These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
112 related articles for article (PubMed ID: 7698038)
1. Clinical utility of beta-hydroxybutyrate determined by reflectance meter in the management of diabetic ketoacidosis. Umpierrez GE; Watts NB; Phillips LS Diabetes Care; 1995 Jan; 18(1):137-8. PubMed ID: 7698038 [No Abstract] [Full Text] [Related]
2. Beta-hydroxybutyrate and acetoacetate levels. Foreback CC Am J Clin Pathol; 1997 Nov; 108(5):602-4. PubMed ID: 9353103 [No Abstract] [Full Text] [Related]
3. Bedside blood ketone body monitoring. McBride MO; Smye M; Nesbitt GS; Hadden DR Diabet Med; 1991; 8(7):688-90. PubMed ID: 1833124 [TBL] [Abstract][Full Text] [Related]
4. Laboratory and clinical evaluation of assays for beta-hydroxybutyrate. Porter WH; Yao HH; Karounos DG Am J Clin Pathol; 1997 Mar; 107(3):353-8. PubMed ID: 9052387 [TBL] [Abstract][Full Text] [Related]
5. Monitoring therapy with insulin in ketoacidotic patients by quantifying 3-hydroxybutyrate with a commercial kit. Mercer DW; Losos FJ; Mason L; Kessler GF Clin Chem; 1986 Jan; 32(1 Pt 1):224-5. PubMed ID: 3079681 [No Abstract] [Full Text] [Related]
6. Capillary versus Serum b-hydroxybutyrate in Pediatric Diabetic Ketoacidosis. Kurup PM; Rameshkumar R; Soundravally R; Satheesh P Indian Pediatr; 2019 Feb; 56(2):126-129. PubMed ID: 30819992 [TBL] [Abstract][Full Text] [Related]
8. Treatment of diabetic ketoacidosis using normalization of blood 3-hydroxybutyrate concentration as the endpoint of emergency management. A randomized controlled study. Wiggam MI; O'Kane MJ; Harper R; Atkinson AB; Hadden DR; Trimble ER; Bell PM Diabetes Care; 1997 Sep; 20(9):1347-52. PubMed ID: 9283776 [TBL] [Abstract][Full Text] [Related]
9. Can beta-hydroxybutyrate be detected at the bedside by in vitro oxidation with hydrogen peroxide. Oster JR; Rietberg B; Taylor AL; Perez GO; Chandra R; Gardner LB Diabetes Care; 1984; 7(1):80-2. PubMed ID: 6423353 [TBL] [Abstract][Full Text] [Related]
10. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients. Yu HY; Agus M; Kellogg MD Pediatr Diabetes; 2011 Nov; 12(7):649-55. PubMed ID: 22034832 [TBL] [Abstract][Full Text] [Related]
11. Increased serum D-lactate associated with diabetic ketoacidosis. Christopher MM; Broussard JD; Fallin CW; Drost NJ; Peterson ME Metabolism; 1995 Mar; 44(3):287-90. PubMed ID: 7885271 [TBL] [Abstract][Full Text] [Related]
12. Cost effectiveness of the direct measurement of 3-beta-hydroxybutyrate in the management of diabetic ketoacidosis in children. Vanelli M; Chiari G; Capuano C Diabetes Care; 2003 Mar; 26(3):959. PubMed ID: 12610078 [No Abstract] [Full Text] [Related]
13. [Micromethod for the enzymatic determination of acetoacetic acid and D-(-)-beta-hydroxybutyric acid in blood and tissues]. Stein G; Bässler KH Z Klin Chem Klin Biochem; 1968 Jan; 6(1):27-30. PubMed ID: 4303389 [No Abstract] [Full Text] [Related]
14. Point-of-care β-hydroxybutyrate measurement for the diagnosis of feline diabetic ketoacidaemia. Zeugswetter FK; Rebuzzi L J Small Anim Pract; 2012 Jun; 53(6):328-31. PubMed ID: 22533366 [TBL] [Abstract][Full Text] [Related]
15. Point-of-care beta-hydroxybutyrate testing for assessing diabetic ketoacidosis severity prior to treatment in the emergency department. Arora S; Probst MA; Agy C; Menchine M Diabetes Res Clin Pract; 2011 Dec; 94(3):e86-8. PubMed ID: 21955959 [TBL] [Abstract][Full Text] [Related]
16. Guidelines for management of diabetic ketoacidosis: time to revise? Dhatariya KK; Umpierrez GE Lancet Diabetes Endocrinol; 2017 May; 5(5):321-323. PubMed ID: 28372975 [No Abstract] [Full Text] [Related]
17. Utility of ketone measurement in the prevention, diagnosis and management of diabetic ketoacidosis. Misra S; Oliver NS Diabet Med; 2015 Jan; 32(1):14-23. PubMed ID: 25307274 [TBL] [Abstract][Full Text] [Related]
18. Fully automated assay of blood D-3-hydroxybutyrate for ketosis. Hsu WS; Kao JT; Tsai KS J Formos Med Assoc; 1993 Apr; 92(4):336-40. PubMed ID: 8104581 [TBL] [Abstract][Full Text] [Related]
19. Accuracy of serum beta-hydroxybutyrate measurements for the diagnosis of diabetic ketoacidosis in 116 dogs. Duarte R; Simoes DM; Franchini ML; Marquezi ML; Ikesaki JH; Kogika MM J Vet Intern Med; 2002; 16(4):411-7. PubMed ID: 12141302 [TBL] [Abstract][Full Text] [Related]