These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. MSE behavior of biomedical event-related filters. Barros AK; Ohnishi N IEEE Trans Biomed Eng; 1997 Sep; 44(9):848-55. PubMed ID: 9282477 [TBL] [Abstract][Full Text] [Related]
4. [The application of adaptive algorithm and wavelet transform in the filtering of ECG signal]. Zhang J; Zhang G; Dai G Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Oct; 23(5):977-80. PubMed ID: 17121335 [TBL] [Abstract][Full Text] [Related]
5. A new ensemble averaging technique in impedance cardiography for estimation of stroke volume during treadmill exercise. Kim DW; Song CG; Lee MH Front Med Biol Eng; 1992; 4(3):179-88. PubMed ID: 1419917 [TBL] [Abstract][Full Text] [Related]
6. Impedance cardiography filtering using scale Fourier linear combiner based on RLS algorithm. Dromer O; Alata O; Bernard O Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():6930-3. PubMed ID: 19964459 [TBL] [Abstract][Full Text] [Related]
7. A transform domain SVD filter for suppression of muscle noise artefacts in exercise ECG's. Paul JS; Reddy MR; Kumar VJ IEEE Trans Biomed Eng; 2000 May; 47(5):654-63. PubMed ID: 10851809 [TBL] [Abstract][Full Text] [Related]
8. Removing ECG noise from surface EMG signals using adaptive filtering. Lu G; Brittain JS; Holland P; Yianni J; Green AL; Stein JF; Aziz TZ; Wang S Neurosci Lett; 2009 Oct; 462(1):14-9. PubMed ID: 19559751 [TBL] [Abstract][Full Text] [Related]
9. Waveform estimation techniques for event-related bioelectric signals: a study of performance. Abou-Chadi FE Front Med Biol Eng; 1996; 7(3):221-41. PubMed ID: 8882907 [TBL] [Abstract][Full Text] [Related]
10. Validity of the adaptive filter for accurate measurement of cardiac output in impedance cardiography. Ono T; Yasuda Y; Ito T; Barros AK; Ishida K; Miyamura M; Yoshizawa M; Yambe T Tohoku J Exp Med; 2004 Mar; 202(3):181-91. PubMed ID: 15065644 [TBL] [Abstract][Full Text] [Related]
11. Filtering electrocardiographic signals using an unbiased and normalized adaptive noise reduction system. Wu Y; Rangayyan RM; Zhou Y; Ng SC Med Eng Phys; 2009 Jan; 31(1):17-26. PubMed ID: 18472295 [TBL] [Abstract][Full Text] [Related]
13. The detection of impedance cardiogram characteristic points using wavelet transform. Shyu LY; Lin YS; Liu CP; Hu WC Comput Biol Med; 2004 Mar; 34(2):165-75. PubMed ID: 14972635 [TBL] [Abstract][Full Text] [Related]
14. [Research of adaptive notch filter based on QRD-LS algorithm for power line interference in ECG]. Wang S; Dong J; Guan X Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Oct; 25(5):1044-7. PubMed ID: 19024443 [TBL] [Abstract][Full Text] [Related]
15. An improved windowing technique for heart rate variability power spectrum estimation. Singh D; Vinod K; Saxena SC; Deepak KK J Med Eng Technol; 2005; 29(2):95-101. PubMed ID: 15804859 [TBL] [Abstract][Full Text] [Related]
17. [The method of wavelet transformation used for extracting the characteristic of the exercise ECG]. Ye J; Zheng C; Guo S; Wang L; Huang Y Zhongguo Yi Liao Qi Xie Za Zhi; 1999 Sep; 23(5):268-71. PubMed ID: 12583071 [TBL] [Abstract][Full Text] [Related]
18. [ECG signal preprocessing based on morphological filtering]. Lin Z; Wang J; Lin B Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Apr; 28(2):365-70. PubMed ID: 21604503 [TBL] [Abstract][Full Text] [Related]
19. Continuous monitoring of cardiac output from TCG signals. Keenan DB Biomed Sci Instrum; 2004; 40():343-9. PubMed ID: 15133982 [TBL] [Abstract][Full Text] [Related]
20. [A modified least mean square (LMS) algorithm with variable step-size for an adaptive noise canceller]. Gao H; Niu CM; Wu W Space Med Med Eng (Beijing); 2002 Oct; 15(5):366-8. PubMed ID: 12449145 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]