment of Korean nation-wide glucose proficiency testing.
    Lee W; Chung HJ; Hannestad U; Kim S; Chun S; Park JY; Song J; Kim JQ; Min WK
    Clin Chem Lab Med; 2011 Jun; 49(6):1061-4. PubMed ID: 21428853
    [No Abstract]   [Full Text] [Related]  

  • 26. Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters.
    Karon BS; Griesmann L; Scott R; Bryant SC; Dubois JA; Shirey TL; Presti S; Santrach PJ
    Diabetes Technol Ther; 2008 Apr; 10(2):111-20. PubMed ID: 18260774
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Evaluation of GLUCOCARD X-METER glucose monitoring system].
    Kwon MJ; Lee SY
    Korean J Lab Med; 2008 Feb; 28(1):8-15. PubMed ID: 18309250
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Quality control of capillary blood measurements in clinical services: follow up by the biologist].
    Desjobert H; Durand G; Chérubin N; Le Moël G
    Diabetes Metab; 2001 Apr; 27(2 Pt 1):177-81. PubMed ID: 11353886
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction.
    Rao LV; Jakubiak F; Sidwell JS; Winkelman JW; Snyder ML
    Clin Chim Acta; 2005 Jun; 356(1-2):178-83. PubMed ID: 15936315
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers.
    Mann EA; Salinas J; Pidcoke HF; Wolf SE; Holcomb JB; Wade CE
    J Trauma; 2008 Jan; 64(1):15-20; discussion 20-1. PubMed ID: 18188093
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hematocrit causes the most significant error in point of care glucometers.
    Mann EA; Pidcoke HF; Salinas J; Wolf SE; Wade CE; Holcomb JB
    Crit Care Med; 2009 Apr; 37(4):1530; author reply 1530-1. PubMed ID: 19318857
    [No Abstract]   [Full Text] [Related]  

  • 32. Clinical utility of a glucose reflectance meter for screening neonates for hypoglycemia.
    Garland J; Alex C; Gleisberg D; Havens P
    J Perinatol; 1996; 16(4):250-3; quiz 254-5. PubMed ID: 8866292
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of a veterinary glucometer for use in horses.
    Hackett ES; McCue PM
    J Vet Intern Med; 2010; 24(3):617-21. PubMed ID: 20337908
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of the Olympus AU 400 clinical chemistry analyzer.
    Bilić A; Alpeza I; Rukavina AS
    Clin Lab; 2000; 46(1-2):1-6. PubMed ID: 10745974
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Assessing portable blood glucose meters for clinical use in cats in the United Kingdom.
    Dobromylskyj MJ; Sparkes AH
    Vet Rec; 2010 Sep; 167(12):438-42. PubMed ID: 20852246
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [A simple instruments for blood glucose measurement].
    Daae L; Ruud T; Ommundsen AK; Sandberg S
    Tidsskr Nor Laegeforen; 1994 Aug; 114(19):2297. PubMed ID: 7992301
    [No Abstract]   [Full Text] [Related]  

  • 37. Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle.
    Megahed AA; Hiew MW; Townsend JR; Messick JB; Constable PD
    J Vet Intern Med; 2015; 29(6):1718-27. PubMed ID: 26486807
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Laboratory assessment of three glucometers.
    Ajala MO; Oladipo OO; Fasanmade O; Adewole TA
    Afr J Med Med Sci; 2003 Sep; 32(3):279-82. PubMed ID: 15030088
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of the APEC analyzer for whole blood glucose. Testing in a pediatric setting.
    Harris NS; Chmil ME; Law T; Rifai N
    Am J Clin Pathol; 1995 Oct; 104(4):477-9. PubMed ID: 7572802
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [An electrochemical instrument ineffective for capillary blood glucose determination].
    Falkensson M; von Schenck H
    Lakartidningen; 1990 Sep; 87(36):2743-5. PubMed ID: 2214985
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.